Lauren May
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lauren May has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Anatoly Rosenfeld
Centre for Medical and Radiation Physics, University of Wollongong, NSW, Australia
3 shared publicationsJoel Poder
Centre for Medical and Radiation Physics, University of Wollongong, NSW, Australia; St George Cancer Care Centre, St George Hospital, Kogarah, NSW, Australia; School of Physics, University of Sydney, Camperdown, NSW, Australia
3 shared publications- Jordi Saez
Department of Radiation Oncology Hospital Clínic de Barcelona Barcelona Spain
2 shared publications Mohammad Hussein
Department of Radiation Oncology King Khalid University Medical City Abha Saudi Arabia
2 shared publications- Nicholas Hardcastle
Peter MacCallum Cancer Centre
2 shared publications Peter B. Greer
Department of Radiation Oncology Calvary Mater Hospital Newcastle New South Wales Australia
2 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Linac performance benchmarking: Feasibility of a web‐based tool for comparison of local machine performance check (MPC) results with the global community
Background: Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests. MPC is a highly standardized method of performance testing, is generally free of inter‐user variability and is quick and easy to perform allowing daily acquisitions. Therefore, previous studies have highlighted the potential of comparative analysis of MPC data in investigating differences in performance of individual linacs and identifying outliers. Statistical process control (SPC) is an established approach commonly used to assess stability and behavior of sequential data and identify standard operating ranges which has previously been applied to radiotherapy quality assurance data and MPC data. Purpose: This study aimed to investigate the feasibility of a web‐based platform using SPC and aggregated MPC data to allow users to compare their machine performance against that of a cohort of others in the radiotherapy community. Methods: A previously developed web‐based platform for radiotherapy data sharing was expanded to include the MPC data collection and comparison tool. Pilot centers exported data from their MPC applications and uploaded it through center‐specific portals. Within the application, SPC analysis was used to calculate upper control limits (UCL), lower control limits (LCL) and central lines (CL) for the data sets of each individual linac as well as cohort averages. Interactive plots of longitudinal data for individual machines were displayed for users and overlaid with SPC limits for the specific machine and the cohort averages. Additional analyses were conducted externally from the app where the average and range of SPC control limits for the cohort were compared against MPC tolerances. Results: MPC data for 57 648 measurements taken between April 2016 and May 2026 were collected across seven centers from 21 TrueBeam linacs (15 with Millennium multi‐leaf collimator (MLC), six with HD120 MLCs) and one Halcyon. Variation in performance for specific tests was identified for individual machines compared against the cohort as well as for individual MLC leaves for specific machines. Across the cohort of TrueBeam linacs, average control ranges for all geometric tests were within MPC thresholds. However, the range of values for UCL and LCL exceeded tolerances for relative gantry angle. Machines installed before 2021 were found to have slightly larger variability in mean MLC offset with an average control range width of 0.20 mm and 0.18 mm for bank A and B, respectively, compared to machines installed after 2021 of 0.10 mm and 0.13 mm. Analysis of data for individual linacs segmented per year showed a change in mean MLC offset occurring around 2021. Conclusions: The usefulness and feasibility of a tool to compare MPC data against the radiotherapy community was demonstrated. Inter‐center comparison of data allowed trends to be identified which would otherwise not be observable for individual centers. Further development and distribution of the MPC data sharing and comparison tool may provide improved confidence and understanding of machine performance and assist low‐resourced clinics in delivering safe and accurate radiotherapy treatments.
