Adrian Radomski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adrian Radomski has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Teichmann
SDU Health Informatics and Technology, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Odense, Denmark
2 shared publications - Abdullah Eroglu
State University of New York Polytechnic Institute, Utica, New York, USA
1 shared publication - Akinori Ueno
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication D. Lincoln
MKS Instruments, ENI Products , Rochester, NY, 14623, USA
1 shared publication- Koki Oshima
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication - Masaki Arai
Department of Electrical and Electronic Engineering, Tokyo Denki University, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4157-4166
Reflective PPG Sensor Measures Heart Rate Through Clothing During Driving
This paper presents the development and validation of a reflective photoplethysmography (PPG) sensor designed for unobtrusive heart rate monitoring through clothing in automotive environments. The sensor is integrated into the backrest of a car seat and employs an optimized hardware configuration to enhance signal acquisition and mitigate motion artifacts during driving. Its performance was evaluated in two scenarios: a validation study with 12 participants driving for a total of 316 minutes and a longitudinal field study encompassing 1080 minutes of driving across three European countries. The validation study demonstrated a concordance correlation coefficient (CCC) of 0.89, a mean absolute error (MAE) of 2.51 bpm, and a mean absolute percentage error (MAPE) of 3.07%. Gender-specific analysis revealed minimal differences in performance, with an overall coverage rate of 77.60%. The longitudinal study confirmed the sensor’s reliability over prolonged periods, achieving a CCC of 0.976, MAE of 0.844 bpm, and MAPE of 1.04%, with a 95.92% coverage rate across diverse driving conditions.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4157-4166
Open AccessReflective PPG Sensor Measures Heart Rate Through Clothing During Driving
This paper presents the development and validation of a reflective photoplethysmography (PPG) sensor designed for unobtrusive heart rate monitoring through clothing in automotive environments. The sensor is integrated into the backrest of a car seat and employs an optimized hardware configuration to enhance signal acquisition and mitigate motion artifacts during driving. Its performance was evaluated in two scenarios: a validation study with 12 participants driving for a total of 316 minutes and a longitudinal field study encompassing 1080 minutes of driving across three European countries. The validation study demonstrated a concordance correlation coefficient (CCC) of 0.89, a mean absolute error (MAE) of 2.51 bpm, and a mean absolute percentage error (MAPE) of 3.07%. Gender-specific analysis revealed minimal differences in performance, with an overall coverage rate of 77.60%. The longitudinal study confirmed the sensor’s reliability over prolonged periods, achieving a CCC of 0.976, MAE of 0.844 bpm, and MAPE of 1.04%, with a 95.92% coverage rate across diverse driving conditions.
- Open Access
On-Road Evaluation of Unobtrusive In-Car Respiration Monitoring
This paper introduces and evaluates an innovative sensor for unobtrusive in-car respiration monitoring, mounted on the backrest of the driver’s seat. The sensor seamlessly integrates into the vehicle, measuring breathing rates continuously without requiring active participation from the driver. The paper proves the feasibility of unobtrusive in-car measurements over long periods of time. Operation of the sensor was investigated over 12 participants sitting in the driver seat. A total of 107 min of driving in diverse conditions with overall coverage rate of 84.45% underscores the sensor potential to reliably capture physiological changes in breathing rate for fatigue and stress detection.
Open AccessOn-Road Evaluation of Unobtrusive In-Car Respiration Monitoring
This paper introduces and evaluates an innovative sensor for unobtrusive in-car respiration monitoring, mounted on the backrest of the driver’s seat. The sensor seamlessly integrates into the vehicle, measuring breathing rates continuously without requiring active participation from the driver. The paper proves the feasibility of unobtrusive in-car measurements over long periods of time. Operation of the sensor was investigated over 12 participants sitting in the driver seat. A total of 107 min of driving in diverse conditions with overall coverage rate of 84.45% underscores the sensor potential to reliably capture physiological changes in breathing rate for fatigue and stress detection.
- 5 April 2007
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 94 (4) , 391-402
New topology for Class E amplifiers
A Class E RF amplifier, which can operate into any load conditions without need for other additional circuitry to protect transistors, is introduced. This is provided by the new topology, which is called an inductive clamp. Our topology incorporates inductive clamp circuitry to the basic Class E amplifier circuit and it has all the benefits of Class E amplifiers. Additionally, it has inherent self-protection that comes with the inductive clamp circuit. A Class E amplifier with the new topology is designed, simulated and implemented. The experimental results are presented and found to be very close to the simulated results. The amplifier drain efficiency is measured around 88% at the rated power level and it is confirmed that the amplifier protected itself and was stable over entire VSWR and dynamic range within the bandwidth of operational frequency. Class E amplifiers with this topology can be used in applications where the load conditions are dynamic.
- 5 April 2007
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 94 (4) , 391-402
New topology for Class E amplifiers
A Class E RF amplifier, which can operate into any load conditions without need for other additional circuitry to protect transistors, is introduced. This is provided by the new topology, which is called an inductive clamp. Our topology incorporates inductive clamp circuitry to the basic Class E amplifier circuit and it has all the benefits of Class E amplifiers. Additionally, it has inherent self-protection that comes with the inductive clamp circuit. A Class E amplifier with the new topology is designed, simulated and implemented. The experimental results are presented and found to be very close to the simulated results. The amplifier drain efficiency is measured around 88% at the rated power level and it is confirmed that the amplifier protected itself and was stable over entire VSWR and dynamic range within the bandwidth of operational frequency. Class E amplifiers with this topology can be used in applications where the load conditions are dynamic.