John Walker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John Walker has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Enrique Lopera
Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas
3 shared publications - Marina Borrego
Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas
2 shared publications - Annie Dang
Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas
1 shared publication Carlos B. Ortiz
From the Department of Radiology, University of Texas at San Antonio, 7703 Floyd Curl Dr, San Antonio, TX 78229
1 shared publication- Carlos B. Ortiz
Department of Radiology, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas; Long School of Medicine, The University of Texas Health Sciences Center San Antonio, San Antonio, Texas
1 shared publication - Christopher A. Mao
University of Texas Health Science Center San Antonio, San Antonio, Texas, United States of America
1 shared publication
Latest Publications
- 25 February 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (5) , 108608
Superheating of the Collecting System during Renal Microwave Ablations; Experimental Study Using an Ex Vivo Perfused Kidney Model
- 25 February 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (5) , 108608
Superheating of the Collecting System during Renal Microwave Ablations; Experimental Study Using an Ex Vivo Perfused Kidney Model
- 1 July 2024
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 44 (7) , e230155
Biliary Leaks: Multidisciplinary Approach to Diagnosis and Treatment
Bile leaks arise from various causes such as trauma, complications after hepatobiliary surgery, and intrahepatic malignancies or their associated liver-directed treatments. Bile leaks can result in significant morbidity and mortality. Delayed diagnosis is not uncommon due to nonspecific manifestations; therefore, a high clinical suspicion is needed. A multidisciplinary approach for treatment of biliary leaks with prompt referral to tertiary care centers with experienced hepatobiliary surgeons, advanced endoscopists, and interventional radiologists is needed to address these challenging complications. Management of biliary leaks can range from conservative management to open surgical repair. Minimally invasive procedures play a crucial role in biliary leak treatment, and the interventional radiologist can help guide appropriate management on the basis of a clear understanding of the pathophysiology of biliary leaks and a current knowledge of the armamentarium of treatment options. In most cases, a simple diversion of bile to decompress the biliary system may prove effective. However, persistent and high-output biliary leaks require delineation of the source with tailored treatment options to control the leak. This may be done by additional diversions, occluding the source, reestablishing connections, or using a combination of therapies to bridge to more definitive surgical interventions. The authors describe the different treatment options and emphasize the role of interventional radiology. ©RSNA, 2024.
- 1 July 2024
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 44 (7) , e230155
Biliary Leaks: Multidisciplinary Approach to Diagnosis and Treatment
Bile leaks arise from various causes such as trauma, complications after hepatobiliary surgery, and intrahepatic malignancies or their associated liver-directed treatments. Bile leaks can result in significant morbidity and mortality. Delayed diagnosis is not uncommon due to nonspecific manifestations; therefore, a high clinical suspicion is needed. A multidisciplinary approach for treatment of biliary leaks with prompt referral to tertiary care centers with experienced hepatobiliary surgeons, advanced endoscopists, and interventional radiologists is needed to address these challenging complications. Management of biliary leaks can range from conservative management to open surgical repair. Minimally invasive procedures play a crucial role in biliary leak treatment, and the interventional radiologist can help guide appropriate management on the basis of a clear understanding of the pathophysiology of biliary leaks and a current knowledge of the armamentarium of treatment options. In most cases, a simple diversion of bile to decompress the biliary system may prove effective. However, persistent and high-output biliary leaks require delineation of the source with tailored treatment options to control the leak. This may be done by additional diversions, occluding the source, reestablishing connections, or using a combination of therapies to bridge to more definitive surgical interventions. The authors describe the different treatment options and emphasize the role of interventional radiology. ©RSNA, 2024.
- 18 June 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (10) , 1551-1557.e1
Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model
- 18 June 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (10) , 1551-1557.e1
Changes in Microwave Ablation Zone Dimensions after Transarterial Embolization in an Ex Vivo Human Kidney Perfusion Model
- 31 December 2023
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 54 (1) , 17-33
Anchor Beams with Needles. An East Anglian Mystery
In Essex and Suffolk there are a number of fifteenth- to seventeenth-century timber-framed houses that have the end of an anchor beam protruding from their side walls, which in most cases carry the...
- 31 December 2023
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 54 (1) , 17-33
Anchor Beams with Needles. An East Anglian Mystery
In Essex and Suffolk there are a number of fifteenth- to seventeenth-century timber-framed houses that have the end of an anchor beam protruding from their side walls, which in most cases carry the...
