Madeline Cancian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Madeline Cancian has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kamil Malshy
Department of Urology, University of Rochester Medical Center, Rochester, NY
4 shared publications - Borivoj Golijanin
The Minimally Invasive Urology Institute, The Miriam Hospital, Providence, RI, US; The Warren Alpert Medical School of Brown University, Providence, RI, US
3 shared publications - Edouard Nicaise
Department of Urology, Emory University Hospital, Atlanta, Georgia, US
3 shared publications - Kennon Miller
The Minimally Invasive Urology Institute, The Miriam Hospital, Providence, RI, US; The Warren Alpert Medical School of Brown University, Providence, RI, US
3 shared publications - Lindsey Hartsell
Department of Urology, Emory University Hospital, Atlanta, Georgia, US
3 shared publications - Rebecca Ortiz
The Minimally Invasive Urology Institute, The Miriam Hospital, Providence, RI, US
3 shared publications
Latest Publications
- 10 July 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-7
Comparing the lifespan of virgin artificial urinary sphincters in radiated patients: transcorporal vs. standard placement
Purpose To compare the lifespan of first transcorporal cuff (TC) placement of an artificial urinary sphincter (AUS) versus standard placement (SP) in patients with prior radiotherapy (RT) for prostate cancer (PCa). Methods We reviewed first (virgin) AUS placements from two high-volume care centers between 1/2011 and 1/2021, including PCa patients with RT history. AUS lifespan was assessed via the hazard ratio of device explantation and/or revision within a ten-year timeframe for the TC vs. SP approaches. Chi-square, Fisher’s exact, and t-tests compared clinicodemographic variables. Kaplan-Meier curve compared TC and SP lifespan. Results 85/314 men with AUS met inclusion criteria, with 38.8% (33/85) in the TC group and 61.2% (52/85) in the SP group. Median ages were 69.8 (IQR = 65.2–73.6) and 67.1 (61.6–72.9), respectively, p = 0.17. Over a median follow up of 51.9 (15.8–86.1) and 80.4 (28.1–128.3) months for the TC and SP, overall, 12 (36.4%) TC devices were removed (four [12.1%] due to mechanical failures; eight [24.2%] erosions, and two [6.1%] infections) vs. 29 (55.8%) in the SP group (14 [26.9%] mechanical failures; 11 [21.1%] erosions, and five [9.6%] infections). No statistically significant differences were observed between the two approaches, with HR = 0.717, 95% CI 0.37–1.44, p = 0.35. The calculated device survival probabilities for the TC vs. SP at one, five, and 10 years were 78.8% vs. 76.9%, 69.3% vs. 58.7%, and 62.1% vs. 46.7%, respectively. Conclusions TC cuff insertion for the first AUS implantation in pre-radiated patients showed to be comparable to SP when it comes to device survival, with comparable complication rates. Current guidance for approach selection is primarily based on patient selection and surgeon preference.
- 10 July 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-7
Comparing the lifespan of virgin artificial urinary sphincters in radiated patients: transcorporal vs. standard placement
Purpose To compare the lifespan of first transcorporal cuff (TC) placement of an artificial urinary sphincter (AUS) versus standard placement (SP) in patients with prior radiotherapy (RT) for prostate cancer (PCa). Methods We reviewed first (virgin) AUS placements from two high-volume care centers between 1/2011 and 1/2021, including PCa patients with RT history. AUS lifespan was assessed via the hazard ratio of device explantation and/or revision within a ten-year timeframe for the TC vs. SP approaches. Chi-square, Fisher’s exact, and t-tests compared clinicodemographic variables. Kaplan-Meier curve compared TC and SP lifespan. Results 85/314 men with AUS met inclusion criteria, with 38.8% (33/85) in the TC group and 61.2% (52/85) in the SP group. Median ages were 69.8 (IQR = 65.2–73.6) and 67.1 (61.6–72.9), respectively, p = 0.17. Over a median follow up of 51.9 (15.8–86.1) and 80.4 (28.1–128.3) months for the TC and SP, overall, 12 (36.4%) TC devices were removed (four [12.1%] due to mechanical failures; eight [24.2%] erosions, and two [6.1%] infections) vs. 29 (55.8%) in the SP group (14 [26.9%] mechanical failures; 11 [21.1%] erosions, and five [9.6%] infections). No statistically significant differences were observed between the two approaches, with HR = 0.717, 95% CI 0.37–1.44, p = 0.35. The calculated device survival probabilities for the TC vs. SP at one, five, and 10 years were 78.8% vs. 76.9%, 69.3% vs. 58.7%, and 62.1% vs. 46.7%, respectively. Conclusions TC cuff insertion for the first AUS implantation in pre-radiated patients showed to be comparable to SP when it comes to device survival, with comparable complication rates. Current guidance for approach selection is primarily based on patient selection and surgeon preference.