Maria Tucci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maria Tucci has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bartolomeo Trentadue
Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy
2 shared publications - Giuseppe Solarino
Department of Translational Biomedicine and Neuroscience, Università degli studi di Bari Aldo Moro, Bari, Italy
2 shared publications - Mario Ceddia
Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy
2 shared publications - Giorgio Giannini
Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
1 shared publication - Giuseppe De Giosa
Department of Translational Biomedicine and Neuroscience, University of Bari “Aldo Moro”, Policlinic Piazza G. Cesare, 11, 70124 Bari, Italy
1 shared publication - Luciano Lamberti
Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy
1 shared publication
Latest Publications
- Open Access
- 23 August 2024
- Published by MDPI AG in Journal of Composites Science
- Vol. 8 (9) , 334
Stress Analysis of Tibial Bone Using Three Different Materials for Bone Fixation Plates
Stress shielding is a problem for traditional metal bone fixation plates made of magnesium and titanium alloys. This problem can be solved by using composite materials with a low elastic modulus. This study analyzed the effect of carbon fiber reinforced PEEK (CFRP) composites on stress shielding under static loading using finite element simulations. Callus formation times relative to the healing period were gradually imposed according to the elapsed time, considering 1% and 75% as healing stages. The Inventor© 3D CAD 2024 software was used for modeling, and the ANSYS© FEA R2023 software was used for analysis. The results showed that metal fixation plates made of titanium and magnesium alloys transferred less stress to the bone than the CFRP fixation plate. In particular, the use of the CFRP fixation plate resulted in a higher peak stress and a more uniform stress field in the bone, especially in the bone-plate contact area, where the risk of stress shielding is higher in the 1% and 75% healing phases.
- 23 August 2024
- Published by MDPI AG in Journal of Composites Science
- Vol. 8 (9) , 334
Open AccessStress Analysis of Tibial Bone Using Three Different Materials for Bone Fixation Plates
Stress shielding is a problem for traditional metal bone fixation plates made of magnesium and titanium alloys. This problem can be solved by using composite materials with a low elastic modulus. This study analyzed the effect of carbon fiber reinforced PEEK (CFRP) composites on stress shielding under static loading using finite element simulations. Callus formation times relative to the healing period were gradually imposed according to the elapsed time, considering 1% and 75% as healing stages. The Inventor© 3D CAD 2024 software was used for modeling, and the ANSYS© FEA R2023 software was used for analysis. The results showed that metal fixation plates made of titanium and magnesium alloys transferred less stress to the bone than the CFRP fixation plate. In particular, the use of the CFRP fixation plate resulted in a higher peak stress and a more uniform stress field in the bone, especially in the bone-plate contact area, where the risk of stress shielding is higher in the 1% and 75% healing phases.
- Open Access
- 2 July 2024
- Published by MDPI AG in Journal of Composites Science
- Vol. 8 (7) , 254
A Finite Element Analysis Study of Influence of Femoral Stem Material in Stress Shielding in a Model of Uncemented Total Hip Arthroplasty: Ti-6Al-4V versus Carbon Fibre-Reinforced PEEK Composite
Total hip arthroplasty is one of the most common and successful orthopaedic operations. Occasionally, periprosthetic osteolysis associated with stress shielding occurs, resulting in a reduction of bone density where the femur is not properly loaded and the formation of denser bone where stresses are confined. To enhance proximal load transfer and reduce stress shielding, approaches, including decreasing the stiffness of femoral stems, such as carbon fibre-reinforced polymer composites (CFRPCs), have been explored through novel modular prostheses. The purpose of the present study was to analyse, by the finite element analysis (FEA) method, the effect that the variation of material for the distal part of the femoral stem has on stress transmission between a modulable prosthesis and the adjacent bone. Methods: Through three-dimensional modelling and the use of commercially available FEA software Ansys R2023, the mechanical behaviour of the distal part of the femoral stem made of CFRPC or Ti-6Al-4V was obtained. A load was applied to the head of the femoral stem that simulates a complete walking cycle. Results: The results showed that the use of a material with mechanical characteristics close to the bone, like CFRPC, allowed for optimisation of the transmitted loads, promoting a better distribution of stress from the proximal to the distal part of the femur. This observation was also found in some clinical studies in literature, which reported not only an improved load transfer with the use of CFRPC but also a higher cell attachment than Ti-6Al-4V. Conclusions: The use of a material that has mechanical properties that are close to bone promotes load transfer from the proximal to the distal area. In particular, the use of CFRPC allows the material to be designed based on the patient’s actual bone characteristics. This provides a customised design with a lower risk of prosthesis loss due to stress shielding.
- 2 July 2024
- Published by MDPI AG in Journal of Composites Science
- Vol. 8 (7) , 254
Open AccessA Finite Element Analysis Study of Influence of Femoral Stem Material in Stress Shielding in a Model of Uncemented Total Hip Arthroplasty: Ti-6Al-4V versus Carbon Fibre-Reinforced PEEK Composite
Total hip arthroplasty is one of the most common and successful orthopaedic operations. Occasionally, periprosthetic osteolysis associated with stress shielding occurs, resulting in a reduction of bone density where the femur is not properly loaded and the formation of denser bone where stresses are confined. To enhance proximal load transfer and reduce stress shielding, approaches, including decreasing the stiffness of femoral stems, such as carbon fibre-reinforced polymer composites (CFRPCs), have been explored through novel modular prostheses. The purpose of the present study was to analyse, by the finite element analysis (FEA) method, the effect that the variation of material for the distal part of the femoral stem has on stress transmission between a modulable prosthesis and the adjacent bone. Methods: Through three-dimensional modelling and the use of commercially available FEA software Ansys R2023, the mechanical behaviour of the distal part of the femoral stem made of CFRPC or Ti-6Al-4V was obtained. A load was applied to the head of the femoral stem that simulates a complete walking cycle. Results: The results showed that the use of a material with mechanical characteristics close to the bone, like CFRPC, allowed for optimisation of the transmitted loads, promoting a better distribution of stress from the proximal to the distal part of the femur. This observation was also found in some clinical studies in literature, which reported not only an improved load transfer with the use of CFRPC but also a higher cell attachment than Ti-6Al-4V. Conclusions: The use of a material that has mechanical properties that are close to bone promotes load transfer from the proximal to the distal area. In particular, the use of CFRPC allows the material to be designed based on the patient’s actual bone characteristics. This provides a customised design with a lower risk of prosthesis loss due to stress shielding.