Rajul Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rajul Gupta has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Aakanksha Sriwastwa
University of Cincinnati, Cincinnati, US
4 shared publications - Shivum Chokshi
University of Cincinnati College of Medicine
4 shared publications - Adnan Sheikh
Vancouver General Hospital/University of British Columbia
3 shared publications - Prashanth Ravi
Department of Radiology, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA
3 shared publications - Aakanksha Sriwastwa
Department of Radiology (A.S.), University of Cincinnati, Cincinnati, Ohio
2 shared publications - Frank J. Rybicki
Banner University Medical Group & University of Arizona - Phoenix
2 shared publications
Latest Publications
- Open Access
- 25 April 2026
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 61 (8) , 163134
Incidence, predictive factors, and proposed classification of wound complications in pediatric extremity bone sarcoma patients following extirpative surgery
- 25 April 2026
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 61 (8) , 163134
Open AccessIncidence, predictive factors, and proposed classification of wound complications in pediatric extremity bone sarcoma patients following extirpative surgery
- 18 March 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 46 (8) , 511-519
Systematic Review of the Effectiveness of Transphyseal Screws for Correction of Coronal Plane Knee Deformities and Meta-analysis of Comparative Studies With Tension Band Plates
Background: Coronal-plane knee deformities, both genu varum and genu valgum, are common in pediatric orthopaedics and can be effectively managed in skeletally immature patients with guided growth techniques. Among these, percutaneous epiphysiodesis using transphyseal screws (PETS) and tension band plates (TBP) are widely used, yet their comparative effectiveness remains debated. Methods: A comprehensive search of PubMed, Embase, and Web of Science (January 2004 to January 2025) identified 603 studies. After applying the inclusion criteria, 13 studies (8 noncomparative and 5 comparative) were included in the analysis. Risk of bias was assessed using the ROBINS-I tool, and study quality was evaluated using the MINORS criteria. A frequentist random-effects meta-analysis was conducted to compare correction rates of mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and mechanical axis deviation (MAD). Results: PETS was effective, with correction rates for mLDFA, MPTA, and MAD ranging from 0.64 to 1.3 degrees/month, 0.52 to 0.86 degrees/month, and 1.3 to 3 mm/month, respectively. The meta-analysis showed faster correction with PETS compared to TBP: mLDFA (θ=0.71; P =0.05), MPTA (θ=0.60; P =0.06), and MAD (θ=0.80; P =0.11), although statistical significance was not reached. A meta-analysis of correction speed of mLDFA (θ=0.43; P =0.17) and MPTA (θ=0.6; P =0.06) in idiopathic patients did not show a significant difference, although faster correction with PETS was again observed. Conclusion: PETS is a reliable method for correcting coronal-plane deformities around the knee, with a tendency to achieve faster angular correction than TBP. Given the heterogeneity of included studies, further randomized controlled trials are needed to confirm these findings and guide implant choice based on patient-specific factors. Level of Evidence: Level III.
- 18 March 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 46 (8) , 511-519
Systematic Review of the Effectiveness of Transphyseal Screws for Correction of Coronal Plane Knee Deformities and Meta-analysis of Comparative Studies With Tension Band Plates
Background: Coronal-plane knee deformities, both genu varum and genu valgum, are common in pediatric orthopaedics and can be effectively managed in skeletally immature patients with guided growth techniques. Among these, percutaneous epiphysiodesis using transphyseal screws (PETS) and tension band plates (TBP) are widely used, yet their comparative effectiveness remains debated. Methods: A comprehensive search of PubMed, Embase, and Web of Science (January 2004 to January 2025) identified 603 studies. After applying the inclusion criteria, 13 studies (8 noncomparative and 5 comparative) were included in the analysis. Risk of bias was assessed using the ROBINS-I tool, and study quality was evaluated using the MINORS criteria. A frequentist random-effects meta-analysis was conducted to compare correction rates of mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and mechanical axis deviation (MAD). Results: PETS was effective, with correction rates for mLDFA, MPTA, and MAD ranging from 0.64 to 1.3 degrees/month, 0.52 to 0.86 degrees/month, and 1.3 to 3 mm/month, respectively. The meta-analysis showed faster correction with PETS compared to TBP: mLDFA (θ=0.71; P =0.05), MPTA (θ=0.60; P =0.06), and MAD (θ=0.80; P =0.11), although statistical significance was not reached. A meta-analysis of correction speed of mLDFA (θ=0.43; P =0.17) and MPTA (θ=0.6; P =0.06) in idiopathic patients did not show a significant difference, although faster correction with PETS was again observed. Conclusion: PETS is a reliable method for correcting coronal-plane deformities around the knee, with a tendency to achieve faster angular correction than TBP. Given the heterogeneity of included studies, further randomized controlled trials are needed to confirm these findings and guide implant choice based on patient-specific factors. Level of Evidence: Level III.
