Manisha Rauniyar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Manisha Rauniyar has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Hossein Moradi Rekabdarkolaee
Department of Mathematics and Statistics, South Dakota State University, Brookings, SD, USA
1 shared publicationMariko Shirazi
Alaska Center for Energy and Power, University of Alaska Fairbanks, Fairbanks, AK, USA
1 shared publication- Niranjan Bhujel
Sandia National Laboratories, Albuquerque, NM, USA
1 shared publication - Phylicia Cicilio
Alaska Center for Energy and Power, University of Alaska, Fairbanks, AK 99775, USA
1 shared publication - Reinaldo Tonkoski
Technical University of Munich
1 shared publication Robert Fourney
Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD, USA
1 shared publication
Latest Publications
- Open Access
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 86319-86332
Experimental Validation of a Diesel Genset Frequency Dynamics Model for Use in Remote Area Power Systems
Diesel generators (gensets) are often the lowest-cost electric generation for reliable supply in remote microgrids. The development of converter-dominated diesel-backed microgrids requires accurate dynamic modeling to ensure power quality and system stability. Dynamic response derived using original genset system models often does not match those observed in field experiments. This paper presents the experimental system identification of a frequency dynamics model for a 400 kVA diesel genset. The genset is perturbed via active power load changes and a linearized dynamics model is fit based on power and frequency measurements using moving horizon estimation (MHE). The method is first simulated using a detailed genset model developed in MATLAB/Simulink. The simulation model is then validated against the frequency response obtained from a real 400 kVA genset system at the Power System Integration (PSI) Lab at the University of Alaska Fairbanks (UAF). The simulation and experimental results had model errors of 3.17% and 11.65%, respectively. The resulting genset model can then be used in microgrid frequency dynamic studies, such as for the integration of renewable energy sources.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 86319-86332
Open AccessExperimental Validation of a Diesel Genset Frequency Dynamics Model for Use in Remote Area Power Systems
Diesel generators (gensets) are often the lowest-cost electric generation for reliable supply in remote microgrids. The development of converter-dominated diesel-backed microgrids requires accurate dynamic modeling to ensure power quality and system stability. Dynamic response derived using original genset system models often does not match those observed in field experiments. This paper presents the experimental system identification of a frequency dynamics model for a 400 kVA diesel genset. The genset is perturbed via active power load changes and a linearized dynamics model is fit based on power and frequency measurements using moving horizon estimation (MHE). The method is first simulated using a detailed genset model developed in MATLAB/Simulink. The simulation model is then validated against the frequency response obtained from a real 400 kVA genset system at the Power System Integration (PSI) Lab at the University of Alaska Fairbanks (UAF). The simulation and experimental results had model errors of 3.17% and 11.65%, respectively. The resulting genset model can then be used in microgrid frequency dynamic studies, such as for the integration of renewable energy sources.