Asahi Yano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Asahi Yano has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- George Hudson-Chang
Department of Physics, University of Surrey, Guildford GU2 7XH, UK
5 shared publications - Takayuki Yamaguchi
Department of Physics, Saitama University, Saitama 338-8570, Japan
5 shared publications - Tetsuaki Moriguchi
Institute of Physics, University of Tsukuba, Ibaraki 305-8571, Japan
4 shared publications - Yoshitaka Yamaguchi
RIKEN Nishina Center, Wako 351-0198, Japan
4 shared publications A. Ozawa
Institute of Physics, University of Tsukuba, Tsukuba, 305-8571, Japan
3 shared publicationsD. Nagae
Laboratory for Zero-Carbon Energy, Tokyo Institute of Technology, Tokyo 152-8550, Japan
3 shared publications
Latest Publications
- 1 September 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (9) , 094003
Minimization method for accurate position-determination using a position-sensitive Schottky cavity doublet*
A position-sensitive Schottky Cavity Doublet (SCD) was developed to enhance the accuracy of isochronous mass measurement at the Rare Radio-Isotope Ring (R3) at RIBF-RIKEN, Japan. The aim is to increase the accuracy of position measurement, which is used to correct the momentum spread, thus reducing the uncertainty in the mass determination. The detector comprises a cylindrical reference cavity and elliptical position-sensitive cavity, which uses an offset beam-pipe to create a relation between the Schottky power and horizontal position. The uncertainty in the power response can be improved by minimizing free parameters inside the power equation, providing a second-order correction for the position determination. This requires a large dispersion and momentum spread to effectively characterize the SCD acceptance, which simulations show is achieved when using 76Zn as a reference isotope. A key parameter to minimize is uncertainty of the impedance map, which relates power to position in the elliptical cavity. We find that an uncertainty in impedance of 0.3 Ω results in a precision equal to that of the current mass measurement method. Additionally, measuring momentum with the SCD enables the removal of other detectors from the beam-line, which drastically reduces the yield of high-Z beams via charge-change interactions.
- 1 September 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (9) , 094003
Minimization method for accurate position-determination using a position-sensitive Schottky cavity doublet*
A position-sensitive Schottky Cavity Doublet (SCD) was developed to enhance the accuracy of isochronous mass measurement at the Rare Radio-Isotope Ring (R3) at RIBF-RIKEN, Japan. The aim is to increase the accuracy of position measurement, which is used to correct the momentum spread, thus reducing the uncertainty in the mass determination. The detector comprises a cylindrical reference cavity and elliptical position-sensitive cavity, which uses an offset beam-pipe to create a relation between the Schottky power and horizontal position. The uncertainty in the power response can be improved by minimizing free parameters inside the power equation, providing a second-order correction for the position determination. This requires a large dispersion and momentum spread to effectively characterize the SCD acceptance, which simulations show is achieved when using 76Zn as a reference isotope. A key parameter to minimize is uncertainty of the impedance map, which relates power to position in the elliptical cavity. We find that an uncertainty in impedance of 0.3 Ω results in a precision equal to that of the current mass measurement method. Additionally, measuring momentum with the SCD enables the removal of other detectors from the beam-line, which drastically reduces the yield of high-Z beams via charge-change interactions.
- 1 September 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (9) , 094002
Development status of efficiency improvement at the Rare-RI Ring facility*
The rare radioactive-isotope (RI) ring is an isochronous storage ring for deriving the masses of extremely short-lived rare RIs. Since the successful commissioning experiment in 2015, the time of flight mass measurement technique has been established through test experiments using unstable nuclei with well-known masses. The experiments for unknown masses were started in 2018. While conducting experiments, we continue to develop equipment to further improve the efficiency and precision of mass measurements. The upgraded kicker system can generate a magnetic field with an extractable duration equivalent to the revolution time of the ring. This is essential for extracting extremely rare events as well as shortening the measurement time compared with that in the initial experiments. New steering magnets make it possible to eliminate an uncertain vertical beam deviation that occurs upstream. As a result, we confirm that the extraction yield is increased. A new resonant Schottky pick-up is able to detect single particles in timeframes on the order of milliseconds. It will be useful not only for beam diagnostics but also for lifetime measurement experiments of extremely short-lived rare RIs planned as a future application.
- 1 September 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (9) , 094002
Development status of efficiency improvement at the Rare-RI Ring facility*
The rare radioactive-isotope (RI) ring is an isochronous storage ring for deriving the masses of extremely short-lived rare RIs. Since the successful commissioning experiment in 2015, the time of flight mass measurement technique has been established through test experiments using unstable nuclei with well-known masses. The experiments for unknown masses were started in 2018. While conducting experiments, we continue to develop equipment to further improve the efficiency and precision of mass measurements. The upgraded kicker system can generate a magnetic field with an extractable duration equivalent to the revolution time of the ring. This is essential for extracting extremely rare events as well as shortening the measurement time compared with that in the initial experiments. New steering magnets make it possible to eliminate an uncertain vertical beam deviation that occurs upstream. As a result, we confirm that the extraction yield is increased. A new resonant Schottky pick-up is able to detect single particles in timeframes on the order of milliseconds. It will be useful not only for beam diagnostics but also for lifetime measurement experiments of extremely short-lived rare RIs planned as a future application.
