Young-Jin Cho
Research Subjects
Young-Jin Cho has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chikahiro Ohkubo
Department of Oral Rehabilitation and Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama 230-8501, Japan
4 shared publications - Gabriele Cervino
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Messina, Italy
4 shared publications - Gaetano Noè
Adjunct Professor, Dental School, Department of Medicine and Surgery, University of Parma, Parma, Italy, Italy
4 shared publications - Kwantae Noh
School of Dentistry, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun District, Seoul 02447, Republic of Korea
4 shared publications - Marco Tallarico
Department of Medicine, Surgery, and Pharmacy, University of Sassari, 07100 Sassari, Italy
4 shared publications - Recep Uzgur
Independent Researcher, Kocaeli 41950, Türkiye
4 shared publications
Latest Publications
- Open Access
- 18 February 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (2) , 18
Factors Affecting the Implant Supracrestal Complex: A Consensus Paper from the Global Consensus Meeting Organized by the Osstem Implant Community
Aim: To develop clear, evidence-based, and standardized guidelines for the design, selection, and clinical use of implant abutments and prosthetic components in order to optimize the biological, mechanical, and esthetic performance of the implant supracrestal complex. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. For the present consensus meeting, a scoping review was performed in advance and discussed among the participants. A comprehensive search of the literature was performed up to June 2025. Two reviewers (M.T. and F.G.) independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The evidence was synthesized and discussed by the panel of expert clinicians during the consensus meeting. After that, guidelines were developed using a 14-question questionnaire to formulate consensus-based clinical recommendations. The participants answered structured questions and discussed discrepancies to achieve a consensus. Results: The panel of expert clinicians reached a consensus on several prosthetic key points. Concave abutment profiles and emergence angles <30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, while zirconia provides superior esthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. The evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.
- 18 February 2026
- Published by MDPI AG in Prosthesis
- Vol. 8 (2) , 18
Open AccessFactors Affecting the Implant Supracrestal Complex: A Consensus Paper from the Global Consensus Meeting Organized by the Osstem Implant Community
Aim: To develop clear, evidence-based, and standardized guidelines for the design, selection, and clinical use of implant abutments and prosthetic components in order to optimize the biological, mechanical, and esthetic performance of the implant supracrestal complex. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. For the present consensus meeting, a scoping review was performed in advance and discussed among the participants. A comprehensive search of the literature was performed up to June 2025. Two reviewers (M.T. and F.G.) independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The evidence was synthesized and discussed by the panel of expert clinicians during the consensus meeting. After that, guidelines were developed using a 14-question questionnaire to formulate consensus-based clinical recommendations. The participants answered structured questions and discussed discrepancies to achieve a consensus. Results: The panel of expert clinicians reached a consensus on several prosthetic key points. Concave abutment profiles and emergence angles <30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, while zirconia provides superior esthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. The evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.
- Open Access
- 28 November 2025
- Published by MDPI AG in Preprints.org
Factors Affecting the Implant Supracrestal Complex: A Scoping Review as Part of a Global Consensus Meeting Organised by the Osstem Implant Community
Aim: To map current evidence and identify key factors influencing peri-implant tissue stability related to abutment configuration, design, materials, and prosthetic protocols in implant-supported fixed prostheses. Methods: A comprehensive search of PubMed and Scopus was performed up to June 2025, supplemented by manual searches. Human studies in English with ≥1 year of follow-up were included. Two reviewers independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The review was carried out at the Universities of Sassari and Ferrara in collaboration with the Osstem Global Consensus Meeting. Results: From 974 records, 46 studies were included: 33 randomized clinical trials, 9 cohort, 2 case-control, and 2 cross-sectional studies. Thirty-nine were rated as good quality and five as fair. Concave abutment profiles and emergence angles < 30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, zirconia provides superior aesthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. Evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.
- 28 November 2025
- Published by MDPI AG in Preprints.org
Open AccessFactors Affecting the Implant Supracrestal Complex: A Scoping Review as Part of a Global Consensus Meeting Organised by the Osstem Implant Community
Aim: To map current evidence and identify key factors influencing peri-implant tissue stability related to abutment configuration, design, materials, and prosthetic protocols in implant-supported fixed prostheses. Methods: A comprehensive search of PubMed and Scopus was performed up to June 2025, supplemented by manual searches. Human studies in English with ≥1 year of follow-up were included. Two reviewers independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The review was carried out at the Universities of Sassari and Ferrara in collaboration with the Osstem Global Consensus Meeting. Results: From 974 records, 46 studies were included: 33 randomized clinical trials, 9 cohort, 2 case-control, and 2 cross-sectional studies. Thirty-nine were rated as good quality and five as fair. Concave abutment profiles and emergence angles < 30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, zirconia provides superior aesthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. Evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.
