C. M. Hefferan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
C. M. Hefferan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Robert M. Suter
Department of Physics Carnegie Mellon University 5000 Forbes Avenue 15213 Pittsburgh PA USA
2 shared publications - Shiu Fai Li
Lawrence Livermore National Laboratory
2 shared publications - Brian Tieman
Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 6439, USA
1 shared publication - C. Xiao
Department of Physics, Carnegie Mellon University, Pittsburgh, PA 15213
1 shared publication - Daniel Hennessy
Department of Physics, Carnegie Mellon University, Pittsburgh, PA 15213
1 shared publication J. Lind
Carnegie Mellon University
1 shared publication
Latest Publications
- 1 June 2010
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 25 (2) , 132-137
Tests of microstructure reconstruction by forward modeling of high energy X-ray diffraction microscopy data
Verification tests of the forward modeling technique for near-field high energy X-ray diffraction microscopy are conducted using two simulated microstructures containing uniformly distributed orientations. Comparison between the simulated and reconstructed microstructures is examined with consideration to both crystallographic orientation and spatial geometric accuracy. To probe the dependence of results on experimental parameters, simulated data sets use two different detector configurations and different simulated experimental protocols; in each case, the parameters mimic the experimental geometry used at Advanced Photon Source beamline 1-ID. Results indicate that element orientations are distinguishable to less than 0.1°, while spatial geometric accuracy is limited by the detector resolution.
- 1 June 2010
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 25 (2) , 132-137
Tests of microstructure reconstruction by forward modeling of high energy X-ray diffraction microscopy data
Verification tests of the forward modeling technique for near-field high energy X-ray diffraction microscopy are conducted using two simulated microstructures containing uniformly distributed orientations. Comparison between the simulated and reconstructed microstructures is examined with consideration to both crystallographic orientation and spatial geometric accuracy. To probe the dependence of results on experimental parameters, simulated data sets use two different detector configurations and different simulated experimental protocols; in each case, the parameters mimic the experimental geometry used at Advanced Photon Source beamline 1-ID. Results indicate that element orientations are distinguishable to less than 0.1°, while spatial geometric accuracy is limited by the detector resolution.
- 12 March 2008
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 130 (2)
Probing Microstructure Dynamics With X-Ray Diffraction Microscopy
We describe our recent work on developing X-ray diffraction microscopy as a tool for studying three dimensional microstructure dynamics. This is a measurement technique that is demanding of experimental hardware and presents a challenging computational problem to reconstruct the sample microstructure. A dedicated apparatus exists at beamline 1-ID of the Advanced Photon Source for performing these measurements. Submicron mechanical precision is combined with focusing optics that yield wide line focused beam at . Our forward modeling analysis approach generates diffraction from a simulated two dimensional triangular mesh. Each mesh element is assigned an independent orientation by optimizing the fit to experimental data. The method is computationally demanding but is adaptable to parallel computation. We illustrate the state of development by measuring and reconstructing a planar section of an aluminum polycrystal microstructure. An orientation map of grains is obtained along with a map showing the spatial variation in the quality of the fit to the data. Sensitivity to orientation variations within grains is on the order of . Volumetric studies of the response of microstructures to thermal or mechanical treatment will soon become practical. It should be possible to incorporate explicit treatment of defect distributions and to observe their evolution.- 12 March 2008
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 130 (2)
Probing Microstructure Dynamics With X-Ray Diffraction Microscopy
We describe our recent work on developing X-ray diffraction microscopy as a tool for studying three dimensional microstructure dynamics. This is a measurement technique that is demanding of experimental hardware and presents a challenging computational problem to reconstruct the sample microstructure. A dedicated apparatus exists at beamline 1-ID of the Advanced Photon Source for performing these measurements. Submicron mechanical precision is combined with focusing optics that yield wide line focused beam at . Our forward modeling analysis approach generates diffraction from a simulated two dimensional triangular mesh. Each mesh element is assigned an independent orientation by optimizing the fit to experimental data. The method is computationally demanding but is adaptable to parallel computation. We illustrate the state of development by measuring and reconstructing a planar section of an aluminum polycrystal microstructure. An orientation map of grains is obtained along with a map showing the spatial variation in the quality of the fit to the data. Sensitivity to orientation variations within grains is on the order of . Volumetric studies of the response of microstructures to thermal or mechanical treatment will soon become practical. It should be possible to incorporate explicit treatment of defect distributions and to observe their evolution.