- Open Access
- 13 November 2019
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 478 (1) , 179-188
Can Dynamic Contrast-Enhanced CT Quantify Perfusion in a Stimulated Muscle of Limited Size? A Rat Model
Background: Muscle injury may result in damage to the vasculature, rendering it unable to meet the metabolic demands of muscle regeneration and healing. Therefore, therapies frequently aim to maintain, restore, or improve blood supply to the injured muscle. Although there are several options to assess the vascular outcomes of these therapies, few are capable of spatially assessing perfusion in large volumes of tissue. Questions/purposes: Can dynamic contrast-enhanced CT (DCE-CT) imaging acquired with a clinical CT scanner be used in a rat model to quantify perfusion in the anterior tibialis muscle at spatially relevant volumes, as assessed by (1) the blood flow rate and tissue blood volume in the muscle after three levels of muscle stimulation (low, medium, and maximum) relative to baseline as determined by the non-stimulated contralateral leg; and (2) how do these measurements compare with those obtained by the more standard approach of microsphere perfusion? Methods: The right anterior tibialis muscles of adult male Sprague Dawley rats were randomized to low- (n = 10), medium- (n = 6), or maximum- (n = 3) level (duty cycles of 2.5%, 5.0%, and 20%, respectively) nerve electrode coupled muscle stimulation directly followed by DCE-CT imaging. Tissue blood flow and blood volume maps were created using commercial software and volumetrically measured using NIH software. Although differences in blood flow were detectable across the studied levels of muscle stimulation, a review of the evidence suggested the absolute blood flow quantified was underestimated. Therefore, at a later date, a separate set of adult male Sprague Dawley rats were randomized for microsphere perfusion (n = 7) to define blood flow in the animal model with an accepted standard. With this technique, intra-arterial particles sized to freely flow in blood but large enough to lodge in tissue capillaries were injected. Simultaneously, blood sampling at a fixed flow rate was simultaneously performed to provide a fixed blood flow rate sample. The tissues of interest were then explanted and assessed for the total number of particles per tissue volume. Tissue blood flow rate was then calculated based on the particle count ratio within the reference sample. Note that a tissue’s blood volume cannot be calculated with this method. Comparison analysis to the non-stimulated baseline leg was performed using two-tailed paired student t-test. An ANOVA was used to compare difference between stimulation groups. Results: DCE-CT measured (mean ± SD) increasing tissue blood flow differences in stimulated anterior tibialis muscle at 2.5% duty cycle (32 ± 5 cc/100 cc/min), 5.0% duty cycle (46 ± 13 cc/100 cc/min), and 20% duty cycle (73 ± 3 cc/100 cc/min) compared with the paired contralateral non-stimulated anterior tibialis muscle (10 ± 2 cc/100 cc/min, mean difference 21 cc/100 cc/min [95% CI 17.08 to 25.69]; 9 ± 1 cc/100 cc/min, mean difference 37 cc/100 cc/min [95% CI 23.06 to 50.11]; and 11 ± 2 cc/100 cc/min, mean difference 62 cc/100 cc/min [95% CI 53.67 to 70.03]; all p < 0.001). Similarly, DCE-CT showed increasing differences in tissue blood volumes within the stimulated anterior tibialis muscle at 2.5% duty cycle (23.2 ± 4.2 cc/100 cc), 5.0% duty cycle (39.2 ± 7.2 cc/100 cc), and 20% duty cycle (52.5 ± 13.1 cc/100 cc) compared with the paired contralateral non-stimulated anterior tibialis muscle (3.4 ± 0.7 cc/100 cc, mean difference 19.8 cc/100 cc [95% CI 16.46 to 23.20]; p < 0.001; 3.5 ± 0.4 cc/100 cc, mean difference 35.7 cc/100 cc [95% CI 28.44 to 43.00]; p < 0.001; and 4.2 ± 1.3 cc/100 cc, mean difference 48.3 cc/100 cc [95% CI 17.86 to 78.77]; p = 0.010). Microsphere perfusion measurements also showed an increasing difference in tissue blood flow in the stimulated anterior tibialis muscle at 2.5% duty cycle (62 ± 43 cc/100 cc/min), 5.0% duty cycle (89 ± 52 cc/100 cc/min), and 20% duty cycle (313 ± 269 cc/100 cc/min) compared with the paired contralateral non-stimulated anterior tibialis muscle (8 ± 4 cc/100 cc/min, mean difference 55 cc/100 cc/min [95% CI 15.49 to 94.24]; p = 0.007; 9 ± 9 cc/100 cc/min, mean difference 79 cc/100 cc/min [95% CI 33.83 to 125.09]; p = 0.003; and 18 ± 18 cc/100 cc/min, mean difference 295 cc/100 cc/min [95% CI 8.45 to 580.87]; p = 0.023). Qualitative comparison between the methods suggests that DCE-CT values underestimate tissue blood flow with a post-hoc ANOVA showing DCE-CT blood flow values within the 2.5% duty cycle group (32 ± 5 cc/100 cc/min) to be less than the microsphere perfusion value (62 ± 43 cc/100 cc/min) with a mean difference of 31 cc/100 cc/min (95% CI 2.46 to 60.23; p = 0.035). Conclusions: DCE-CT using a clinical scanner is a feasible modality to measure incremental changes of blood flow and tissue blood volume within a spatially challenged small animal model. Care should be taken in studies where true blood flow values are needed, as this particular small-volume muscle model suggests true blood flow is underestimated using the specific adaptions of DCE-CT acquisition and image processing chosen. Clinical Relevance: CT perfusion is a clinically available modality allowing for translation of science from bench to bedside. Adapting the modality to fit small animal models that are relevant to muscle healing may hasten time to clinical utility.
