HCHanbing Chu

Hanbing Chu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hanbing Chu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Liyuan Jiang

    Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Xian Jiaotong University, Xian, China

    5 shared publications
  • Meiling Liang

    Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Xian Jiaotong University, Xian, China

    5 shared publications
  • Mingxi Wan

    The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China

    5 shared publications
  • Xiao Su

    Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Xian Jiaotong University, Xian, China

    4 shared publications
  • Yichen Yan

    Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Xian Jiaotong University, Xian, China

    4 shared publications
  • Yujin Zong

    Department of Biomedical Engineering, School of Life Science and Technology, Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xian Jiaotong University, Xian, China

    4 shared publications

Latest Publications

  • Block-Wise Mixed-Order Continuity Constraints for Displacement Estimation in Transcranial Ultrasound Shear Wave Elastography

    by Yiran Chen, Chaoyang Zhang, Hanbing Chu, Yichen Yan, Xiao Su, Yueyuan Wang, Liyuan Jiang, Meiling Liang, Hongmei Zhang, Mingxi Wan

    Transcranial ultrasound shear wave elastography (TSWE) enables noninvasive assessment of brain tissue mechanical properties for diagnosing brain diseases. Accurate Shear Wave displacement estimation is critical for reliable evaluation of tissue mechanics. However, the thickness and heterogeneous structure of the skull induce strong attenuation and scattering of both ultrasound and shear waves. These effects degrade ultrasound tracking quality, weaken Shear Wave propagation in the brain, and introduce substantial noise, thereby reducing the accuracy of Shear Wave displacement estimation. To address this challenge, a block-wise mixed-order continuity constraints (BW-MOUL) method is proposed. This method incorporates first- and second-order regularization to enhance displacement accuracy by improving spatial smoothness and noise suppression, while employing a block-wise matrix strategy to improve computational efficiency. In numerical simulations, cranial phantom experiments, and in vivo goat brain experiments, BW-MOUL demonstrated superior displacement estimation performance, thereby enhancing the accuracy of Shear Wave speed (SWS) estimation and the reliability of viscoelasticity and fluidity assessment. In simulations, BW-MOUL achieved a normalized root-mean-square error (NRMSE) of 4.03% in displacement estimation relative to the ground truth. In phantom experiments, BW-MOUL improved the particle displacement signal-to-noise ratio (PDSNR) by 5.11 and 3.27 dB, and increased the SWS SNR ${}_{t}$ of the tumor region by 10.79 and 4.61, compared to normalized cross correlation (NCC) and global ultrasound elastography (GLUE), respectively. In goat brain experiments, BW-MOUL yielded elasticity, viscosity, and fluidity values of 1452 Pa, 7.077 Pa $\cdot $ s ${}^{\alpha }$ , and 0.9291, respectively, which are consistent with reported goat brain tissue properties. Moreover, the block-wise processing strategy achieved approximately a 66-fold speedup over the global method. Overall, the BW-MOUL method demonstrates strong potential in TSWE for noninvasive diagnosis of brain diseases.


  • High Spatiotemporal Resolution Microvessel Imaging Based on Microbubble Gradient Convergence and Accumulation Reconstruction

    by Hanbing Chu, Liyuan Jiang, Xiao Su, Yichen Yan, Jiacheng Liu, Jinxuan Ma, Meiling Liang, Yiran Chen, Yujin Zong, Mingxi Wan

    the application of medical ultrasound imaging instruments, microvessel detection is the basis for accurate measurement of vessel parameters and hemodynamic parameters, which directly affects the instrument's ability to diagnose diseases early and evaluate treatment effects. Ultrasound localization microscopy enables superresolution imaging and detecting of deep microvessels via microbubble (MB) localization and tracking, but with low temporal resolution. To balance spatial and temporal resolution, higher-order statistics improves spatial resolution and enables the reconstruction of a microvessel image with shorter acquisitions. However, in plane wave imaging, the point spread function (PSF) broadens and changes with depth, limiting spatial resolution gains. To overcome this and further improve spatiotemporal resolution, a nonlocalized dynamic microvessel imaging method called MB gradient convergence and accumulation reconstruction (GCAR) was proposed. The GCAR method is implemented via spatial and temporal transformations of data at high MB concentrations; the spatial transformation anisotropically shrinks and separates MBs toward the center by using the symmetry of the MB gradient, and the temporal transformation reconstructs microvessels by measuring the statistical independence of the MB signals through high-order cross accumulation. The simulation results revealed that GCAR decreased the full width at half maximum of the MBs by 80%, and was able to separate parallel vessels with spacings of 0.25λ (4 MHz) and 0.125λ (10 MHz). The in vivo results revealed that GCAR could quickly reconstruct the microvasculature with a spatial resolution of 18.19 μm (12 MHz) for the rat brain and 76.28 μm (4 MHz) for the rabbit kidney. GCAR dynamically displays blood flow with a temporal resolution of 50 ms. The GCAR approach improves the spatiotemporal resolution of medical ultrasound imaging instruments, detects smaller and more microvessels with shorter acquisition times, which may provide a useful tool for hemodynamic measurement and examination of microvascular diseases.


  • Transcranial Ultrasound Super-Resolution Imaging Using Chirp-Coded Excitation With Adaptive Attenuation Mismatched Filter and Multilayer Correlation Phase Correction

    by Jiacheng Liu, Meiling Liang, Jinxuan Ma, Hanbing Chu, Liyuan Jiang, Yichen Yan, Hao Wang, Xiao Su, Chaoyang Zhang, Yujin Zong, et al.

