Wan-Chen Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wan-Chen Jiang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ying Wang
Dalian Maritime University
3 shared publications - Yuntao Liu
Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China; State Key Laboratory of Traditional Chinese Medicine Syndrome, Guangzhou, Guangdong, China; Chinese Medicine Guangdong Laboratory, Zhuhai, Guangdong, China; Guangdong Provincial Key Laboratory of Research on Emergency in TCM, Guangzhou, Guangdong, China
3 shared publications - Bing Hong
Institute of Energy, Hefei Comprehensive National Science Center, Hefei, China
2 shared publications - Rui Zhang
Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
2 shared publications - Cheng-Hao Yu
Innovation Center for Electronic Design Automation Technology, School of Electronics and Information (School of IC Science and Engineering), Hangzhou Dianzi University, Hangzhou, China
1 shared publication - Haijun Lou
School of Electronics and Information Engineering, Hangzhou Dianzi University, Hangzhou, China
1 shared publication
Latest Publications
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Investigation of the Trench Schottky-Type Neutron Detectors Based on First Principles
In the present study, the thermal neutron detection sensor is fabricated through the integration of fluoride (6LiF) and Silicon Carbide (4H-SiC) as core constituent materials. In order to simulate the thermal oxidation behavior of 4H-SiC under realistic oxidizing conditions, a thermodynamic calculation approach grounded in the first law of thermodynamics was utilized. The simulation indicates that a temperature of 1373 K is optimal for the growth of SiO2 thin films through thermal oxidation. It has been demonstrated that thermal oxidation results in the formation of a SiO2 dielectric layer on the detector surface. This layer has been shown to be effective in suppressing leakage current, thereby ensuring the stable and reliable operation of the detector. The trap states of majority and minority carriers in the 4H-SiC neutron detector were systematically characterized by means of deep level transient spectroscopy. Three distinct trap states were identified at the energy levels of E1, S1, and E0, among which the electron trap E0 is predominant, with a concentration of 1.14e13 cm-3. The experimental results demonstrate that the neutron detection efficiency attains a maximum value of 6.57%. This study provides a comprehensive overview of the experimental and theoretical analyses of the 4H-SiC/SiO2 neutron detector. The study provides theoretical insights into the origins of interface states and identifies potential avenues for future passivation strategies.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Investigation of the Trench Schottky-Type Neutron Detectors Based on First Principles
In the present study, the thermal neutron detection sensor is fabricated through the integration of fluoride (6LiF) and Silicon Carbide (4H-SiC) as core constituent materials. In order to simulate the thermal oxidation behavior of 4H-SiC under realistic oxidizing conditions, a thermodynamic calculation approach grounded in the first law of thermodynamics was utilized. The simulation indicates that a temperature of 1373 K is optimal for the growth of SiO2 thin films through thermal oxidation. It has been demonstrated that thermal oxidation results in the formation of a SiO2 dielectric layer on the detector surface. This layer has been shown to be effective in suppressing leakage current, thereby ensuring the stable and reliable operation of the detector. The trap states of majority and minority carriers in the 4H-SiC neutron detector were systematically characterized by means of deep level transient spectroscopy. Three distinct trap states were identified at the energy levels of E1, S1, and E0, among which the electron trap E0 is predominant, with a concentration of 1.14e13 cm-3. The experimental results demonstrate that the neutron detection efficiency attains a maximum value of 6.57%. This study provides a comprehensive overview of the experimental and theoretical analyses of the 4H-SiC/SiO2 neutron detector. The study provides theoretical insights into the origins of interface states and identifies potential avenues for future passivation strategies.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Comparative Study of SiC Microstructure Neutron Detectors
