VKVasily V. Korshunov

Vasily V. Korshunov

*This is an algorithmically generated author record based on publicly available information.

Vasily V. Korshunov has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Controlled local hypothermia in the complex treatment of patients with congenital anomalies of jaw development

    by В.в. Коршунов, Ян Лэй, И.в. Черкесов, В.м. Гринин, С.ю. Иванов, А.а. Мураев, А.о. Микия

    На сегодняшний день операции на костях лицевого скелета связаны с такими послеоперационными явлениями, как отек, боль, тризм жевательных мышц и нарушение чувствительности в зоне 2-й и 3-й ветви тройничного нерва. Во многих научных работах было отмечено благоприятное воздействие холодовых компрессов на послеоперационную зону, а анатомо-топографическая особенность челюстной лицевой зоны затрудняет оценку отека лица. Один из перспективных методов реабилитации пациентов — контролируемая локальная гипотермия аппаратным методом, а структурное измерение отека лица — оптическое сканирование. Это исследование было направлено на оценку трехмерного оптического сканера и аппарата ViTermo после ортогнатических операций. Послеоперационный отек лечили либо обычными холодовыми компрессами, либо индивидуально изготовленными лицевыми масками и циркуляционной системой ViTermo. В каждой контрольной группе отмечали боль, жалобы, отек, тризм жевательных мышц, нарушение чувствительности в зоне 2-й и 3-й ветви тройничного нерва, продолжительность пребывания в стационаре и удовлетворенность пациента. Использование охлаждающего устройства ViTermo значительно уменьшило послеоперационный отек и улучшило реабилитацию пациента. Today, operations on the bones of the facial skeleton are associated with such postoperative phenomena as: swelling, pain, trismus of the masticatory muscles and impaired sensitivity in the zone of the 2nd and 3rd branches of the trigeminal nerve. Many scientific works have noted the beneficial effects of cold compresses on the postoperative area, and the anatomical and topographical feature of the maxillary facial area makes it difficult to assess facial edema. One of the promising methods of patient rehabilitation is controlled local hypothermia using a hardware method, and the structural measurement of facial edema is optical scanning. This study aimed to evaluate the 3D optical scanner and the Vitermo device after orthognathic surgery. Postoperative swelling was treated with either conventional cold packs or custom-made face masks and a ViTermo circulation system. In each control group, pain, complaints, swelling, trismus of masticatory muscles, sensory disturbance in the 2nd and 3rd branches of the trigeminal nerve, length of hospital stay, and patient satisfaction were noted. The use of the Vitermo cooling device significantly reduced postoperative swelling and improved patient recovery.


  • The Osteoinductive Potential of Partially Demineralized Bone Matrix and the Possibility of Its Use in Clinical Practice

    by Alexander S. Pankratov, Irina S. Fadeeva, Yulia B. Yurasova, Vasily M. Grinin, Igor V. Cherkesov, Vasily V. Korshunov, Юрасова Юлия Борисовна

    Today autografts are considered to be an optimal material for bone grafting. However, the collection of material and its clinical use is associated with several serious drawbacks, and therefore, in reconstructive surgery, a search for alternative treatment approaches is being conducted. A bone transplant from another person (allo-osteoplasty) is the most natural and logical option for replacing an autobone. Since 1965, allogeneic implants of a partially demineralized bone matrix combining osteoinductive and osteoconductive action have been used in clinical practice. However, the clinical results of the use of this material turned out to be ambiguous, which is due, first of all, to the significant variability of the osteoplastic potential of its various samples. For this reason, in clinical practice, sometimes preference is given to samples of non-demineralized allobone, which retain its structure longer. In this paper, we consider factors affecting the osteoinductive activity of a partially demineralized bone matrix, related both to the technological issues of its preparation and to the clinical conditions of use. Issues of the possible improvement of this material were discussed with a view to its further use in medical practice.