RGRajul Gupta

Rajul Gupta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajul Gupta has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Incidence, predictive factors, and proposed classification of wound complications in pediatric extremity bone sarcoma patients following extirpative surgery

    by Ayesha A. Qureshi, Catherine C. Kennedy, Rajul Gupta, Michael J. Schroeder, Michael Nieveras, Seraph Han-Yin Lin, Alexander Vasko, Kim A. Bjorklund, Thomas Scharschmidt, Jenny C. Barker


  • Systematic Review of the Effectiveness of Transphyseal Screws for Correction of Coronal Plane Knee Deformities and Meta-analysis of Comparative Studies With Tension Band Plates

    by Rajul Mbbs Gupta, Aakanksha Sriwastwa, Diane Do Low, Saral Mbbs Patel, Viral Jain, Shital N. Parikh

    Background: Coronal-plane knee deformities, both genu varum and genu valgum, are common in pediatric orthopaedics and can be effectively managed in skeletally immature patients with guided growth techniques. Among these, percutaneous epiphysiodesis using transphyseal screws (PETS) and tension band plates (TBP) are widely used, yet their comparative effectiveness remains debated. Methods: A comprehensive search of PubMed, Embase, and Web of Science (January 2004 to January 2025) identified 603 studies. After applying the inclusion criteria, 13 studies (8 noncomparative and 5 comparative) were included in the analysis. Risk of bias was assessed using the ROBINS-I tool, and study quality was evaluated using the MINORS criteria. A frequentist random-effects meta-analysis was conducted to compare correction rates of mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and mechanical axis deviation (MAD). Results: PETS was effective, with correction rates for mLDFA, MPTA, and MAD ranging from 0.64 to 1.3 degrees/month, 0.52 to 0.86 degrees/month, and 1.3 to 3 mm/month, respectively. The meta-analysis showed faster correction with PETS compared to TBP: mLDFA (θ=0.71; P =0.05), MPTA (θ=0.60; P =0.06), and MAD (θ=0.80; P =0.11), although statistical significance was not reached. A meta-analysis of correction speed of mLDFA (θ=0.43; P =0.17) and MPTA (θ=0.6; P =0.06) in idiopathic patients did not show a significant difference, although faster correction with PETS was again observed. Conclusion: PETS is a reliable method for correcting coronal-plane deformities around the knee, with a tendency to achieve faster angular correction than TBP. Given the heterogeneity of included studies, further randomized controlled trials are needed to confirm these findings and guide implant choice based on patient-specific factors. Level of Evidence: Level III.


  • Reverse Total Shoulder Arthroplasty: Preoperative and Postoperative Imaging Findings

    by Rajul Gupta, Aakanksha Sriwastwa, Tim T. Klostermeier, Paul McMillan, Brian M. Grawe, Susan E. Braley

    Accurate imaging assessment of reverse total shoulder implants requires an understanding of implant biomechanics and the expected appearance of the components, as well as the spectrum of complications and modes of implant failure.


  • Radiologist’s Guide to Lumbar Spine Pain Interventions: Indications, Techniques, and Complications

    by Rajul Gupta, Aakanksha Sriwastwa, David Wang, Michael J. Hazenfield

    Knowledge of the pathophysiology of lumbar pain, appropriate patient selection, fluoroscopic anatomy, needle placement, and potential complications is crucial for successful lumbar spine pain interventions.


  • Open Access

    Medical 3D Printing Using Material Jetting: Technology Overview, Medical Applications, and Challenges

    by Shivum Chokshi, Raghav Gangatirkar, Anish Kandi, Maria DeLeonibus, Mohamed Kamel, Seetharam Chadalavada, Rajul Gupta, Harshitha Munigala, Karthik Tappa, Shayne Kondor, et al.

    Material Jetting (MJT) 3D printing (3DP) is a specific technology that deposits photocurable droplets of material and colored inks to fabricate objects layer-by-layer. The high resolution and full color capability render MJT 3DP an ideal technology for 3DP in medicine as evidenced by the 3DP literature. The technology has been adopted globally across the Americas, Europe, Asia, and Australia. While MJT 3D printers can be expensive, their ability to fabricate highly accurate and multi-color parts provides a lucrative opportunity in the creation of advanced prototypes and medical models. The literature on MJT 3DP has expanded greatly as of late, in part aided by the lowering costs of the technology, and this report is the first review to document the applications of MJT in medicine. Additionally, this report portrays the technological information behind MJT 3DP, cases involving fabricated MJT 3DP models from the University of Cincinnati 3DP lab, as well as the challenges of MJT in a clinical setting, including cost, expertise in managing the machines, and scalability issues. It is expected that MJT 3DP, as imaging and segmentation technologies undergo future improvement, will be best poised with representing the voxel-level-variations captured by radiologic-image-sets due to its capacity for voxel-level-control.


