Mercè Torra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mercè Torra has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Diana Rodríguez-Espinosa
Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), 08036 Barcelona, Spain
3 shared publications - Elena Cuadrado-Payán
Nephrology and Renal Transplantation, Hospital Clínic de Barcelona, 08036 Barcelona, Spain
3 shared publications - Francisco Maduell
Hospital Clinic de Barcelona, Barcelona, Spain
3 shared publications - Gregori Casals
Biochemistry and Molecular Genetics Department, Hospital Clínic of Barcelona, Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), 08036 Barcelona, Spain
3 shared publications - José Jesús Broseta
Department of Nephrology and Renal Transplantation, Hospital Clínic of Barcelona, Barcelona, Spain
3 shared publications - María Rodríguez-García
Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Center (CDB), Hospital Clínic of Barcelona, 08036 Barcelona, Spain
3 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Wolters Kluwer Health in Hepatology Communications
- Vol. 10 (10)
Genetic testing and exchangeable copper can improve the accuracy of Wilson disease diagnoses
Was not provided for this article.
- 18 September 2026
- Published by Wolters Kluwer Health in Hepatology Communications
- Vol. 10 (10)
Open AccessGenetic testing and exchangeable copper can improve the accuracy of Wilson disease diagnoses
Was not provided for this article.
- Open Access
Comparative Effects of Acetate- and Citrate-Based Dialysates on Dialysis Dose and Protein-Bound Uremic Toxins in Hemodiafiltration Patients: Exploring the Impact of Calcium and Magnesium Concentrations
Modern hemodialysis employs weak acids as buffers to prevent bicarbonate precipitation with calcium or magnesium. Acetate, the most used acid, is linked to chronic inflammation and poor dialysis tolerance. Citrate has emerged as a potential alternative, though its effect on dialysis efficiency is not clear. This study aims to compare the efficacy of acetate- and citrate-based dialysates, focusing on protein-bound uremic toxins and dialysis doses. This single-center prospective crossover study includes prevalent patients participating in a thrice-weekly online hemodiafiltration program. Four dialysates were tested: two acetate-based (1.25 and 1.5 mmol/L calcium) and two citrate-based (1.5 mmol/L calcium with 0.5 and 0.75 mmol/L magnesium). Pre- and post-dialysis blood samples of eighteen patients were analyzed for urea, creatinine, p-cresyl sulfate, indoxyl sulfate, and albumin. Statistical significance was assessed using paired t-tests and repeated measures of ANOVA. There were no significant differences in dialysis dose (Kt), urea, creatinine, or indoxyl sulfate reduction ratios between acetate- and citrate-based dialysates. However, a significant decrease in the reduction ratio of p-cresyl sulfate was observed with the acetate dialysate containing 1.25 mmol/L calcium and the citrate dialysate with 0.5 mmol/L magnesium compared to the acetate dialysate containing 1.5 mmol/L calcium and the citrate dialysate with 0.75 mmol/L magnesium (51.56 ± 4.75 and 53.02 ± 4.52 vs. 65.25 ± 3.38 and 58.66 ± 4.16, p 0.007). No differences in dialysis dose were found between acetate- and citrate-based dialysates. However, citrate dialysates with lower calcium and magnesium concentrations may reduce the albumin displacement of p-cresyl sulfate. Further studies are needed to understand the observed differences and optimize the dialysate composition for the better clearance of protein-bound uremic toxins.
Open AccessComparative Effects of Acetate- and Citrate-Based Dialysates on Dialysis Dose and Protein-Bound Uremic Toxins in Hemodiafiltration Patients: Exploring the Impact of Calcium and Magnesium Concentrations
Modern hemodialysis employs weak acids as buffers to prevent bicarbonate precipitation with calcium or magnesium. Acetate, the most used acid, is linked to chronic inflammation and poor dialysis tolerance. Citrate has emerged as a potential alternative, though its effect on dialysis efficiency is not clear. This study aims to compare the efficacy of acetate- and citrate-based dialysates, focusing on protein-bound uremic toxins and dialysis doses. This single-center prospective crossover study includes prevalent patients participating in a thrice-weekly online hemodiafiltration program. Four dialysates were tested: two acetate-based (1.25 and 1.5 mmol/L calcium) and two citrate-based (1.5 mmol/L calcium with 0.5 and 0.75 mmol/L magnesium). Pre- and post-dialysis blood samples of eighteen patients were analyzed for urea, creatinine, p-cresyl sulfate, indoxyl sulfate, and albumin. Statistical significance was assessed using paired t-tests and repeated measures of ANOVA. There were no significant differences in dialysis dose (Kt), urea, creatinine, or indoxyl sulfate reduction ratios between acetate- and citrate-based dialysates. However, a significant decrease in the reduction ratio of p-cresyl sulfate was observed with the acetate dialysate containing 1.25 mmol/L calcium and the citrate dialysate with 0.5 mmol/L magnesium compared to the acetate dialysate containing 1.5 mmol/L calcium and the citrate dialysate with 0.75 mmol/L magnesium (51.56 ± 4.75 and 53.02 ± 4.52 vs. 65.25 ± 3.38 and 58.66 ± 4.16, p 0.007). No differences in dialysis dose were found between acetate- and citrate-based dialysates. However, citrate dialysates with lower calcium and magnesium concentrations may reduce the albumin displacement of p-cresyl sulfate. Further studies are needed to understand the observed differences and optimize the dialysate composition for the better clearance of protein-bound uremic toxins.
