Chunxiao Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chunxiao Yan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Lijun Zhang
Dalian Medical University, Dalian, China
2 shared publications Lin Jin
Department of Ophthalmology, The Third People’s Hospital Affiliated to Dalian University of Technology, Dalian, Liaoning, People’s Republic of China
2 shared publicationsBingqian Wu
1 shared publication- Chao Li
School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China
1 shared publication Chuanfeng An
1 shared publication- Chunmei Li
Tsinghua International School Daoxiang Lake 4 , Beijing 100194
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-12
Wear-Related Visible Surface Alteration and Pseudomonas aeruginosa Adhesion in Orthokeratology Lenses
Purpose: To compare grayscale-derived visible surface characteristics and Pseudomonas aeruginosa adhesion between unworn orthokeratology lenses and lenses worn for approximately 12 months, and to explore associations between grayscale-derived parameters and bacterial adhesion. Methods: Sixty orthokeratology lenses were analyzed, including 20 unworn lenses and 40 lenses worn for approximately 12 months. Each worn lens was collected from a different wearer during routine replacement. Standardized slit-lamp images were analyzed with ImageJ to obtain mean gray value and gray-level standard deviation within the central 6.0-mm optical zone. In vitro P. aeruginosa adhesion was quantified as log10-transformed colony-forming units. Group differences were assessed using two-way ANOVA followed by exploratory simple-effect comparisons with Holm adjustment, and correlations between grayscale-derived parameters and bacterial adhesion were explored among worn lenses. Results: Clinical wear was associated with significantly higher mean gray value, gray-level standard deviation, and P. aeruginosa adhesion compared with unworn lenses (all P < 0.001). Exploratory simple-effect comparisons identified higher mean gray value and bacterial adhesion in worn type A than worn type Z lenses after Holm correction, whereas the gray-level standard deviation difference did not remain significant after correction. None of the wear × lens-system interaction terms in the primary ANOVA was statistically significant. Grayscale-derived parameters were only weakly correlated with bacterial adhesion, and these associations were not significant after correction for multiple testing. Conclusion: Orthokeratology lenses worn for approximately 12 months showed greater grayscale-derived visible surface alteration and higher P. aeruginosa adhesion than unworn lenses. These laboratory findings do not establish an increased clinical infection risk or an optimal replacement interval and require prospective clinical validation.
- 1 September 2026
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 18, 1-12
Open AccessWear-Related Visible Surface Alteration and Pseudomonas aeruginosa Adhesion in Orthokeratology Lenses
Purpose: To compare grayscale-derived visible surface characteristics and Pseudomonas aeruginosa adhesion between unworn orthokeratology lenses and lenses worn for approximately 12 months, and to explore associations between grayscale-derived parameters and bacterial adhesion. Methods: Sixty orthokeratology lenses were analyzed, including 20 unworn lenses and 40 lenses worn for approximately 12 months. Each worn lens was collected from a different wearer during routine replacement. Standardized slit-lamp images were analyzed with ImageJ to obtain mean gray value and gray-level standard deviation within the central 6.0-mm optical zone. In vitro P. aeruginosa adhesion was quantified as log10-transformed colony-forming units. Group differences were assessed using two-way ANOVA followed by exploratory simple-effect comparisons with Holm adjustment, and correlations between grayscale-derived parameters and bacterial adhesion were explored among worn lenses. Results: Clinical wear was associated with significantly higher mean gray value, gray-level standard deviation, and P. aeruginosa adhesion compared with unworn lenses (all P < 0.001). Exploratory simple-effect comparisons identified higher mean gray value and bacterial adhesion in worn type A than worn type Z lenses after Holm correction, whereas the gray-level standard deviation difference did not remain significant after correction. None of the wear × lens-system interaction terms in the primary ANOVA was statistically significant. Grayscale-derived parameters were only weakly correlated with bacterial adhesion, and these associations were not significant after correction for multiple testing. Conclusion: Orthokeratology lenses worn for approximately 12 months showed greater grayscale-derived visible surface alteration and higher P. aeruginosa adhesion than unworn lenses. These laboratory findings do not establish an increased clinical infection risk or an optimal replacement interval and require prospective clinical validation.
- Open Access
- 1 July 2024
- Published by American Vacuum Society in Biointerphases
- Vol. 19 (4)
Drug-eluting contact lenses: Progress, challenges, and prospects
Topical ophthalmic solutions (eye drops) are becoming increasingly popular in treating and preventing ocular diseases for their safety, noninvasiveness, and ease of handling. However, the static and dynamic barriers of eyes cause the extremely low bioavailability (<5%) of eye drops, making ocular therapy challenging. Thus, drug-eluting corneal contact lenses (DECLs) have been intensively investigated as a drug delivery device for their attractive properties, such as sustained drug release and improved bioavailability. In order to promote the clinical application of DECLs, multiple aspects, i.e., drug release and penetration, safety, and biocompatibility, of these drug delivery systems were thoroughly examined. In this review, we systematically discussed advances in DECLs, including types of preparation materials, drug-loading strategies, drug release mechanisms, strategies for penetrating ocular barriers, in vitro and in vivo drug delivery and penetration detection, safety, and biocompatibility validation methods, as well as challenges and future perspectives.
- 1 July 2024
- Published by American Vacuum Society in Biointerphases
- Vol. 19 (4)
Open AccessDrug-eluting contact lenses: Progress, challenges, and prospects
Topical ophthalmic solutions (eye drops) are becoming increasingly popular in treating and preventing ocular diseases for their safety, noninvasiveness, and ease of handling. However, the static and dynamic barriers of eyes cause the extremely low bioavailability (<5%) of eye drops, making ocular therapy challenging. Thus, drug-eluting corneal contact lenses (DECLs) have been intensively investigated as a drug delivery device for their attractive properties, such as sustained drug release and improved bioavailability. In order to promote the clinical application of DECLs, multiple aspects, i.e., drug release and penetration, safety, and biocompatibility, of these drug delivery systems were thoroughly examined. In this review, we systematically discussed advances in DECLs, including types of preparation materials, drug-loading strategies, drug release mechanisms, strategies for penetrating ocular barriers, in vitro and in vivo drug delivery and penetration detection, safety, and biocompatibility validation methods, as well as challenges and future perspectives.