- 13 November 2019
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 478 (1) , 179-188
Open AccessCan Dynamic Contrast-Enhanced CT Quantify Perfusion in a Stimulated Muscle of Limited Size? A Rat Model
Background: Muscle injury may result in damage to the vasculature, rendering it unable to meet the metabolic demands of muscle regeneration and healing. Therefore, therapies frequently aim to maintain, restore, or improve blood supply to the injured muscle. Although there are several options to assess the vascular outcomes of these therapies, few are capable of spatially assessing perfusion in large volumes of tissue. Questions/purposes: Can dynamic contrast-enhanced CT (DCE-CT) imaging acquired with a clinical CT scanner be used in a rat model to quantify perfusion in the anterior tibialis muscle at spatially relevant volumes, as assessed by (1) the blood flow rate and tissue blood volume in the muscle after three levels of muscle stimulation (low, medium, and maximum) relative to baseline as determined by the non-stimulated contralateral leg; and (2) how do these measurements compare with those obtained by the more standard approach of microsphere perfusion? Methods: The right anterior tibialis muscles of adult male Sprague Dawley rats were randomized to low- (n = 10), medium- (n = 6), or maximum- (n = 3) level (duty cycles of 2.5%, 5.0%, and 20%, respectively) nerve electrode coupled muscle stimulation directly followed by DCE-CT imaging. Tissue blood flow and blood volume maps were created using commercial software and volumetrically measured using NIH software. Although differences in blood flow were detectable across the studied levels of muscle stimulation, a review of the evidence suggested the absolute blood flow quantified was underestimated. Therefore, at a later date, a separate set of adult male Sprague Dawley rats were randomized for microsphere perfusion (n = 7) to define blood flow in the animal model with an accepted standard. With this technique, intra-arterial particles sized to freely flow in blood but large enough to lodge in tissue capillaries were injected. Simultaneously, blood sampling at a fixed flow rate was simultaneously performed to provide a fixed blood flow rate sample. The tissues of interest were then explanted and assessed for the total number of particles per tissue volume. Tissue blood flow rate was then calculated based on the particle count ratio within the reference sample. Note that a tissue’s blood volume cannot be calculated with this method. Comparison analysis to the non-stimulated baseline leg was performed using two-tailed paired student t-test. An ANOVA was used to compare difference between stimulation groups. Results: DCE-CT measured (mean ± SD) increasing tissue blood flow differences in stimulated anterior tibialis muscle at 2.5% duty cycle (32 ± 5 cc/100 cc/min), 5.0% duty cycle (46 ± 13 cc/100 cc/min), and 20% duty cycle (73 ± 3 cc/100 cc/min) compared with the paired contralateral non-stimulated anterior tibialis muscle (10 ± 2 cc/100 cc/min, mean difference 21 cc/100 cc/min [95% CI 17.08 to 25.69]; 9 ± 1 cc/100 cc/min, mean difference 37 cc/100 cc/min [95% CI 23.06 to 50.11]; and 11 ± 2 cc/100 cc/min, mean difference 62 cc/100 cc/min [95% CI 53.67 to 70.03]; all p < 0.001). Similarly, DCE-CT showed increasing differences in tissue blood volumes within the stimulated anterior tibialis muscle at 2.5% duty cycle (23.2 ± 4.2 cc/100 cc), 5.0% duty cycle (39.2 ± 7.2 cc/100 cc), and 20% duty cycle (52.5 ± 13.1 cc/100 cc) compared with the paired contralateral non-stimulated anterior tibialis muscle (3.4 ± 0.7 cc/100 cc, mean difference 19.8 cc/100 cc [95% CI 16.46 to 23.20]; p < 0.001; 3.5 ± 0.4 cc/100 cc, mean difference 35.7 cc/100 cc [95% CI 28.44 to 43.00]; p < 0.001; and 4.2 ± 1.3 cc/100 cc, mean difference 48.3 cc/100 cc [95% CI 17.86 to 78.77]; p = 0.010). Microsphere perfusion measurements also showed an increasing difference in tissue blood flow in the stimulated