- 24 September 2024
- Published by Wolters Kluwer Health in Hepatology
- Vol. 81 (6) , 1728-1739
Exchangeable copper for patients with Wilson disease at follow-up: Rethinking normal ranges or changing methodology
Determining suitable copper parameters for monitoring Wilson disease remains a topic of ongoing discussion. International recommendations currently rely on the combination of urinary copper excretion and non-specific liver markers when considering therapy and time elapsed since diagnosis. The emergence of exchangeable copper (CuEX) as a novel measurement reflecting the “free copper pool” held promise as a valuable target to ensure metabolic stability during follow-up, although validation of target ranges remain unknown. We aimed at evaluating CuEX quantification in repeated samples from 92 real-world WD patients during a 2-year period. Patients were classified as “stable” if diagnosis had been made more than one year before and were compliant to stable anti-copper drug and dose. Otherwise, patients were classified as “non-stable”. Two-hundred and thirteen CuEX samples were obtained per clinical practice. Overall, 57% of CuEX measurements fell below the reference “range of normality”, whereas only 34% were within and 9% were above normal levels. There was no association of CuEX levels with therapy, elapsed time from diagnosis or clinical stability, although most of the samples above normality corresponded to non-stable patients. Only 23.4% of the CuEX samples were aligned with data obtained from concomitant urinary copper excretion. Our findings suggest that CuEX is a suboptimal tool for assessing copper homeostasis when used alone and should be used with caution if no additional information is available. Normal reference intervals for WD-treated patients should be redefined, as most of CuEX quantifications fell in the lower range, with no sign of overtreatment in these patients. Export
- 24 September 2024
- Published by Wolters Kluwer Health in Hepatology
- Vol. 81 (6) , 1728-1739
Exchangeable copper for patients with Wilson disease at follow-up: Rethinking normal ranges or changing methodology
Determining suitable copper parameters for monitoring Wilson disease remains a topic of ongoing discussion. International recommendations currently rely on the combination of urinary copper excretion and non-specific liver markers when considering therapy and time elapsed since diagnosis. The emergence of exchangeable copper (CuEX) as a novel measurement reflecting the “free copper pool” held promise as a valuable target to ensure metabolic stability during follow-up, although validation of target ranges remain unknown. We aimed at evaluating CuEX quantification in repeated samples from 92 real-world WD patients during a 2-year period. Patients were classified as “stable” if diagnosis had been made more than one year before and were compliant to stable anti-copper drug and dose. Otherwise, patients were classified as “non-stable”. Two-hundred and thirteen CuEX samples were obtained per clinical practice. Overall, 57% of CuEX measurements fell below the reference “range of normality”, whereas only 34% were within and 9% were above normal levels. There was no association of CuEX levels with therapy, elapsed time from diagnosis or clinical stability, although most of the samples above normality corresponded to non-stable patients. Only 23.4% of the CuEX samples were aligned with data obtained from concomitant urinary copper excretion. Our findings suggest that CuEX is a suboptimal tool for assessing copper homeostasis when used alone and should be used with caution if no additional information is available. Normal reference intervals for WD-treated patients should be redefined, as most of CuEX quantifications fell in the lower range, with no sign of overtreatment in these patients. Export
- Open Access
- 3 August 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (15) , 8491
Citrate Dialysate with and without Magnesium Supplementation in Hemodiafiltration: A Comparative Study Versus Acetate
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative because of its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysates (CDs) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (ADs). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). The following four dialysates were compared: two acetate-based and two citrate-based. Calcium, magnesium, iPTH, iron, selenium, cadmium, copper, zinc, BUN, albumin, creatinine, bicarbonate, and pH were monitored before and after each dialysis session. Seventy-two HDF sessions were performed on eighteen patients. The CDs showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CDs prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. CDs, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations. Until then, given our results, we recommend that when a CD is used, it should be used with a 0.75 mmol/L Mg concentration rather than a 0.5 mmol/L one.
- 3 August 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (15) , 8491
Open AccessCitrate Dialysate with and without Magnesium Supplementation in Hemodiafiltration: A Comparative Study Versus Acetate
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative because of its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysates (CDs) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (ADs). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). The following four dialysates were compared: two acetate-based and two citrate-based. Calcium, magnesium, iPTH, iron, selenium, cadmium, copper, zinc, BUN, albumin, creatinine, bicarbonate, and pH were monitored before and after each dialysis session. Seventy-two HDF sessions were performed on eighteen patients. The CDs showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CDs prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. CDs, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations. Until then, given our results, we recommend that when a CD is used, it should be used with a 0.75 mmol/L Mg concentration rather than a 0.5 mmol/L one.