- Open Access
- 16 June 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 65
Prosthetic Guidelines to Prevent Implant Fracture and Peri-Implantitis: A Consensus Statement from the Osstem Implant Community
Background: While dental implants have become a reliable solution for tooth loss, their long-term success is increasingly challenged by biological and technical complications such as impact fracture and peri-implantitis. These complications significantly impact implant longevity and patient satisfaction. Aim: This consensus conference aimed to identify and standardize clinical guidelines to prevent implant fractures and peri-implant diseases based on current evidence and expert opinions. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. This paper focuses on the prosthetic division. A structured literature review was conducted, and evidence was synthesized to formulate consensus-based clinical recommendations. Participants answered structured questions and discussed discrepancies to achieve consensus. Results: The panel reached consensus on several key prosthetic risk factors, including (1) the role of biomechanical overload in implant fracture, (2) the impact of emergence profile design on peri-implant tissue stability, (3) the influence of implant positioning and connection geometry on marginal bone loss, and (4) the importance of occlusal scheme and restorative material selection, particularly in high-risk patients such as bruxers. Guidelines to prevent implant fracture and peri-implantitis were developed, addressing these factors with practical preventive strategies. Conclusions: Despite the limitations of narrative methodology and reliance on retrospective data and expert opinion, this consensus provides clinically relevant guidelines to aid in the prevention of mechanical failures and peri-implant diseases. The recommendations emphasize prosthetically driven planning, individualized risk assessment, and early intervention to support long-term implant success.
- 16 June 2025
- Published by MDPI AG in Prosthesis
- Vol. 7 (3) , 65
Open AccessProsthetic Guidelines to Prevent Implant Fracture and Peri-Implantitis: A Consensus Statement from the Osstem Implant Community
Background: While dental implants have become a reliable solution for tooth loss, their long-term success is increasingly challenged by biological and technical complications such as impact fracture and peri-implantitis. These complications significantly impact implant longevity and patient satisfaction. Aim: This consensus conference aimed to identify and standardize clinical guidelines to prevent implant fractures and peri-implant diseases based on current evidence and expert opinions. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. This paper focuses on the prosthetic division. A structured literature review was conducted, and evidence was synthesized to formulate consensus-based clinical recommendations. Participants answered structured questions and discussed discrepancies to achieve consensus. Results: The panel reached consensus on several key prosthetic risk factors, including (1) the role of biomechanical overload in implant fracture, (2) the impact of emergence profile design on peri-implant tissue stability, (3) the influence of implant positioning and connection geometry on marginal bone loss, and (4) the importance of occlusal scheme and restorative material selection, particularly in high-risk patients such as bruxers. Guidelines to prevent implant fracture and peri-implantitis were developed, addressing these factors with practical preventive strategies. Conclusions: Despite the limitations of narrative methodology and reliance on retrospective data and expert opinion, this consensus provides clinically relevant guidelines to aid in the prevention of mechanical failures and peri-implant diseases. The recommendations emphasize prosthetically driven planning, individualized risk assessment, and early intervention to support long-term implant success.
- Open Access
- 9 June 2025
- Published by MDPI AG in Preprints.org
Prosthetic Guidelines to Prevent Implant Fracture and Peri‐Implantitis: A Consensus Statement from the Osstem Implant Community
Dental implants have become a cornerstone in restorative dentistry, offering effective solutions for tooth loss. However, their long-term success is often challenged by both biological and technical complications that can affect implant longevity and patient satisfaction. Biological complications, such as peri-implantitis, are characterized by inflammation and bone loss around the implant, leading to implant failure if left unmanaged. Peri-implant bone loss greater than 2 mm occurs in a significant portion of cases, with rates of 20.1% after five years and 40.3% after ten years. Technical complications, including screw fractures and prosthetic issues like chipping, also contribute to implant failure. The etiology of implant fractures is multifactorial, with biomechanical overload, material fatigue, implant design, and patient-related factors such as bruxism playing significant roles. Advances in implant materials and surface modifications aim to reduce these risks, yet cases of implant fractures continue to be reported, underlining the need for improved diagnostic, preventive, and management strategies. Peri-implant diseases, including peri-implantitis, are also on the rise, with patient-, surgical-, and prosthetic-related factors contributing to their development. To address these challenges, this narrative review synthesizes current evidence on the risk factors, prevention strategies, and management approaches for both biological and technical complications associated with dental implants. Through a systematic approach, a consensus was reached during the Osstem Global Consensus Meeting, providing updated guidelines to support clinicians in enhancing the long-term success of dental implants. These guidelines emphasize the prevention of mechanical failures, peri-implant diseases, and the importance of early detection and intervention.
