ASAlexander Sudakov

Alexander Sudakov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander Sudakov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • APPLICATION OF A THERMAL IMAGING MODULE FOR MONITORING THE TECHNICAL CONDITION OF AN INCUBATOR

    by Evgeniy Andrianov, Alexander Sudakov, Aleksey Andrianov, Oksana Lipa

    Trouble-free operation of all units and components in industrial incubators is key to achieving high hatchability rates and quality of young poultry. The article presents the results of an experiment studying the possibility of using a thermal imaging module to monitor the technical condition of an incubator. A thermal imaging module MLX90640 with a resolution of 32×24 pixels, connected to an ESP8266 microcontroller, was installed in the chamber of a REMIL-1000 incubator. Data were transmitted to the server via Wi-Fi at 1-minute intervals. As a result of monitoring, a dataset was formed, including 10,821 rows and about 8 million temperature values. Data processing was carried out using Python program code. It was established that the use of a reference thermal map for assessing the condition of electrical and mechanical units of the incubator has low informativeness, since the temperature characteristics of surfaces inside the incubator change during the operation of the heating elements. A method is proposed for processing real-time temperature data based on automatic identification of regions of interest and calculation of statistical characteristics of the obtained data. As a result of processing, three regions of interest were identified. The average temperature in ROI_1 was 38.21 °C, in ROI_2 – 35.27 °C, and in ROI_3 – 38.39 °C. The maximum recorded values were 145.13, 74.57, and 132.65 °C, respectively. It was established that a low-resolution thermal imaging module can be used not only for visual temperature control, but also as an element of a system for monitoring the operation of individual incubator units.

  • DETERMINATION OF INCUBATOR VENTILATION INTENSITY BY THE DYNAMICS OF WATER FLOW RATE IN THE HUMIDIFIER

    by Moscow State Zoological Park, Alexander Sudakov, Evgeniy Andrianov, Voronezh State Agrarian University named after Emperor Peter the Great, Aleksey Andrianov, Nikolai Skuratov

    It is known that the air composition in the incubator chamber is critically important for the development of bird embryos, since the embryo consumes oxygen and produces carbon dioxide during development. High embryonic mortality is observed with insufficient ventilation of the incubator chamber, however, excessive ventilation leads to unreasonable costs of electricity and water in the humidification system. Gas analyzers that allow precise regulation of gas exchange between the incubator chamber and the surrounding air are not used in tabletop incubators, and the problem of determining the optimal ventilation parameters for tabletop incubators remains relevant at present. The possibility of interpreting data on water consumption by humidification systems of tabletop incubators in order to determine the characteristics of oxygen and carbon dioxide gas exchange between the air in the incubator chamber and the environment was studied. Grumbach tabletop incubators, a carbon dioxide detector based on the ZGm053UK IR sensor, and an AT-8100 electrochemical oxygen detector were used. It was established that the dynamics of water consumption of the incubator humidification system correlates with the volume of gas exchange between the incubator and the environment. The danger of stopping the respiratory activity of embryos occurs in sealed incubators, while the marker of the absence of gas exchange is a constant water level in the humidification system. With the rate of water evaporation by the evaporator of at least 3 cm3 / day per 1 chicken egg, the difference in relative humidity in the incubator room and the incubator chamber of at least 10% and the difference in temperatures in the incubator and the incubator room of at least 10 ° C, the gas exchange of the incubator with the room provides a carbon dioxide level of no more than 3000 ppm, and an oxygen level of at least 20.6%. The air composition in the incubator room has a direct effect on the air composition in the incubator, however, the required ventilation level of the incubator room, providing satisfactory air quality, can be determined organoleptically.

  • BROODER HEATER WITH ARTIFICIAL INTELLIGENCE

    by Alexander Sudakov, Moscow State Zoological Park, Evgeniy Andrianov, Aleksey Andrianov, Nikolai Skuratov, Voronezh State Agrarian University named after Emperor Peter the Great

    It is known that ensuring optimal temperature regime of young poultry at the early stage of embryonic development is possible only in a narrow temperature range and instrumental control of temperatures when keeping young poultry under brooder lamps does not provide the necessary accuracy. According to the current recommendations of manufacturers of modern crosses of poultry, the adjustment of the brooder lamp suspension height is based on the data of visual control during which the behavior of young birds is evaluated. The possibility of automating the process of adjusting the height of the suspension of brooder lamps was investigated. A video analytics software and hardware complex based on the YOLOv2 neural network, a PyAi-k210 machine vision platform from the 01studio company based on a Kendryte k210 microcontroller, and an electric linear actuator were used. The neural network was trained on a dataset of 1000 images for each class with a resolution of 224x224 pixels. Maixhub.com cloud service was used for training. Image rotation and reflections were applied for automatic augmentation. The mobilenet_0.5 831Kb model was used. The training duration is 100 epochs. 4 electromagnetic relays were used to control the linear actuator. 2 power electromagnetic relays with two groups of contacts for switching the polarity of the linear actuator power supply and 2 electronic relay modules with galvanic isolation, which were controlled directly from the microcontroller contacts. The program code of the microcontroller, obtained during training of the model, was adjusted to form a control signal to the electronic relay modules. Programming was carried out in MicroPython language. As a result of the study, a test sample of the device was made, which registers the position of young birds in the brooder and automatically changes the height of brooder lamp suspension.