anterior tibialis muscle at 2.5% duty cycle (62 ± 43 cc/100 cc/min), 5.0% duty cycle (89 ± 52 cc/100 cc/min), and 20% duty cycle (313 ± 269 cc/100 cc/min) compared with the paired contralateral non-stimulated anterior tibialis muscle (8 ± 4 cc/100 cc/min, mean difference 55 cc/100 cc/min [95% CI 15.49 to 94.24]; p = 0.007; 9 ± 9 cc/100 cc/min, mean difference 79 cc/100 cc/min [95% CI 33.83 to 125.09]; p = 0.003; and 18 ± 18 cc/100 cc/min, mean difference 295 cc/100 cc/min [95% CI 8.45 to 580.87]; p = 0.023). Qualitative comparison between the methods suggests that DCE-CT values underestimate tissue blood flow with a post-hoc ANOVA showing DCE-CT blood flow values within the 2.5% duty cycle group (32 ± 5 cc/100 cc/min) to be less than the microsphere perfusion value (62 ± 43 cc/100 cc/min) with a mean difference of 31 cc/100 cc/min (95% CI 2.46 to 60.23; p = 0.035). Conclusions: DCE-CT using a clinical scanner is a feasible modality to measure incremental changes of blood flow and tissue blood volume within a spatially challenged small animal model. Care should be taken in studies where true blood flow values are needed, as this particular small-volume muscle model suggests true blood flow is underestimated using the specific adaptions of DCE-CT acquisition and image processing chosen. Clinical Relevance: CT perfusion is a clinically available modality allowing for translation of science from bench to bedside. Adapting the modality to fit small animal models that are relevant to muscle healing may hasten time to clinical utility.
- 1 January 2019
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 50 (1) , 130-131
Household Inventories of Helmingham Hall, 1597–1741
(2019). Household Inventories of Helmingham Hall, 1597–1741. Vernacular Architecture. Ahead of Print.
- 1 January 2019
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 50 (1) , 130-131
Household Inventories of Helmingham Hall, 1597–1741
(2019). Household Inventories of Helmingham Hall, 1597–1741. Vernacular Architecture. Ahead of Print.
- 1 January 2017
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 48 (1) , 63-77
The Carpentry of a Twelfth-Century Aisled Hall: Burmington Manor, Warwickshire
Burmington Manor is a stone-walled aisled manor house with a timber arcade and timber posts for the central truss of the open hall. It also includes a high end first-floor chamber lit by a twelfth-century stone window. Its date has hitherto been uncertain, but has now been determined as 1194/5d. This was a little later than expected from its primitive carpentry. The main discovery from our further examination is that the central arcade posts are in two parts, the upper sections tenoned into sockets in the top of the capitals. The high end chamber was previously thought to be contained within a crosswing; this is now uncertain and the building may have continued in line with the twelfth-century window in a dormer. The unusual face-splayed scarf joint in the arcade plate has also been closely examined.
- 1 January 2017
- Published by Taylor & Francis in Vernacular Architecture
- Vol. 48 (1) , 63-77
The Carpentry of a Twelfth-Century Aisled Hall: Burmington Manor, Warwickshire
Burmington Manor is a stone-walled aisled manor house with a timber arcade and timber posts for the central truss of the open hall. It also includes a high end first-floor chamber lit by a twelfth-century stone window. Its date has hitherto been uncertain, but has now been determined as 1194/5d. This was a little later than expected from its primitive carpentry. The main discovery from our further examination is that the central arcade posts are in two parts, the upper sections tenoned into sockets in the top of the capitals. The high end chamber was previously thought to be contained within a crosswing; this is now uncertain and the building may have continued in line with the twelfth-century window in a dormer. The unusual face-splayed scarf joint in the arcade plate has also been closely examined.