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (12) , e240251
Reverse Total Shoulder Arthroplasty: Preoperative and Postoperative Imaging Findings
Accurate imaging assessment of reverse total shoulder implants requires an understanding of implant biomechanics and the expected appearance of the components, as well as the spectrum of complications and modes of implant failure.
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (12) , e240251
Reverse Total Shoulder Arthroplasty: Preoperative and Postoperative Imaging Findings
Accurate imaging assessment of reverse total shoulder implants requires an understanding of implant biomechanics and the expected appearance of the components, as well as the spectrum of complications and modes of implant failure.
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (3) , e240188
Radiologist’s Guide to Lumbar Spine Pain Interventions: Indications, Techniques, and Complications
Knowledge of the pathophysiology of lumbar pain, appropriate patient selection, fluoroscopic anatomy, needle placement, and potential complications is crucial for successful lumbar spine pain interventions.
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (3) , e240188
Radiologist’s Guide to Lumbar Spine Pain Interventions: Indications, Techniques, and Complications
Knowledge of the pathophysiology of lumbar pain, appropriate patient selection, fluoroscopic anatomy, needle placement, and potential complications is crucial for successful lumbar spine pain interventions.
- Open Access
- 28 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 249
Medical 3D Printing Using Material Jetting: Technology Overview, Medical Applications, and Challenges
Material Jetting (MJT) 3D printing (3DP) is a specific technology that deposits photocurable droplets of material and colored inks to fabricate objects layer-by-layer. The high resolution and full color capability render MJT 3DP an ideal technology for 3DP in medicine as evidenced by the 3DP literature. The technology has been adopted globally across the Americas, Europe, Asia, and Australia. While MJT 3D printers can be expensive, their ability to fabricate highly accurate and multi-color parts provides a lucrative opportunity in the creation of advanced prototypes and medical models. The literature on MJT 3DP has expanded greatly as of late, in part aided by the lowering costs of the technology, and this report is the first review to document the applications of MJT in medicine. Additionally, this report portrays the technological information behind MJT 3DP, cases involving fabricated MJT 3DP models from the University of Cincinnati 3DP lab, as well as the challenges of MJT in a clinical setting, including cost, expertise in managing the machines, and scalability issues. It is expected that MJT 3DP, as imaging and segmentation technologies undergo future improvement, will be best poised with representing the voxel-level-variations captured by radiologic-image-sets due to its capacity for voxel-level-control.
- 28 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 249
Open AccessMedical 3D Printing Using Material Jetting: Technology Overview, Medical Applications, and Challenges
Material Jetting (MJT) 3D printing (3DP) is a specific technology that deposits photocurable droplets of material and colored inks to fabricate objects layer-by-layer. The high resolution and full color capability render MJT 3DP an ideal technology for 3DP in medicine as evidenced by the 3DP literature. The technology has been adopted globally across the Americas, Europe, Asia, and Australia. While MJT 3D printers can be expensive, their ability to fabricate highly accurate and multi-color parts provides a lucrative opportunity in the creation of advanced prototypes and medical models. The literature on MJT 3DP has expanded greatly as of late, in part aided by the lowering costs of the technology, and this report is the first review to document the applications of MJT in medicine. Additionally, this report portrays the technological information behind MJT 3DP, cases involving fabricated MJT 3DP models from the University of Cincinnati 3DP lab, as well as the challenges of MJT in a clinical setting, including cost, expertise in managing the machines, and scalability issues. It is expected that MJT 3DP, as imaging and segmentation technologies undergo future improvement, will be best poised with representing the voxel-level-variations captured by radiologic-image-sets due to its capacity for voxel-level-control.