- 9 June 2025
- Published by MDPI AG in Preprints.org
Open AccessProsthetic Guidelines to Prevent Implant Fracture and Peri‐Implantitis: A Consensus Statement from the Osstem Implant Community
Dental implants have become a cornerstone in restorative dentistry, offering effective solutions for tooth loss. However, their long-term success is often challenged by both biological and technical complications that can affect implant longevity and patient satisfaction. Biological complications, such as peri-implantitis, are characterized by inflammation and bone loss around the implant, leading to implant failure if left unmanaged. Peri-implant bone loss greater than 2 mm occurs in a significant portion of cases, with rates of 20.1% after five years and 40.3% after ten years. Technical complications, including screw fractures and prosthetic issues like chipping, also contribute to implant failure. The etiology of implant fractures is multifactorial, with biomechanical overload, material fatigue, implant design, and patient-related factors such as bruxism playing significant roles. Advances in implant materials and surface modifications aim to reduce these risks, yet cases of implant fractures continue to be reported, underlining the need for improved diagnostic, preventive, and management strategies. Peri-implant diseases, including peri-implantitis, are also on the rise, with patient-, surgical-, and prosthetic-related factors contributing to their development. To address these challenges, this narrative review synthesizes current evidence on the risk factors, prevention strategies, and management approaches for both biological and technical complications associated with dental implants. Through a systematic approach, a consensus was reached during the Osstem Global Consensus Meeting, providing updated guidelines to support clinicians in enhancing the long-term success of dental implants. These guidelines emphasize the prevention of mechanical failures, peri-implant diseases, and the importance of early detection and intervention.
- Open Access
- 30 September 2023
- Published by Korean Dental Association in Journal of Korean Dental Association
- Vol. 61 (9) , 591-600
Necessity of Minor Tooth Movement For Restoration of Implant Prosthesis
When attempting to place a dental implant in a missing area, there is often not enough room for the restoration because the surrounding teeth are tilted toward the missing area, there is an diastema, or the antagonistic teeth are extruding into the edentulous space. To create a functional and aesthetically pleasing prosthesis in suchcases, it is essential to pre-establish a sufficient and normal-sized restorative space to achieve a more naturallooking restoration. As part of the pre-implant treatment process, minor tooth movements can be performed to achieve this goal. The importance of orthodontic treatment in relation to implant therapy is often overlooked, but simple orthodontic tooth movements of adjacent teeth before the completion of implant prostheses can yield significant improvements. Implant therapy performed without correcting abnormal spaces can lead to vari-ous biological and mechanical complications, highlighting the substantial value of such orthodontic treatment. Here, representative cases encountered in clinical practice involving common horizontal and vertical space is-sues and their resolution through orthodontic intervention before completing implant prosthodontic procedure will be introduced.
- 30 September 2023
- Published by Korean Dental Association in Journal of Korean Dental Association
- Vol. 61 (9) , 591-600
Open AccessNecessity of Minor Tooth Movement For Restoration of Implant Prosthesis
When attempting to place a dental implant in a missing area, there is often not enough room for the restoration because the surrounding teeth are tilted toward the missing area, there is an diastema, or the antagonistic teeth are extruding into the edentulous space. To create a functional and aesthetically pleasing prosthesis in suchcases, it is essential to pre-establish a sufficient and normal-sized restorative space to achieve a more naturallooking restoration. As part of the pre-implant treatment process, minor tooth movements can be performed to achieve this goal. The importance of orthodontic treatment in relation to implant therapy is often overlooked, but simple orthodontic tooth movements of adjacent teeth before the completion of implant prostheses can yield significant improvements. Implant therapy performed without correcting abnormal spaces can lead to vari-ous biological and mechanical complications, highlighting the substantial value of such orthodontic treatment. Here, representative cases encountered in clinical practice involving common horizontal and vertical space is-sues and their resolution through orthodontic intervention before completing implant prosthodontic procedure will be introduced.