- 26 March 2013
- Published by Taylor & Francis in Teaching and Learning in Medicine
- Vol. 25 (2) , 118-121
Pharmacist-Led Workshops to Enhance Pharmacotherapy Knowledge for Medical Students
Background: Graduating medical students have reported concern regarding inadequate training in pharmacotherapy. Teaching by clinical pharmacists may improve medical students’ pharmacotherapy knowledge. Purpose: To assess the impact of pharmacist led workshops on 4th year medical students’ knowledge of pharmacotherapy and satisfaction. Methods: Senior medical students enrolled in intensive care unit rotations at a US medical school were randomized to an intervention of pharmacist led case-based workshops or a control group without an explicit pharmacotherapy curriculum. Intervention group students attended four weekly 1-hour workshops that covered topics in pharmacokinetics, pharmacodynamics, drug interactions and toxicity. A multiple-choice test of clinical vignettes assessed students’ knowledge of pharmacotherapy. An end of clerkship survey assessed student satisfaction with teaching. Results: Of 176 medical students eligible, 148 agreed to participate and were randomized to the intervention (n = 63) or control groups (n = 85). Student satisfaction with pharmacist led workshops was high. End of clerkship performance on clinical vignettes (minimum score 0, maximum 100) was similar between the groups (mean score 47 (SD = 12.2) for intervention vs 44 (SD = 13.0) for control group, p = 0.16). On end of clerkship survey, only 8% of control group students agreed or strongly agreed that the standard curriculum provided sufficient teaching in pharmacotherapy. The majority of students (82%) felt that pharmacotherapy should be taught formally in the clinical years. Conclusion: Pharmacist led workshops on pharmacotherapy were well received by senior medical students but did not improve performance on a test of pharmacotherapy knowledge. Further study is needed to define optimal strategies for improving medical students’ pharmacotherapy knowledge.
- 26 March 2013
- Published by Taylor & Francis in Teaching and Learning in Medicine
- Vol. 25 (2) , 118-121
Pharmacist-Led Workshops to Enhance Pharmacotherapy Knowledge for Medical Students
Background: Graduating medical students have reported concern regarding inadequate training in pharmacotherapy. Teaching by clinical pharmacists may improve medical students’ pharmacotherapy knowledge. Purpose: To assess the impact of pharmacist led workshops on 4th year medical students’ knowledge of pharmacotherapy and satisfaction. Methods: Senior medical students enrolled in intensive care unit rotations at a US medical school were randomized to an intervention of pharmacist led case-based workshops or a control group without an explicit pharmacotherapy curriculum. Intervention group students attended four weekly 1-hour workshops that covered topics in pharmacokinetics, pharmacodynamics, drug interactions and toxicity. A multiple-choice test of clinical vignettes assessed students’ knowledge of pharmacotherapy. An end of clerkship survey assessed student satisfaction with teaching. Results: Of 176 medical students eligible, 148 agreed to participate and were randomized to the intervention (n = 63) or control groups (n = 85). Student satisfaction with pharmacist led workshops was high. End of clerkship performance on clinical vignettes (minimum score 0, maximum 100) was similar between the groups (mean score 47 (SD = 12.2) for intervention vs 44 (SD = 13.0) for control group, p = 0.16). On end of clerkship survey, only 8% of control group students agreed or strongly agreed that the standard curriculum provided sufficient teaching in pharmacotherapy. The majority of students (82%) felt that pharmacotherapy should be taught formally in the clinical years. Conclusion: Pharmacist led workshops on pharmacotherapy were well received by senior medical students but did not improve performance on a test of pharmacotherapy knowledge. Further study is needed to define optimal strategies for improving medical students’ pharmacotherapy knowledge.
- 1 June 1996
- Published by Elsevier in Journal of Chromatography A
- Vol. 737 (2) , 273-279
Purification of hydrophobic integral membrane proteins from Mycoplasma hyopneumoniae by reversed-phase high-performance liquid chromatography
- 1 June 1996
- Published by Elsevier in Journal of Chromatography A
- Vol. 737 (2) , 273-279
Purification of hydrophobic integral membrane proteins from Mycoplasma hyopneumoniae by reversed-phase high-performance liquid chromatography