Zu-Xian Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zu-Xian Chen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Fen Miao
Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Shenzhen, China
1 shared publication - Jia Zeng
Huawei Technologies Company, Ltd., Shenzhen, China
1 shared publication - Jikui Liu
Institute of Intelligence Science and Engineering, Shenzhen Polytechnic University, No. 4089 Shahe West Road, Shenzhen, China
1 shared publication - Ye Li
Chinese Academy of Sciences
1 shared publication - Yuan-Ting Zhang
Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, SAR, China
1 shared publication - Zeng-Ding Liu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
1 shared publication
Latest Publications
- Top Cited Papers
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (7) , 3882-3894
HGCTNet: Handcrafted Feature-Guided CNN and Transformer Network for Wearable Cuffless Blood Pressure Measurement
Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 $\pm$ 6.5 mmHg for diastolic BP (DBP) and 0.7 $\pm$ 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are $-$ 0.4 $\pm$ 7.0 mmHg for DBP and $-$ 0.4 $\pm$ 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements. The dataset and source code are available at https://github.com/zdzdliu/HGCTNet.
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (7) , 3882-3894
Top Cited PapersHGCTNet: Handcrafted Feature-Guided CNN and Transformer Network for Wearable Cuffless Blood Pressure Measurement
Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 $\pm$ 6.5 mmHg for diastolic BP (DBP) and 0.7 $\pm$ 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are $-$ 0.4 $\pm$ 7.0 mmHg for DBP and $-$ 0.4 $\pm$ 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements. The dataset and source code are available at https://github.com/zdzdliu/HGCTNet.