- 1 August 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (8) , 084007
Schottky detection techniques for ultra-rare short-lived ions in heavy-ion storage rings*
Non-destructive Schottky detectors are indispensable devices widely used in experiments at heavy-ion storage rings. In particular, they can be used to accurately determine the masses and lifetimes of short-lived exotic nuclear species. Single-ion sensitivity – which is the highest level of sensitivity – has been regularly achieved in the past by utilizing resonant cavity detectors. Recent designs and analysis methods aim to push the limits of measurement accuracy by increasing the dimensionality of the acquired data, namely, the position of the particle as well as the phase difference between several detectors. This paper describes current methods and future perspectives for Schottky detection techniques, with a focus on their application to mass and lifetime measurements of the most rare and simultaneously short-lived radio nuclides.
- 1 August 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (8) , 084007
Schottky detection techniques for ultra-rare short-lived ions in heavy-ion storage rings*
Non-destructive Schottky detectors are indispensable devices widely used in experiments at heavy-ion storage rings. In particular, they can be used to accurately determine the masses and lifetimes of short-lived exotic nuclear species. Single-ion sensitivity – which is the highest level of sensitivity – has been regularly achieved in the past by utilizing resonant cavity detectors. Recent designs and analysis methods aim to push the limits of measurement accuracy by increasing the dimensionality of the acquired data, namely, the position of the particle as well as the phase difference between several detectors. This paper describes current methods and future perspectives for Schottky detection techniques, with a focus on their application to mass and lifetime measurements of the most rare and simultaneously short-lived radio nuclides.
- Open Access
- 1 July 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (7) , 074005
Software defined radio for on-line interaction with beam processes in the heavy ion storage ring ESR*
The application of software defined radio in on-line interactions with the beam processes of the heavy ion storage ring is presented. We discusse how this new technique can enhance the beam time efficiency and create new measurement possibilities. A specific example to halt the accelerator running if a rare stored particle is identified on-line is discussed.
- 1 July 2025
- Published by IOP Publishing in Chinese Physics C
- Vol. 49 (7) , 074005
Open AccessSoftware defined radio for on-line interaction with beam processes in the heavy ion storage ring ESR*
The application of software defined radio in on-line interactions with the beam processes of the heavy ion storage ring is presented. We discusse how this new technique can enhance the beam time efficiency and create new measurement possibilities. A specific example to halt the accelerator running if a rare stored particle is identified on-line is discussed.
- Open Access
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Development of a low energy loss micro-channel plate based position-sensitive detector for the Rare Radio-Isotope Ring
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessDevelopment of a low energy loss micro-channel plate based position-sensitive detector for the Rare Radio-Isotope Ring
- 8 July 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (1) , 014607
Investigation of total reaction cross sections for proton-dripline nuclei and on a proton targetWe measured the total reaction cross section for the proton-dripline nucleus using a solid hydrogen target. Comparing the experimental results of and , on a proton target shows that the contribution of the isospin asymmetry of the nucleon-nucleon total cross section is more prominent than the changes in the nuclear radii of the two nuclei, while for a carbon target, the cross section simply reflects the nuclear matter radii of these isotopes, which are consistent with the results of previous theoretical works. The experimental values of for on a proton target at energies of several tens MeV/nucleon (several hundreds MeV/nucleon) are smaller (larger) than the theoretical values of ; similar trend is observed for . This discrepancy is not resolved at this time; therefore, further studies of the experimental and theoretical sides are required to precisely understand nucleus-proton collisions.- 8 July 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (1) , 014607
Investigation of total reaction cross sections for proton-dripline nuclei and on a proton targetWe measured the total reaction cross section for the proton-dripline nucleus using a solid hydrogen target. Comparing the experimental results of and , on a proton target shows that the contribution of the isospin asymmetry of the nucleon-nucleon total cross section is more prominent than the changes in the nuclear radii of the two nuclei, while for a carbon target, the cross section simply reflects the nuclear matter radii of these isotopes, which are consistent with the results of previous theoretical works. The experimental values of for on a proton target at energies of several tens MeV/nucleon (several hundreds MeV/nucleon) are smaller (larger) than the theoretical values of ; similar trend is observed for . This discrepancy is not resolved at this time; therefore, further studies of the experimental and theoretical sides are required to precisely understand nucleus-proton collisions.- 2 December 2021
- Published by Springer Nature in Hyperfine Interactions
- Vol. 242 (1) , 1-6
Application of spin polarized 19O beam to the study of oxygen motion in solid oxide fuel cell materials
- 2 December 2021
- Published by Springer Nature in Hyperfine Interactions
- Vol. 242 (1) , 1-6
Application of spin polarized 19O beam to the study of oxygen motion in solid oxide fuel cell materials