Zeyuan Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zeyuan Duan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Liejin Guo
2 shared publicationsQiang Xu
2 shared publications- Xuanxiang Zhao
State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University , Xi'an 710049
2 shared publications - Yonglu She
State Key Laboratory of Multiphase Flow in Power Engineering
2 shared publications Yujiang Zeng
2 shared publicationsJinfeng Li
1 shared publication
Latest Publications
- Open Access
- 27 May 2026
- Published by Elsevier in SSRN Electronic Journal
Near-Wall Bubble Dynamics in Water Electrolysis on Vertical Dual Microelectrodes
Bubble coverage during hydrogen evolution in water electrolysis reduces the effective reaction area and increases interfacial resistance. Promoting early bubble detachment through coalescence is therefore an important strategy for enhancing electrolysis performance. In this work, a microscale vertical dual platinum-wire microelectrode system capable of stable and independently controlled bubble generation was established to investigate the near-wall dynamics of coalesced bubbles under different overall voltages and inter-electrode voltage difference. Three typical post-coalescence modes were identified, namely direct-detachment bubble (DDB), detachment-return bubble (DRB), and non-detachment bubble (NDB). The dominant mode was found to change sequentially from DDB to DRB and finally to NDB as the overall applied voltage increased or the inter-electrode voltage asymmetry became stronger. In the DDB regime, the maximum wall-normal jumping distance followed a 3/2 power-law scaling with the departure radius. Based on the geometric relation between the post-coalescence bubble and newly generated bubbles in the near-wall region, together with the competition of characteristic time scales, a critical current model was established for the DDB/DRB transition. An energy-based criterion incorporating Marangoni effects was further proposed for the DRB/NDB transition. Compared with horizontal dual-electrode and single-electrode systems, the vertical dual-electrode configuration more effectively promoted coalescence-induced detachment and suppressed repeated near-wall interactions, thereby yielding a higher average current and a shorter detachment period. This work provides new physical insight into bubble regulation at gas-evolving electrochemical interfaces and provides guidance for optimizing electrode configurations.
- 27 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNear-Wall Bubble Dynamics in Water Electrolysis on Vertical Dual Microelectrodes
Bubble coverage during hydrogen evolution in water electrolysis reduces the effective reaction area and increases interfacial resistance. Promoting early bubble detachment through coalescence is therefore an important strategy for enhancing electrolysis performance. In this work, a microscale vertical dual platinum-wire microelectrode system capable of stable and independently controlled bubble generation was established to investigate the near-wall dynamics of coalesced bubbles under different overall voltages and inter-electrode voltage difference. Three typical post-coalescence modes were identified, namely direct-detachment bubble (DDB), detachment-return bubble (DRB), and non-detachment bubble (NDB). The dominant mode was found to change sequentially from DDB to DRB and finally to NDB as the overall applied voltage increased or the inter-electrode voltage asymmetry became stronger. In the DDB regime, the maximum wall-normal jumping distance followed a 3/2 power-law scaling with the departure radius. Based on the geometric relation between the post-coalescence bubble and newly generated bubbles in the near-wall region, together with the competition of characteristic time scales, a critical current model was established for the DDB/DRB transition. An energy-based criterion incorporating Marangoni effects was further proposed for the DRB/NDB transition. Compared with horizontal dual-electrode and single-electrode systems, the vertical dual-electrode configuration more effectively promoted coalescence-induced detachment and suppressed repeated near-wall interactions, thereby yielding a higher average current and a shorter detachment period. This work provides new physical insight into bubble regulation at gas-evolving electrochemical interfaces and provides guidance for optimizing electrode configurations.