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 39 (2) , 41-45
Comparison of Single-Stage and Dual-Stage Approaches for Nonunion Repair in the Absence of Evident Infections
OBJECTIVES: The aim of the study was to determine if routine dual-stage nonunion repair (DSR) surgery leads to better outcomes than single-stage nonunion (SSR) repair surgery in fracture nonunions without evident clinical or laboratory signs of infection. METHODS: Design: Retrospective comparison study. Setting: Level 1 Trauma Center affiliated with an academic teaching hospital. Patient Selection Criteria: Skeletally mature patients diagnosed with fracture nonunion between June 2013 and January 2022 were included. Patients with previous nonoperative treatment, definitive external fixation, previous or current diagnosis of fracture-related infection, or P = 0.918; smoking, P = 0.86; lower limb fractures, P = 0.238; diabetes, P = 0.503; erythocyte sedimentation rate, P = 0.27; C-reactive protein, P = 0.11; age, P = 0.11; Charlson comorbidity index, P = 0.06) except for a higher rate of DSR in cases initially treated elsewhere (P = 0.015) and in obese patients (P = 0.044). Bone grafting was more frequent in DSR using plates (P = 0.030). No significant differences were observed in subsequent infections (6.97% vs. 7.41%, P = 0.939), persistent nonunion (28.2% vs. 14.81%, P = 0.169), or implant failure (19.76% vs. 22.22%, P = 0.782) between SSR and DSR. CONCLUSIONS: No difference was found in infection, recalcitrant nonunion, and implant failure between SSR and DSR for nonunions without overt signs of infection. The study challenges the routine use of DSR, questions the necessity of subjecting patients to 2 surgical procedures, and advocates for a more judicious approach in the absence of overt fracture-related infection in a fracture nonunion. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 February 2025
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 39 (2) , 41-45
Comparison of Single-Stage and Dual-Stage Approaches for Nonunion Repair in the Absence of Evident Infections
OBJECTIVES: The aim of the study was to determine if routine dual-stage nonunion repair (DSR) surgery leads to better outcomes than single-stage nonunion (SSR) repair surgery in fracture nonunions without evident clinical or laboratory signs of infection. METHODS: Design: Retrospective comparison study. Setting: Level 1 Trauma Center affiliated with an academic teaching hospital. Patient Selection Criteria: Skeletally mature patients diagnosed with fracture nonunion between June 2013 and January 2022 were included. Patients with previous nonoperative treatment, definitive external fixation, previous or current diagnosis of fracture-related infection, or P = 0.918; smoking, P = 0.86; lower limb fractures, P = 0.238; diabetes, P = 0.503; erythocyte sedimentation rate, P = 0.27; C-reactive protein, P = 0.11; age, P = 0.11; Charlson comorbidity index, P = 0.06) except for a higher rate of DSR in cases initially treated elsewhere (P = 0.015) and in obese patients (P = 0.044). Bone grafting was more frequent in DSR using plates (P = 0.030). No significant differences were observed in subsequent infections (6.97% vs. 7.41%, P = 0.939), persistent nonunion (28.2% vs. 14.81%, P = 0.169), or implant failure (19.76% vs. 22.22%, P = 0.782) between SSR and DSR. CONCLUSIONS: No difference was found in infection, recalcitrant nonunion, and implant failure between SSR and DSR for nonunions without overt signs of infection. The study challenges the routine use of DSR, questions the necessity of subjecting patients to 2 surgical procedures, and advocates for a more judicious approach in the absence of overt fracture-related infection in a fracture nonunion. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Iatrogenic Common Peroneal Nerve Injuries From Inside-out Lateral Meniscus Repair
Cases: We report 2 cases of common peroneal nerve (CPN) palsy after inside-out lateral meniscus (LM) repair with very different presentations, occurring despite the standard surgical precautions (open counter incision and proper retraction between the biceps femoris tendon, lateral gastrocnemius, and capsule). On exploration, needle was found to have penetrated the nerve in one case and the nerve sheath in the other case. Patient 1 had near-complete neurological recovery, while patient 2 had partial neurological recovery after suture removal and neurolysis. Conclusion: CPN palsy can occur despite following all precautions during LM repair and should be managed as an iatrogenic injury unless proven otherwise.
