Hui Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Duan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hongli Liu
Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China
1 shared publication - Jiawei Wang
Economic and Technological Research Institute of State Grid Shanxi Electric Power Co., Ltd., Taiyuan 030000, China
1 shared publication - Juan Yu
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
1 shared publication - Qingyue Ran
State Grid Chongqing Electric Power Research Institute, Chongqing 404100, China
1 shared publication - Yao Wang
Economic and Technological Research Institute, State Grid Shanxi Electric Power Company Limited, Taiyuan 030024, China
1 shared publication - Zhi Zhang
Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030021, China
1 shared publication
Latest Publications
- Open Access
A Feasible Region-Based Evaluation Method for the Renewable Energy Hosting Capacity with Frequency Security Constraints
As renewable energy becomes more widespread, the uncertainty of its output poses serious challenges for peak and frequency regulation of the power system. Evaluating a grid’s capacity to integrate renewable energy sources can provide an early-warning and decision-making basis for grid operation and scheduling. This paper presents a method for evaluating the hosting capacity of renewable energy, considering frequency security constraints. Introducing the system frequency nadir constraint into a system ensures that the frequency does not drop to a dangerous level in the event of power disturbances. The analytical characterization relation equation for the system frequency nadir constraint is constructed based on polynomial chaos expansion (PCE) theory. Furthermore, with the goal of minimizing the reduction in renewable energy, considering multiple flexible resources, like demand response (DR), Combined Heat and Power (CHP), energy storage, and Power-to-Gas (P2G), a renewable energy hosting capacity evaluation model that considers frequency security and flexibility resources is established. Finally, based on the concept of the feasible region, the maximum hosting capacity of a system’s renewable energy is visualized using the progressive vertex enumeration method. It identifies the safe operating region for renewable energy output that meets the safety constraints of power grid operations. The simulation results were validated using a modified IEEE 39 bus system.
Open AccessA Feasible Region-Based Evaluation Method for the Renewable Energy Hosting Capacity with Frequency Security Constraints
As renewable energy becomes more widespread, the uncertainty of its output poses serious challenges for peak and frequency regulation of the power system. Evaluating a grid’s capacity to integrate renewable energy sources can provide an early-warning and decision-making basis for grid operation and scheduling. This paper presents a method for evaluating the hosting capacity of renewable energy, considering frequency security constraints. Introducing the system frequency nadir constraint into a system ensures that the frequency does not drop to a dangerous level in the event of power disturbances. The analytical characterization relation equation for the system frequency nadir constraint is constructed based on polynomial chaos expansion (PCE) theory. Furthermore, with the goal of minimizing the reduction in renewable energy, considering multiple flexible resources, like demand response (DR), Combined Heat and Power (CHP), energy storage, and Power-to-Gas (P2G), a renewable energy hosting capacity evaluation model that considers frequency security and flexibility resources is established. Finally, based on the concept of the feasible region, the maximum hosting capacity of a system’s renewable energy is visualized using the progressive vertex enumeration method. It identifies the safe operating region for renewable energy output that meets the safety constraints of power grid operations. The simulation results were validated using a modified IEEE 39 bus system.