MSMarvin Stiefermann

Marvin Stiefermann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marvin Stiefermann has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • André Schirmeisen

    Justus-Liebig-Universität Giessen

    1 shared publication
  • Gernot Langewisch

    Center for Nanotechnology (CeNTech) and Institute of Physics, University of Münster (WWU), Heisenbergstrasse 1, 48149 Münster, Germany

    1 shared publication
  • Harald Fuchs

    Center for Nanotechnology (CeNTech) and Institute of Physics, University of Münster (WWU), Heisenbergstrasse 1, 48149 Münster, Germany

    1 shared publication
  • Hendrik Hölscher

    Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz Platz 1, 76344 Eggenstein-Leopoldshafen, Germany

    1 shared publication
  • Jens Falter

    Center for Nanotechnology (CeNTech) and Institute of Physics, University of Münster (WWU), Heisenbergstrasse 1, 48149 Münster, Germany

    1 shared publication
  • Philipp Schurig

    Institute of Applied Physics (IAP), Justus-Liebig-University Gießen, Germany

    1 shared publication

Latest Publications

  • Open Access

    Calibration of quartz tuning fork spring constants for non-contact atomic force microscopy: direct mechanical measurements and simulations

    by Jens Falter, Marvin Stiefermann, Gernot Langewisch, Philipp Schurig, Hendrik Hölscher, Harald Fuchs, André Schirmeisen

    Quartz tuning forks are being increasingly employed as sensors in non-contact atomic force microscopy especially in the “qPlus” design. In this study a new and easily applicable setup has been used to determine the static spring constant at several positions along the prong of the tuning fork. The results show a significant deviation from values calculated with the beam formula. In order to understand this discrepancy the complete sensor set-up has been digitally rebuilt and analyzed by using finite element method simulations. These simulations provide a detailed view of the strain/stress distribution inside the tuning fork. The simulations show quantitative agreement with the beam formula if the beam origin is shifted to the position of zero stress onset inside the tuning fork base and torsional effects are also included. We further found significant discrepancies between experimental calibration values and predictions from the shifted beam formula, which are related to a large variance in tip misalignment during the tuning fork assembling process.