Anton Verbytskiy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anton Verbytskiy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Serhii Sharapov
Sumy State University
4 shared publications - Danylo Husiev
Sumy State University
2 shared publications - Sviatoslav Yevtushenko
Sumy State University
2 shared publications - Dmytro Hopkalo
Department of Ecology and Environmental Protection Technologies, Sumy State University, 116, Kharkivska St., 40007 Sumy, Ukraine
1 shared publication - Iryna Vaskina
Department of Biosystems Engineering, Poznan University of Life Sciences, Wojska Polskiego 50, 60-627 Poznań, Poland
1 shared publication - Ivan Kozii
Department of Ecology and Environmental Protection Technologies, Sumy State University, 116 Kharkivska Street, 40007 Sumy, Ukraine
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by Publishing House Helvetica (Publications) in Scientific bulletin of the Tavria State Agrotechnological University
- Vol. 16 (1) , 149-160
ЕКСПЕРИМЕНТАЛЬНИЙ СТЕНД ДЛЯ ДОСЛІДЖЕННЯ ТЕПЛОЕЛЕКТРОГЕНЕРУЮЧИХ АГРЕГАТІВ НА БАЗІ РІДИННО-ПАРОВИХ СТРУМИННИХ АПАРАТІВ
У статті описано мету та завдання експериментальних досліджень теплоелектрогенеруючих агрегатів на базі рідинно-парових струминних апаратів. Для визначення завдань експериментальних досліджень було проведено критичний аналіз сучасного стану досліджень схемних рішень когенераційних систем для генерації теплової та електричної енергії, серед яких установки на базі міні-ТЕЦ та на базі теплових насосів. Отже, необхідно провести експериментальні дослідження пропонованого авторами теплоелектрогенеруючого агрегату на базі рідинно-парового струминного апарату, які б підтвердили проведені числові розрахунки та визначили режимні параметри, за яких його ефективність буде максимальною. У статті наведено схему та опис експериментальної установки для досліджень теплоелектрогенеруючих агрегатів на базі рідинно-парових струминних апаратів. Програма та методика містять діапазон зміни режимних та геометричних параметрів при проведенні експериментальних досліджень. Запропоновано схему підключення блоку конденсаторів до електрогенератора та наведено опис пропонованих контрольно-вимірювальних приладів в характерних точках циклах.
- 18 May 2026
- Published by Publishing House Helvetica (Publications) in Scientific bulletin of the Tavria State Agrotechnological University
- Vol. 16 (1) , 149-160
Open AccessЕКСПЕРИМЕНТАЛЬНИЙ СТЕНД ДЛЯ ДОСЛІДЖЕННЯ ТЕПЛОЕЛЕКТРОГЕНЕРУЮЧИХ АГРЕГАТІВ НА БАЗІ РІДИННО-ПАРОВИХ СТРУМИННИХ АПАРАТІВ
У статті описано мету та завдання експериментальних досліджень теплоелектрогенеруючих агрегатів на базі рідинно-парових струминних апаратів. Для визначення завдань експериментальних досліджень було проведено критичний аналіз сучасного стану досліджень схемних рішень когенераційних систем для генерації теплової та електричної енергії, серед яких установки на базі міні-ТЕЦ та на базі теплових насосів. Отже, необхідно провести експериментальні дослідження пропонованого авторами теплоелектрогенеруючого агрегату на базі рідинно-парового струминного апарату, які б підтвердили проведені числові розрахунки та визначили режимні параметри, за яких його ефективність буде максимальною. У статті наведено схему та опис експериментальної установки для досліджень теплоелектрогенеруючих агрегатів на базі рідинно-парових струминних апаратів. Програма та методика містять діапазон зміни режимних та геометричних параметрів при проведенні експериментальних досліджень. Запропоновано схему підключення блоку конденсаторів до електрогенератора та наведено опис пропонованих контрольно-вимірювальних приладів в характерних точках циклах.