- 14 May 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 240
Effect of electrode diameter on H2 bubble dynamics at platinum microelectrodes
- 14 May 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 240
Effect of electrode diameter on H2 bubble dynamics at platinum microelectrodes
- 9 February 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (6)
Dynamics of hydrogen bubble movement and oscillation on platinum microelectrodes during water electrolysis
Insight into the evolution and movement of bubbles during water electrolysis is crucial to promoting bubble detachment. Here, we investigate the dynamics of hydrogen bubble oscillation on a platinum microelectrode by varying electrolyte species and concentration. The electrolyte series favorable for bubble oscillation is identified as H2SO4 > HCl ≈ HNO3 > HClO4. This series exhibits different bubble evolution modes, from bubble oscillation in sulfuric acid to monotonous growth in perchloric acid. Using the positive feedback relationship between displacement and current, differential equations for bubble motion are established, accurately predicting experimental bubble displacement and oscillation. In the growth controlled by the electrochemical reaction rate, buoyancy drives a linear increase in the oscillation equilibrium position over time. The exponential increase in amplitude arises from the negative damping mechanism induced by the bubble motion and reaction rate. The critical period for bubble oscillation is determined, enabling quantification of the oscillation propensity.
- 9 February 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (6)
Dynamics of hydrogen bubble movement and oscillation on platinum microelectrodes during water electrolysis
Insight into the evolution and movement of bubbles during water electrolysis is crucial to promoting bubble detachment. Here, we investigate the dynamics of hydrogen bubble oscillation on a platinum microelectrode by varying electrolyte species and concentration. The electrolyte series favorable for bubble oscillation is identified as H2SO4 > HCl ≈ HNO3 > HClO4. This series exhibits different bubble evolution modes, from bubble oscillation in sulfuric acid to monotonous growth in perchloric acid. Using the positive feedback relationship between displacement and current, differential equations for bubble motion are established, accurately predicting experimental bubble displacement and oscillation. In the growth controlled by the electrochemical reaction rate, buoyancy drives a linear increase in the oscillation equilibrium position over time. The exponential increase in amplitude arises from the negative damping mechanism induced by the bubble motion and reaction rate. The critical period for bubble oscillation is determined, enabling quantification of the oscillation propensity.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 076501
In Situ Observation and Electrical Signal Analysis of Different Bubble Detachment Modes on Microelectrode Surface
The deactivation of the reaction surface caused by bubble covering is an important factor that causes the decrease in the efficiency of water electrolysis. By combining an electrochemical workstation with a high-speed camera, the evolutionary properties of hydrogen bubble and potential were obtained on a horizontal microelectrode with a diameter of 100 μm. During the electrolysis, individual bubbles evolved periodically on the electrode surface. Under the influence of electrode adsorption, the detachment diameter of the bubble is independent of current density, but with the increase of current density, the bubble detachment frequency increases. With the increase of ethylene glycol (EG) concentration, the bubble detachment frequency increased. When the concentration of EG is greater than 7.5 g l−1, the surface tension of the solution is lower than that of water, at which time the detachment mode of the bubble changes. Separating the resistance caused by the bubbles from the total resistance, it was found that the additional resistance caused by the bubbles rapidly became smaller as the EG concentration increased until the EG concentration reached 7.5 g l−1. The total resistance decreases first and then increases when the EG concentration is greater than 3 g l−1.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 076501
In Situ Observation and Electrical Signal Analysis of Different Bubble Detachment Modes on Microelectrode Surface
The deactivation of the reaction surface caused by bubble covering is an important factor that causes the decrease in the efficiency of water electrolysis. By combining an electrochemical workstation with a high-speed camera, the evolutionary properties of hydrogen bubble and potential were obtained on a horizontal microelectrode with a diameter of 100 μm. During the electrolysis, individual bubbles evolved periodically on the electrode surface. Under the influence of electrode adsorption, the detachment diameter of the bubble is independent of current density, but with the increase of current density, the bubble detachment frequency increases. With the increase of ethylene glycol (EG) concentration, the bubble detachment frequency increased. When the concentration of EG is greater than 7.5 g l−1, the surface tension of the solution is lower than that of water, at which time the detachment mode of the bubble changes. Separating the resistance caused by the bubbles from the total resistance, it was found that the additional resistance caused by the bubbles rapidly became smaller as the EG concentration increased until the EG concentration reached 7.5 g l−1. The total resistance decreases first and then increases when the EG concentration is greater than 3 g l−1.