In order to meet the demand for neutron detection in extreme environments with high temperature, high pressure and strong radiation, different Schottky-type microstructure neutron detectors based on the wide band gap semiconductor material 4H-SiC are designed in this work. Detectors D1 and D2 used nickel (Ni) and high melting point tungsten (W) as the front Schottky contact electrode metals, respectively, while detector D3 added a silicon dioxide (SiO 2 ) interlayer at the W metal-semiconductor interface. Current-voltage measurements show that the detectors D1, D2 and D3 have typical Schottky rectification characteristics. The transient current pulse response of the detectors is affected by different applied bias voltages and incident particle energies. At room temperature, the detector D3 with SiO 2 interlayer shows the highest neutron detection efficiency of 6.57%. It also demonstrates that the SiO 2 interlayer can reduce the leakage current due to high surface states and surface damage generated during process fabrication. The neutron irradiation of the detectors at high temperature (150 °C) is also studied, and very small differences in the energy spectra of the detectors are observed compared to those in a room-temperature environment, demonstrating that the 4H-SiC based Schottky-type microstructure neutron detectors have the capability of detecting neutrons at high temperatures as well.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Comparative Study of SiC Microstructure Neutron Detectors
In order to meet the demand for neutron detection in extreme environments with high temperature, high pressure and strong radiation, different Schottky-type microstructure neutron detectors based on the wide band gap semiconductor material 4H-SiC are designed in this work. Detectors D1 and D2 used nickel (Ni) and high melting point tungsten (W) as the front Schottky contact electrode metals, respectively, while detector D3 added a silicon dioxide (SiO 2 ) interlayer at the W metal-semiconductor interface. Current-voltage measurements show that the detectors D1, D2 and D3 have typical Schottky rectification characteristics. The transient current pulse response of the detectors is affected by different applied bias voltages and incident particle energies. At room temperature, the detector D3 with SiO 2 interlayer shows the highest neutron detection efficiency of 6.57%. It also demonstrates that the SiO 2 interlayer can reduce the leakage current due to high surface states and surface damage generated during process fabrication. The neutron irradiation of the detectors at high temperature (150 °C) is also studied, and very small differences in the energy spectra of the detectors are observed compared to those in a room-temperature environment, demonstrating that the 4H-SiC based Schottky-type microstructure neutron detectors have the capability of detecting neutrons at high temperatures as well.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Study on 4H-SiC Trench Schottky-Type Neutron Detector
In this paper, a trench Schottky barrier diode structure based on a wide band-gap, high temperature and irradiation resistant 4H-SiC material is innovatively proposed, and the neutron conversion material 6 LiF is filled into the trench array to make a neutron detector. The detector increases both the amount of 6 LiF filling and the total contact area between 6 LiF and the semiconductor material 4H-SiC by etching out the trenches. The neutron response experimental study revealed that the count rate of the detector is as high as 580 cps, corresponding to a detection efficiency of 6.57%, which breaks through the limitation that the detection efficiency of thin-film coated type detectors is less than 5%, which is one of the main contributions of the detector. The utilization of refractory metal tungsten (W) as the frontal Schottky contact electrode enables the detector to maintain a count rate of approximately 100 cps at 180 °C, which indicates that there exists a possibility that the detector can work in high temperature environments, and also provides experimental basis for the development of high temperature resistant neutron detectors.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Study on 4H-SiC Trench Schottky-Type Neutron Detector
In this paper, a trench Schottky barrier diode structure based on a wide band-gap, high temperature and irradiation resistant 4H-SiC material is innovatively proposed, and the neutron conversion material 6 LiF is filled into the trench array to make a neutron detector. The detector increases both the amount of 6 LiF filling and the total contact area between 6 LiF and the semiconductor material 4H-SiC by etching out the trenches. The neutron response experimental study revealed that the count rate of the detector is as high as 580 cps, corresponding to a detection efficiency of 6.57%, which breaks through the limitation that the detection efficiency of thin-film coated type detectors is less than 5%, which is one of the main contributions of the detector. The utilization of refractory metal tungsten (W) as the frontal Schottky contact electrode enables the detector to maintain a count rate of approximately 100 cps at 180 °C, which indicates that there exists a possibility that the detector can work in high temperature environments, and also provides experimental basis for the development of high temperature resistant neutron detectors.