- Open Access
- 23 October 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (11 (137)) , 6-14
Improving the efficiency of evaporation plants that produce condensed milk by applying liquid-vapor jet units
This study's object is the evaporation unit that produces condensed milk. The problem of low efficiency of evaporation units producing condensed milk has been solved by replacing steam jet ejectors with fundamentally new two-phase jet devices represented by liquid-vapor jet units. Their operational process is based on a jet thermocompression principle, which makes it possible to reduce the consumption of boiler steam, which is used in steam jet ejectors as a working jet of active flow. In liquid-vapor jet devices, boiler steam is used only to heat the working fluid of the active flow in a heat exchanger-heater. Given this, it is possible to reduce its consumption by 2.95 times and achieve the economic effect averaging USD 1,337. Another advantage of liquid-vapor jet units is that the generation of working steam occurs in the supersonic part of the active flow nozzle. As a result, it is possible to improve the degree of increase in the pressure of the secondary flow and abandon its multi-stage compression as is implemented in steam jet ejectors. This further increases the efficiency of installations based on such units by 25–30% compared to steam jet ejectors. And, most importantly, the use of liquid-vapor jet devices makes it possible to simplify the design of the evaporation unit and switch from a two-case to a single-case scheme. This provides a reduction in the cost of a product unit by an average of USD 450 per ton. This paper reports the thermodynamical, exergy, and thermoeconomic analyses. As a result of the study, it was found that the modernization of evaporation units that produce condensed milk by using liquid-vapor jet unit makes it possible to improve the efficiency of such systems by 2.1 times on average
- 23 October 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 5 (11 (137)) , 6-14
Open AccessImproving the efficiency of evaporation plants that produce condensed milk by applying liquid-vapor jet units
This study's object is the evaporation unit that produces condensed milk. The problem of low efficiency of evaporation units producing condensed milk has been solved by replacing steam jet ejectors with fundamentally new two-phase jet devices represented by liquid-vapor jet units. Their operational process is based on a jet thermocompression principle, which makes it possible to reduce the consumption of boiler steam, which is used in steam jet ejectors as a working jet of active flow. In liquid-vapor jet devices, boiler steam is used only to heat the working fluid of the active flow in a heat exchanger-heater. Given this, it is possible to reduce its consumption by 2.95 times and achieve the economic effect averaging USD 1,337. Another advantage of liquid-vapor jet units is that the generation of working steam occurs in the supersonic part of the active flow nozzle. As a result, it is possible to improve the degree of increase in the pressure of the secondary flow and abandon its multi-stage compression as is implemented in steam jet ejectors. This further increases the efficiency of installations based on such units by 25–30% compared to steam jet ejectors. And, most importantly, the use of liquid-vapor jet devices makes it possible to simplify the design of the evaporation unit and switch from a two-case to a single-case scheme. This provides a reduction in the cost of a product unit by an average of USD 450 per ton. This paper reports the thermodynamical, exergy, and thermoeconomic analyses. As a result of the study, it was found that the modernization of evaporation units that produce condensed milk by using liquid-vapor jet unit makes it possible to improve the efficiency of such systems by 2.1 times on average
- Open Access
Influence of Motive Nozzle Supersonic Part Profiling on the Effectiveness of the Vaporization Process: Experimental Results
This article presents experimental results for motive nozzles with profiled supersonic parts of parabolic, hyperbolic, and elliptical shapes, compared to conical nozzles with unprofiled supersonic parts. This study examined the effect of nozzle geometry and profile on thermodynamic and flow parameters of the vaporization process. The measured parameters included outlet pressure, flow velocity, and mass vapor content, along with dimensionless efficiency indicators, such as relative outflow velocity and the velocity coefficient. Graphical dependencies of these parameters on the relative initial underheating, (1 − εs0), were obtained. This parameter represents the ratio of the pressure difference between inlet and saturation conditions (at inlet temperature) to the inlet pressure. The results show that profiled nozzles operate effectively over a wider range of (1 − εs0) = 0.20–0.45, compared to conical unprofiled nozzles. The vaporization constant for profiled nozzles remained at bn ≈ (2/3)0.5 along their length. The velocity coefficients for profiled designs were 4–6% higher, and the volumetric vapor content at the outlet was also greater, indicating a more efficient vaporization process. Overall, the findings demonstrate that profiling the supersonic section of a motive nozzle improves the operating range, flow characteristics, and vaporization quality compared to conventional conical designs.