- 1 October 2024
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 14 (4)
Iatrogenic Common Peroneal Nerve Injuries From Inside-out Lateral Meniscus Repair
Cases: We report 2 cases of common peroneal nerve (CPN) palsy after inside-out lateral meniscus (LM) repair with very different presentations, occurring despite the standard surgical precautions (open counter incision and proper retraction between the biceps femoris tendon, lateral gastrocnemius, and capsule). On exploration, needle was found to have penetrated the nerve in one case and the nerve sheath in the other case. Patient 1 had near-complete neurological recovery, while patient 2 had partial neurological recovery after suture removal and neurolysis. Conclusion: CPN palsy can occur despite following all precautions during LM repair and should be managed as an iatrogenic injury unless proven otherwise.
- Open Access
- 17 June 2024
- Published by SAGE Publications in Journal of Orthopaedics, Trauma and Rehabilitation
- Vol. 32 (1) , 14-21
Augmented cement shelf acetabuloplasty to improve hip stability in elderly patients with recurrent hemiarthroplasty dislocations
Background: The treatment of dislocated hip hemiarthroplasty in low-demand elderly patients is controversial due to poor results with closed reduction, and significant complications with exchange arthroplasty. This case series demonstrates the use of a novel, simple surgical technique for hip hemiarthroplasty containment without resorting to exchange arthroplasty. Methods: Eleven patients where screw-augmented cement shelf acetabuloplasty procedures were performed were retrospectively identified. All surgeries were performed by a single attending surgeon, at a level-one trauma center, from 2015 to 2022. Previous dislocations, interventions, co-morbidities, mobility level, and posterior wall deficiency were recorded from the patient's charts. The following outcome measures were recorded: operative time, blood loss, perioperative complications, early and late infections, shelf loosening, subsequent dislocations, and the need for additional procedures. Results: The median duration between hip hemiarthroplasty and shelf procedure was 56 days. The mean duration of the surgical procedure was only 63 min, and the mean blood loss was only 250 mL. There was only one instance of loosening of the cement shelf. Two patients had surgical site infections leading to sepsis and death. In two patients, the femoral head was exchanged to improve stability. All patients were allowed immediate weight bearing after the procedure. Conclusions: Shelf acetabuloplasty is a simple, inexpensive, and safe procedure to salvage recurrent hip hemiarthroplasty dislocation in low-demand patients. Shorter surgical duration, relatively lower blood loss, and immediate weight bearing render this an attractive procedure for this fragile population.
- 17 June 2024
- Published by SAGE Publications in Journal of Orthopaedics, Trauma and Rehabilitation
- Vol. 32 (1) , 14-21
Open AccessAugmented cement shelf acetabuloplasty to improve hip stability in elderly patients with recurrent hemiarthroplasty dislocations
Background: The treatment of dislocated hip hemiarthroplasty in low-demand elderly patients is controversial due to poor results with closed reduction, and significant complications with exchange arthroplasty. This case series demonstrates the use of a novel, simple surgical technique for hip hemiarthroplasty containment without resorting to exchange arthroplasty. Methods: Eleven patients where screw-augmented cement shelf acetabuloplasty procedures were performed were retrospectively identified. All surgeries were performed by a single attending surgeon, at a level-one trauma center, from 2015 to 2022. Previous dislocations, interventions, co-morbidities, mobility level, and posterior wall deficiency were recorded from the patient's charts. The following outcome measures were recorded: operative time, blood loss, perioperative complications, early and late infections, shelf loosening, subsequent dislocations, and the need for additional procedures. Results: The median duration between hip hemiarthroplasty and shelf procedure was 56 days. The mean duration of the surgical procedure was only 63 min, and the mean blood loss was only 250 mL. There was only one instance of loosening of the cement shelf. Two patients had surgical site infections leading to sepsis and death. In two patients, the femoral head was exchanged to improve stability. All patients were allowed immediate weight bearing after the procedure. Conclusions: Shelf acetabuloplasty is a simple, inexpensive, and safe procedure to salvage recurrent hip hemiarthroplasty dislocation in low-demand patients. Shorter surgical duration, relatively lower blood loss, and immediate weight bearing render this an attractive procedure for this fragile population.
- 19 April 2024
- Published by Springer Nature
- p. 105-125
Musculoskeletal 3D Printing
- 19 April 2024
- Published by Springer Nature
- p. 267-283
Applications of 3D Printing in the Abdomen and Pelvis
- 19 April 2024
- Published by Springer Nature
- p. 267-283
Applications of 3D Printing in the Abdomen and Pelvis