    Cerebral microvasculature imaging is crucial in the diagnosis of various cerebrovascular diseases. Ultrasound localization microscopy (ULM) enables microvascular imaging at microscopic resolution through the localization of injected microbubbles. However, the strong attenuation of transcranial ultrasound limits the sensitivity of vascular detection, and phase aberration caused by mismatched speed of sound in different tissues reduces the resolution of transcranial ULM (TULM). In this study, a chirp-coded excitation signal was transmitted, and an adaptive attenuation mismatched filter (AMF) was constructed based on the attenuation of each frequency component to improve the signal-to-noise ratio (SNR) and resolution of the compressed signal. Moreover, a multilayer correlation phase correction method was proposed for precision TULM, independently correcting phase aberration in different fields of view. The simulation results confirm that the chirp-coded excitation and AMF increase the SNR by 11.31 dB and the axial resolution by 0.08λ compared with those of the single-pulse excitation under strong attenuation conditions. For phase aberration, the multilayer correlation phase correction improves the lateral and axial resolutions to 0.77λ and 0.19λ, respectively. Additionally, the advanced phase correction method enhances the refocusing ability, improving the contrast by 2.46 dB. For in vivo TULM, the proposed method was more robust, that can reconstruct richer microvascular structures than the conventional method, with a 15.68% increase in saturation. Moreover, the resolution of the microvasculature improved by 7.19 μm (27.24%). These results validate the advantages of the proposed method in achieving rich microvascular reconstruction with higher resolution than conventional methods under transcranial imaging conditions. Thus, the proposed method has application potential in ultrasound imaging of small vessels in the brain.


  • High-resolution hemodynamic estimation from ultrafast ultrasound image velocimetry using a physics-informed neural network

    by Meiling Liang, Jiacheng Liu, Hao Wang, Hanbing Chu, Mingting Zhu, Liyuan Jiang, Yujin Zong, Mingxi Wan

    Objective. Estimating the high-resolution (HR) blood flow velocity and pressure fields for the diagnosis and treatment of vascular diseases remains challenging. Approach. In this study, a physics-informed neural network (PINN) with a refined mapping capability was combined with ultrafast ultrasound image velocimetry (u-UIV) to predict HR hemodynamic parameters. Specifically, the Navier–Stokes equations were encoded into the PINN to dynamically optimize the network performance under physical constraints, and a refined mapping network was added at the input to achieve data refinement. During the prediction of HR ultrasound hemodynamic parameters, only the sparse spatial coordinates in the time series were input into the PINN, and the velocity vectors generated from the u-UIV were used together with physical residuals to enhance the physical correctness of HR predictions during the iterative process. Main results. The performance of the refined mapping network was validated via simulations, with a 1.9-fold increase in the radial resolution and a 2.5-fold increase in the axial resolution. HR velocity field estimation from in vitro and in vivo data showed good agreement with theoretical values and u-UIV measurements, with micrometer-level spatial resolution (88 µm × 115 µm for straight vessel, 75 µm × 120 µm for stenotic vessel and 63 µm × 79 µm for in vivo data), while the pressure field could be inferred from physical laws. Significance. The proposed method performs well when few data samples are available and has the potential to assist in the clinical diagnosis of vascular diseases.


  • High Spatiotemporal Resolution Contrast-Free Ultrasound Microvascular Imaging Using Adaptive Weight-Based Nonlinear Compounding

    by Liyuan Jiang, Hanbing Chu, Yang Liu, Jiacheng Liu, Xiao Su, Yichen Yan, Meiling Liang, Yiran Chen, Chaoyang Zhang, Feiqian Wang, et al.

    Simultaneously improving the spatial and temporal resolution of ultrafast power Doppler imaging (UPDI) is conducive to monitoring rapid changes in microvascular morphology and dynamics and increasing quantification accuracy. Grouped angle singular value decomposition (GA-SVD) has been studied to suppress clutter at enhanced temporal resolution, but it struggles to remove spatially varying noise. This study presents an adaptive weight-based nonlinear compounding method called generalized frame-multiply-and-sum (FMAS) factor based on pth root compression (p-GFMAS) to address the above legacy noise and improve the spatial resolution of UPDI at better temporal resolution. p-GFMAS utilizes angular coherence extracted based on the autocorrelation function to emphasize coherent blood signals and suppress incoherent noise, where the adaptive effect is adjusted by p-value. The effectiveness of the p-GFMAS in improving spatial resolution was verified through simulations. And the superiority of the p-GFMAS united with GA-SVD in enhancing spatiotemporal resolution was validated with in vivo studies. Simulation results demonstrated that p-GFMAS outperforms other compounding methods, and p-GFMAS increased the signal-to-noise ratio (SNR) by 22.77 dB (234%) and reduced the full-width at half-maximum (FWHM) by $274~\mu $ m (43.4%) over traditional coherent compounding (CC). Rat brain and human liver results depicted that p-GFMAS united with GA-SVD achieved highest image quality when using shorter ensembles due to the increased SNR and reduced FWHM. Dynamic results further revealed the ability of the united method to capture flow-dynamics of the rat brain at a frame rate of 20 Hz. Overall, p-GFMAS united with GA-SVD realizes high spatiotemporal resolution contrast-free microvascular visualization, facilitating an understanding of the mechanisms of various physiological and pathological processes.


  • Low-rank prior-based Fast-RPCA for clutter filtering and noise suppression in non-contrast ultrasound microvascular imaging

    by Xiao Su, Yueyuan Wang, Hanbing Chu, Liyuan Jiang, Yadi Yan, Xiaoyang Qiao, Jianjun Yu, Kaitai Guo, Yujin Zong, Mingxi Wan