Open AccessInfluence of Motive Nozzle Supersonic Part Profiling on the Effectiveness of the Vaporization Process: Experimental Results
This article presents experimental results for motive nozzles with profiled supersonic parts of parabolic, hyperbolic, and elliptical shapes, compared to conical nozzles with unprofiled supersonic parts. This study examined the effect of nozzle geometry and profile on thermodynamic and flow parameters of the vaporization process. The measured parameters included outlet pressure, flow velocity, and mass vapor content, along with dimensionless efficiency indicators, such as relative outflow velocity and the velocity coefficient. Graphical dependencies of these parameters on the relative initial underheating, (1 − εs0), were obtained. This parameter represents the ratio of the pressure difference between inlet and saturation conditions (at inlet temperature) to the inlet pressure. The results show that profiled nozzles operate effectively over a wider range of (1 − εs0) = 0.20–0.45, compared to conical unprofiled nozzles. The vaporization constant for profiled nozzles remained at bn ≈ (2/3)0.5 along their length. The velocity coefficients for profiled designs were 4–6% higher, and the volumetric vapor content at the outlet was also greater, indicating a more efficient vaporization process. Overall, the findings demonstrate that profiling the supersonic section of a motive nozzle improves the operating range, flow characteristics, and vaporization quality compared to conventional conical designs.
- Open Access
- 1 January 2024
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 11 (2) , G1-G8
Heat Utilization in Boiler Plants by Using Liquid-Vapor Jet Apparatus
The article solves the problem of heat utilization from combustion products in boiler plants. The proposed solution involves extracting heat to preheat the network water for the heating system and implementing additional heat utilization using a liquid-vapor jet apparatus. This will allow for additional working steam generation in the main steam generator and the unit based on the liquid-vapor jet apparatus. The article provides schemes and descriptions of traditional and proposed plants, indicating their design differences from the basic scheme. Comparative thermodynamic analysis of the proposed installation for additional recuperative heat utilization and the basic scheme is carried out, in which heat utilization occurs due to the extraction of heat from combustion products to preheat the network water of the heating system. As a result, the main thermodynamic parameters of the cycles of basic and proposed schemes are obtained, and the values of the capacities on the apparatuses included in these installations are determined. The energetic potential obtained from additional heat utilization is 8 %, which can be used for electricity generation. Exergy analysis assesses the efficiency of additional heat utilization in boiler plants using units based on liquid-vapor jet apparatus. As a result of the exergy analysis, the value of the exergetic efficiency of the scheme with additional heat utilization was obtained, which is 1.47 times higher than that of the basic scheme. A thermoeconomic analysis was performed to determine the cost values. Implementing the new scheme enables reducing the specific cost of the heating unit by 48 % and increasing the amount of steam generated in the installation by an additional 18 %.
- 1 January 2024
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 11 (2) , G1-G8
Open AccessHeat Utilization in Boiler Plants by Using Liquid-Vapor Jet Apparatus
The article solves the problem of heat utilization from combustion products in boiler plants. The proposed solution involves extracting heat to preheat the network water for the heating system and implementing additional heat utilization using a liquid-vapor jet apparatus. This will allow for additional working steam generation in the main steam generator and the unit based on the liquid-vapor jet apparatus. The article provides schemes and descriptions of traditional and proposed plants, indicating their design differences from the basic scheme. Comparative thermodynamic analysis of the proposed installation for additional recuperative heat utilization and the basic scheme is carried out, in which heat utilization occurs due to the extraction of heat from combustion products to preheat the network water of the heating system. As a result, the main thermodynamic parameters of the cycles of basic and proposed schemes are obtained, and the values of the capacities on the apparatuses included in these installations are determined. The energetic potential obtained from additional heat utilization is 8 %, which can be used for electricity generation. Exergy analysis assesses the efficiency of additional heat utilization in boiler plants using units based on liquid-vapor jet apparatus. As a result of the exergy analysis, the value of the exergetic efficiency of the scheme with additional heat utilization was obtained, which is 1.47 times higher than that of the basic scheme. A thermoeconomic analysis was performed to determine the cost values. Implementing the new scheme enables reducing the specific cost of the heating unit by 48 % and increasing the amount of steam generated in the installation by an additional 18 %.