- Open Access
- 3 July 2024
- Published by MDPI AG in Preprints.org
Citrate Dialysate with and without Magnesium Supplementation in Hemodiafiltration: A Comparative Study versus Acetate
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative due to its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysate (CD) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (AD). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). Four dialysates were compared: two acetate-based and two citrate-based. Various biochemical parameters were monitored before and after each dialysis session. Seventy-two HDF sessions were performed in eighteen patients. CD showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CD prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. Citrate dialysates, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations.
- 3 July 2024
- Published by MDPI AG in Preprints.org
Open AccessCitrate Dialysate with and without Magnesium Supplementation in Hemodiafiltration: A Comparative Study versus Acetate
The choice of dialysate buffer in hemodialysis is crucial, with acetate being widely used despite complications. Citrate has emerged as an alternative due to its favorable effects, yet concerns persist about its impact on calcium and magnesium levels. This study investigates the influence of citrate dialysate (CD) with and without additional magnesium supplementation on CKD-MBD biomarkers and assesses their ability to chelate divalent metals compared to acetate dialysates (AD). A prospective crossover study was conducted in a single center, involving patients on thrice-weekly online hemodiafiltration (HDF). Four dialysates were compared: two acetate-based and two citrate-based. Various biochemical parameters were monitored before and after each dialysis session. Seventy-two HDF sessions were performed in eighteen patients. CD showed stability in iPTH levels and reduced post-dialysis total calcium, with no significant increase in adverse events. Magnesium supplementation with CD prevented hypomagnesemia. However, no significant differences among dialysates were observed in the chelation of other divalent metals. Citrate dialysates, particularly with higher magnesium concentrations, offer promising benefits, including prevention of hypomagnesemia and stabilization of CKD-MBD parameters, suggesting citrate as a viable alternative to acetate. Further studies are warranted to elucidate long-term outcomes and optimize dialysate formulations.
- 1 November 2021
- Published by SAGE Publications in Isokinetics and Exercise Science
- Vol. 29 (4) , 379-385
Detection of effort maximality in adults performing isokinetic wrist flexion and extension
BACKGROUND: The difference between isokinetic eccentric to concentric strength ratios at high and low velocities (DEC) is a powerful tool for identifying submaximal effort in other muscle groups but its efficiency in terms of the wrist extensors (WE) and flexors (WF) isokinetic effort has hitherto not been studied. OBJECTIVE: The objective of the present study is to examine the usefulness of the DEC for identifying suboptimal wrist extensor and flexor isokinetic efforts. METHODS: Twenty healthy male volunteers aged 20–40 years (28.5 [ ] 3.2) were recruited. Participants were instructed to exert maximal and feigned efforts, using a range of motion of 20[ ] in concentric (C) and eccentric (E) WE and WF modes at two velocities: 10 and 40[ ]/s. E/C ratios (E/CR) where then calculated and finally DEC by subtracting low velocity E/CR from high velocity ones. RESULTS: Feigned maximal effort DEC values were significantly higher than their maximal effort counterparts, both for WF and WE. For both actions, a DEC cutoff level to detect submaximal effort could be defined. The sensitivity of the DEC was 71.43% and 62.5% for WE ad WF respectively. The specificity was 100% in both cases. CONCLUSION: The DEC may be a valuable parameter for detecting feigned maximal WF and WE isokinetic effort in healthy adults.
- 1 November 2021
- Published by SAGE Publications in Isokinetics and Exercise Science
- Vol. 29 (4) , 379-385
Detection of effort maximality in adults performing isokinetic wrist flexion and extension
BACKGROUND: The difference between isokinetic eccentric to concentric strength ratios at high and low velocities (DEC) is a powerful tool for identifying submaximal effort in other muscle groups but its efficiency in terms of the wrist extensors (WE) and flexors (WF) isokinetic effort has hitherto not been studied. OBJECTIVE: The objective of the present study is to examine the usefulness of the DEC for identifying suboptimal wrist extensor and flexor isokinetic efforts. METHODS: Twenty healthy male volunteers aged 20–40 years (28.5 [ ] 3.2) were recruited. Participants were instructed to exert maximal and feigned efforts, using a range of motion of 20[ ] in concentric (C) and eccentric (E) WE and WF modes at two velocities: 10 and 40[ ]/s. E/C ratios (E/CR) where then calculated and finally DEC by subtracting low velocity E/CR from high velocity ones. RESULTS: Feigned maximal effort DEC values were significantly higher than their maximal effort counterparts, both for WF and WE. For both actions, a DEC cutoff level to detect submaximal effort could be defined. The sensitivity of the DEC was 71.43% and 62.5% for WE ad WF respectively. The specificity was 100% in both cases. CONCLUSION: The DEC may be a valuable parameter for detecting feigned maximal WF and WE isokinetic effort in healthy adults.