  • Comparison of Single-Stage and Dual-Stage Approaches for Nonunion Repair in the Absence of Evident Infections

    by Rajul Mbbs Gupta, Andrew Bs Burkhart, Tyler Bs Barnes, Michael Beltran, Richard Laughlin, Henry Claude Sagi

    OBJECTIVES: The aim of the study was to determine if routine dual-stage nonunion repair (DSR) surgery leads to better outcomes than single-stage nonunion (SSR) repair surgery in fracture nonunions without evident clinical or laboratory signs of infection. METHODS: Design: Retrospective comparison study. Setting: Level 1 Trauma Center affiliated with an academic teaching hospital. Patient Selection Criteria: Skeletally mature patients diagnosed with fracture nonunion between June 2013 and January 2022 were included. Patients with previous nonoperative treatment, definitive external fixation, previous or current diagnosis of fracture-related infection, or P = 0.918; smoking, P = 0.86; lower limb fractures, P = 0.238; diabetes, P = 0.503; erythocyte sedimentation rate, P = 0.27; C-reactive protein, P = 0.11; age, P = 0.11; Charlson comorbidity index, P = 0.06) except for a higher rate of DSR in cases initially treated elsewhere (P = 0.015) and in obese patients (P = 0.044). Bone grafting was more frequent in DSR using plates (P = 0.030). No significant differences were observed in subsequent infections (6.97% vs. 7.41%, P = 0.939), persistent nonunion (28.2% vs. 14.81%, P = 0.169), or implant failure (19.76% vs. 22.22%, P = 0.782) between SSR and DSR. CONCLUSIONS: No difference was found in infection, recalcitrant nonunion, and implant failure between SSR and DSR for nonunions without overt signs of infection. The study challenges the routine use of DSR, questions the necessity of subjecting patients to 2 surgical procedures, and advocates for a more judicious approach in the absence of overt fracture-related infection in a fracture nonunion. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


  • Iatrogenic Common Peroneal Nerve Injuries From Inside-out Lateral Meniscus Repair

    by Rajul Gupta, Nick Lopreiato, Kevin Little, Mohab Foad, Shital N. Parikh

    Cases: We report 2 cases of common peroneal nerve (CPN) palsy after inside-out lateral meniscus (LM) repair with very different presentations, occurring despite the standard surgical precautions (open counter incision and proper retraction between the biceps femoris tendon, lateral gastrocnemius, and capsule). On exploration, needle was found to have penetrated the nerve in one case and the nerve sheath in the other case. Patient 1 had near-complete neurological recovery, while patient 2 had partial neurological recovery after suture removal and neurolysis. Conclusion: CPN palsy can occur despite following all precautions during LM repair and should be managed as an iatrogenic injury unless proven otherwise.


  • Open Access

    Augmented cement shelf acetabuloplasty to improve hip stability in elderly patients with recurrent hemiarthroplasty dislocations

    by Rajul Gupta, Evan Dowell, Toan Theodore Le

    Background: The treatment of dislocated hip hemiarthroplasty in low-demand elderly patients is controversial due to poor results with closed reduction, and significant complications with exchange arthroplasty. This case series demonstrates the use of a novel, simple surgical technique for hip hemiarthroplasty containment without resorting to exchange arthroplasty. Methods: Eleven patients where screw-augmented cement shelf acetabuloplasty procedures were performed were retrospectively identified. All surgeries were performed by a single attending surgeon, at a level-one trauma center, from 2015 to 2022. Previous dislocations, interventions, co-morbidities, mobility level, and posterior wall deficiency were recorded from the patient's charts. The following outcome measures were recorded: operative time, blood loss, perioperative complications, early and late infections, shelf loosening, subsequent dislocations, and the need for additional procedures. Results: The median duration between hip hemiarthroplasty and shelf procedure was 56 days. The mean duration of the surgical procedure was only 63 min, and the mean blood loss was only 250 mL. There was only one instance of loosening of the cement shelf. Two patients had surgical site infections leading to sepsis and death. In two patients, the femoral head was exchanged to improve stability. All patients were allowed immediate weight bearing after the procedure. Conclusions: Shelf acetabuloplasty is a simple, inexpensive, and safe procedure to salvage recurrent hip hemiarthroplasty dislocation in low-demand patients. Shorter surgical duration, relatively lower blood loss, and immediate weight bearing render this an attractive procedure for this fragile population.

  • Musculoskeletal 3D Printing

    by Rajul Gupta, Sean P. Martin, Aakanksha Sriwastwa, Betty Ann Schwarz, Satheesh Krishna, Kirstin M. Small, Leonid L. Chepelev, Adnan Sheikh, Matthew DiPaola

  • Applications of 3D Printing in the Abdomen and Pelvis

    by Shivum Chokshi, David H. Ballard, Rajul Gupta, Seetharam C. Chadalavada, Nicole Wake