Jiyuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiyuan Liu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Chunjie Zhang
School of Architecture and Fine Art, Dalian University of Technology, Dalian 116023, China
2 shared publications - Feipeng Jiao
School of Architecture and Fine Art, Dalian University of Technology, Dalian 116024, China
2 shared publications - Guopeng Li
School of Architecture and Fine Art, Dalian University of Technology, Dalian 116024, China
2 shared publications
Latest Publications
- Open Access
Study on the Coupling of Air-Source Heat Pumps (ASHPs) and Passive Heating in Cold Regions
Air-source heat pumps (ASHPs), as an active device, are widely used in building heating and cooling processes. However, in severe cold regions, they face reduced heating efficiency and frosting problems in winter. This paper proposes a new heating solution by coupling an ASHP with passive heating systems. It combines an ASHP with passive sunrooms and heat storage systems for heating. Through software simulations and mathematical modeling, the new scheme is compared and analyzed against traditional ASHP solutions to explore the performance of this scheme in rural houses in severe cold regions of China during winter. According to simulation and calculation analysis, on the coldest day of winter, the coupling scheme can provide approximately 99.41 kWh of heat to the indoors, which exceeds the 86.67 kWh required to maintain an indoor temperature of 20 °C. The system’s power consumption is 36.96 kWh, which is 66.88% lower than that of traditional heat pump heating. The study shows that the coupling system of an ASHP and passive heating has a good heating effect in severe cold regions. For the situation of insufficient solar energy at night, the design of phase-change materials and heat storage media can meet heating needs throughout the day.
Open AccessStudy on the Coupling of Air-Source Heat Pumps (ASHPs) and Passive Heating in Cold Regions
Air-source heat pumps (ASHPs), as an active device, are widely used in building heating and cooling processes. However, in severe cold regions, they face reduced heating efficiency and frosting problems in winter. This paper proposes a new heating solution by coupling an ASHP with passive heating systems. It combines an ASHP with passive sunrooms and heat storage systems for heating. Through software simulations and mathematical modeling, the new scheme is compared and analyzed against traditional ASHP solutions to explore the performance of this scheme in rural houses in severe cold regions of China during winter. According to simulation and calculation analysis, on the coldest day of winter, the coupling scheme can provide approximately 99.41 kWh of heat to the indoors, which exceeds the 86.67 kWh required to maintain an indoor temperature of 20 °C. The system’s power consumption is 36.96 kWh, which is 66.88% lower than that of traditional heat pump heating. The study shows that the coupling system of an ASHP and passive heating has a good heating effect in severe cold regions. For the situation of insufficient solar energy at night, the design of phase-change materials and heat storage media can meet heating needs throughout the day.
- Open Access
- 3 July 2024
- Published by MDPI AG in Preprints.org
Study on the Coupling of Air Source Heat Pumps (ASHP) and Passive Heating in Cold Regions
As an active device, air source heat pumps (ASHP) are widely used for heating and cooling in buildings. However, in cold regions, their efficiency decreases, and frost formation becomes a significant issue during winter. This paper proposes a new scheme that couples air source heat pumps with passive heating. By using software simulations and mathematical models, the new scheme is compared to traditional ASHP systems to analyze its heating performance in rural homes during winter in China’s cold regions. According to the simulation and calculation analysis, on the coldest day of winter, the coupling scheme can provide approximately 99.41kWh of heat to the interior, surpassing the 86.67kWh required to maintain an indoor temperature of 20℃. The system’s power consumption is 36.96 kWh, which is 66.88% lower than that of traditional heat pump heating. The study shows that a coupled system of air source heat pumps and passive heating has better heating performance in cold regions. By incorporating phase change materials and heat storage media to address the shortage of solar energy at night, the system can meet the heating needs throughout the entire day.
- 3 July 2024
- Published by MDPI AG in Preprints.org
Open AccessStudy on the Coupling of Air Source Heat Pumps (ASHP) and Passive Heating in Cold Regions
As an active device, air source heat pumps (ASHP) are widely used for heating and cooling in buildings. However, in cold regions, their efficiency decreases, and frost formation becomes a significant issue during winter. This paper proposes a new scheme that couples air source heat pumps with passive heating. By using software simulations and mathematical models, the new scheme is compared to traditional ASHP systems to analyze its heating performance in rural homes during winter in China’s cold regions. According to the simulation and calculation analysis, on the coldest day of winter, the coupling scheme can provide approximately 99.41kWh of heat to the interior, surpassing the 86.67kWh required to maintain an indoor temperature of 20℃. The system’s power consumption is 36.96 kWh, which is 66.88% lower than that of traditional heat pump heating. The study shows that a coupled system of air source heat pumps and passive heating has better heating performance in cold regions. By incorporating phase change materials and heat storage media to address the shortage of solar energy at night, the system can meet the heating needs throughout the entire day.