- 28 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessLinac performance benchmarking: Feasibility of a web‐based tool for comparison of local machine performance check (MPC) results with the global community
Background: Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests. MPC is a highly standardized method of performance testing, is generally free of inter‐user variability and is quick and easy to perform allowing daily acquisitions. Therefore, previous studies have highlighted the potential of comparative analysis of MPC data in investigating differences in performance of individual linacs and identifying outliers. Statistical process control (SPC) is an established approach commonly used to assess stability and behavior of sequential data and identify standard operating ranges which has previously been applied to radiotherapy quality assurance data and MPC data. Purpose: This study aimed to investigate the feasibility of a web‐based platform using SPC and aggregated MPC data to allow users to compare their machine performance against that of a cohort of others in the radiotherapy community. Methods: A previously developed web‐based platform for radiotherapy data sharing was expanded to include the MPC data collection and comparison tool. Pilot centers exported data from their MPC applications and uploaded it through center‐specific portals. Within the application, SPC analysis was used to calculate upper control limits (UCL), lower control limits (LCL) and central lines (CL) for the data sets of each individual linac as well as cohort averages. Interactive plots of longitudinal data for individual machines were displayed for users and overlaid with SPC limits for the specific machine and the cohort averages. Additional analyses were conducted externally from the app where the average and range of SPC control limits for the cohort were compared against MPC tolerances. Results: MPC data for 57 648 measurements taken between April 2016 and May 2026 were collected across seven centers from 21 TrueBeam linacs (15 with Millennium multi‐leaf collimator (MLC), six with HD120 MLCs) and one Halcyon. Variation in performance for specific tests was identified for individual machines compared against the cohort as well as for individual MLC leaves for specific machines. Across the cohort of TrueBeam linacs, average control ranges for all geometric tests were within MPC thresholds. However, the range of values for UCL and LCL exceeded tolerances for relative gantry angle. Machines installed before 2021 were found to have slightly larger variability in mean MLC offset with an average control range width of 0.20 mm and 0.18 mm for bank A and B, respectively, compared to machines installed after 2021 of 0.10 mm and 0.13 mm. Analysis of data for individual linacs segmented per year showed a change in mean MLC offset occurring around 2021. Conclusions: The usefulness and feasibility of a tool to compare MPC data against the radiotherapy community was demonstrated. Inter‐center comparison of data allowed trends to be identified which would otherwise not be observable for individual centers. Further development and distribution of the MPC data sharing and comparison tool may provide improved confidence and understanding of machine performance and assist low‐resourced clinics in delivering safe and accurate radiotherapy treatments.
- Open Access
- 21 March 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111493
It’s not your device, it’s how you use it – Sensitivity and specificity of PSQA devices in the SEAFARER head and neck study
- 21 March 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 219, 111493
Open AccessIt’s not your device, it’s how you use it – Sensitivity and specificity of PSQA devices in the SEAFARER head and neck study
- Open Access
- 23 January 2025
- Published by Elsevier in Physica Medica
- Vol. 130, 104900
Intrafraction motion in intra-cranial multi-target stereotactic radiosurgery plans: A multi-institutional investigation on robustness
- 23 January 2025
- Published by Elsevier in Physica Medica
- Vol. 130, 104900
Open AccessIntrafraction motion in intra-cranial multi-target stereotactic radiosurgery plans: A multi-institutional investigation on robustness
- Open Access
- 5 July 2024
- Published by Elsevier in Physica Medica
- Vol. 124, 103423
Multi-institutional investigation into the robustness of intra-cranial multi-target stereotactic radiosurgery plans to patient setup errors
- 5 July 2024
- Published by Elsevier in Physica Medica
- Vol. 124, 103423
Open AccessMulti-institutional investigation into the robustness of intra-cranial multi-target stereotactic radiosurgery plans to patient setup errors
- Open Access
- 17 June 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (9) , e13665
Detection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
Purpose: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing.Methods: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations.Results: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors.Conclusions: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs.
- 17 June 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (9) , e13665
Open AccessDetection of rotational errors in single‐isocenter multiple‐target radiosurgery: Is a routine off‐axis Winston–Lutz test necessary?
Purpose: Recently the use of linear accelerator (linac)‐based stereotactic radiosurgery (SRS) has increased, including single‐isocenter multiple‐target SRS. The workload of medical physicists has grown as a result and so has the necessity of maximizing the efficiency of quality assurance (QA). This study aimed to determine if measurement‐based patient‐specific QA with a high‐spatial‐resolution dosimeter is sensitive to rotational errors, potentially reducing the need for routine off‐axis Winston–Lutz (WL) testing.Methods: The impact of rotational errors along gantry, couch, and collimator axes on dose coverage of the gross tumor volume (GTV) and planning target volume (PTV) was determined with a 1‐mm GTV/PTV expansion margin. Two techniques, the off‐axis WL test using the StereoPHAN MultiMet‐WL Cube (Sun Nuclear Corporation, Melbourne, Florida, USA) and patient‐specific QA using the SRS MapCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA), were assessed on their ability to detect introduced errors before target coverage was compromised. These findings were also considered in the context of routine machine QA of rotational axis calibrations.Results: Rotational errors significantly impacted PTV dose coverage, especially in the couch angle. GTV dose coverage remained unaffected except for with large couch angle errors (≥1.5°). The off‐axis WL test was shown to be sensitive to rotational errors with results consistently exceeding tolerance levels when or before coverage fell below departmentally accepted limits. Although patient‐specific QA using the SRS MapCHECK was previously validated for SRS, this study showed inconsistency in detection of rotational errors.Conclusions: It is recommended that off‐axis WL testing be conducted regularly to supplement routine monthly machine QA, as it is sensitive to errors that patient‐specific QA may not detect. This frequency should be determined by individual departments, with consideration of GTV–PTV margins used, limitations on target off‐axis distances, and routine mechanical QA results for particular linacs.