LCLe Chang

Le Chang

*This is an algorithmically generated author record based on publicly available information.

Le Chang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    UV and Visible Radiation Characteristics of Thermoacoustic Instabilities in an Ammonia–Methane Premixed Swirl-Stabilized Combustor

    by Junhui Ma, Xianglan Fu, Dongqi Chen, Le Chang, Lingxue Wang, Yingchen Shi, Haocheng Wen, Bing Wang

    Ammonia (NH3) is a promising carbon-free energy carrier for low-carbon power generation. However, in turbulent ammonia–methane (NH3-CH4) premixed swirling flames, operating at lean conditions to limit NOX, emissions can trigger strong thermoacoustic oscillations. This study investigates thermoacoustic oscillatory instability in an NH3-CH4 swirl-stabilized combustor using the chemiluminescence of CH*, OH*, and NH* over a wide range of ammonia fuel fraction (XNH3). Combined spectral measurements and 2D chemiluminescence imaging are employed to obtain the global emission characteristics and spatial distributions of OH* and NH* in the UV band and CH* in the visible band. A custom-designed intensified CMOS (ICMOS) camera based on a high-gain UV–visible image intensifier with direct coupling is developed to enable sensitive OH* and NH* imaging (gain > 104). Frequency analysis of continuous CH* imaging, together with morphology-based principal component analysis and k-means clustering of 46 image features, shows that oscillatory combustion occurs for XNH3 < 0.40, whereas XNH3 ≥ 0.40 leads to multimode, stable combustion. As XNH3 increases, OH* and NH* fields progressively decouple from CH*, becoming more elongated and shifting downstream. These results demonstrate that UV radical chemiluminescence provides indispensable information on NH3 reaction zones and should be combined with CH* diagnostics for reliable thermoacoustic analysis and control in practical NH3-fueled combustion systems.


  • Open Access

    Equivalent Mechanical Model of a Microchannel Plate

    by Shengdan Zhang, Yonglin Bai, Weiwei Cao, Junjun Qin, Jiarui Gao, Le Chang, Beihong Liu, Zexun Hu, Zhujun Chu, Xiaoqing Cong, et al.

    The microchannel plate (MCP) is an electron multiplier with millions of micro through-holes that must withstand strong vibrations and enormous shocks in spaceborne detectors. To ensure the reliability and robustness of the MCP in space applications, we proposed an equivalent mechanical model of the MCP to investigate its mechanical properties, since the direct creation of the finite element model using the finite element method (FEM) is not feasible. Then, we developed a test system to verify the effectiveness of the equivalent mechanical model. The results show that the error of harmonic response analysis and the test result is less than 10 %, which is acceptable. Finally, we conducted parametric studies of the MCPs and obtained the equivalent mechanical model of the MCPs with different geometric parameters. This study will help researchers to optimize the MCP for aerospace-grade detectors.


  • Development of afterglow time test system for nanosecond fluorescent screen of low-level-light image intensifier

    by Lu Jie, Chang Le, Chen Yixin, Jiang Yunlong, Su Tianning, Liu Beihong, Zhao Hang, Qian Yunsheng, Liu Jian, 南京理工大学电子工程与光电技术学院,江苏南京210094, et al.

    The time characteristics of fluorescent screen is one of the important parameters to evaluate the performance of image intensifier. At present, there is no measurement method for the afterglow time of nanosecond fluorescent screen of low-level-light image intensifier. Based on the traditional test scheme of image intensifier afterglow time, a afterglow time test system for nanosecond fluorescent screen was developed. This system used a high-speed signal generator with the sampling rate of 250 MHz to complete the excitation of the laser diode light pulse, and a photomultiplier tube was used with the descending time of 0.57 ns to complete the photoelectric conversion of the fluorescent screen light signal. The weak photocurrent signal of µA magnitude was amplified and converted to a single-terminal differential circuit to complete the AD conversion in AD9684. Then the digital luminance information of the fluorescent screen was stored in the double data rate SDRAM (DDR) unit after field programmable gate array (FPGA), and the host computer sent instructions to read the DDR memory. The USB3.0 high-speed transmission protocol was used to transmit data to the host computer. In the data processing, the Kalman filtering and fast finding falling edge algorithm were used to realize the accurate measurement of noise filtering from collected data and afterglow time. The test results show that the proposed afterglow time test system for nanosecond fluorescent screen can effectively test the image intensifier with ultrafast optical characteristics. The afterglow test results of P47 phosphor reaches 118. 094 4 ns, and the repeatability reaches 2.08%.