Xianghua Ying
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xianghua Ying has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Zhanyi Hu
Inst. of Autom., Chinese Acad. of Sci., Beijing, China
1 shared publication
Latest Publications
- 16 August 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 26 (10) , 1260-1271
Catadioptric camera calibration using geometric invariants
Central catadioptric cameras are imaging devices that use mirrors to enhance the field of view while preserving a single effective viewpoint. In this paper, we propose a novel method for the calibration of central catadioptric cameras using geometric invariants. Lines and spheres in space are all projected into conics in the catadioptric image plane. We prove that the projection of a line can provide three invariants whereas the projection of a sphere can only provide two. From these invariants, constraint equations for the intrinsic parameters of catadioptric camera are derived. Therefore, there are two kinds of variants of this novel method. The first one uses projections of lines and the second one uses projections of spheres. In general, the projections of two lines or three spheres are sufficient to achieve catadioptric camera calibration. One important conclusion in this paper is that the method based on projections of spheres is more robust and has higher accuracy than that based on projections of lines. The performances of our method are demonstrated by both the results of simulations and experiments with real images.
- 16 August 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Pattern Analysis and Machine Intelligence
- Vol. 26 (10) , 1260-1271
Catadioptric camera calibration using geometric invariants
Central catadioptric cameras are imaging devices that use mirrors to enhance the field of view while preserving a single effective viewpoint. In this paper, we propose a novel method for the calibration of central catadioptric cameras using geometric invariants. Lines and spheres in space are all projected into conics in the catadioptric image plane. We prove that the projection of a line can provide three invariants whereas the projection of a sphere can only provide two. From these invariants, constraint equations for the intrinsic parameters of catadioptric camera are derived. Therefore, there are two kinds of variants of this novel method. The first one uses projections of lines and the second one uses projections of spheres. In general, the projections of two lines or three spheres are sufficient to achieve catadioptric camera calibration. One important conclusion in this paper is that the method based on projections of spheres is more robust and has higher accuracy than that based on projections of lines. The performances of our method are demonstrated by both the results of simulations and experiments with real images.