IVIlias Vandevenne

Ilias Vandevenne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ilias Vandevenne has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Signal inversion and defect selectivity in charge pumping electrically detected magnetic resonance of a 4H-SiC n-channel metal-oxide-semiconductor field-effect transistor

    by Jan Lettens, Ilias Vandevenne, Marina Avramenko, Henk Vrielinck, Etienne Goovaerts, Peter Moens, Sofie Cambré

    Charge pumping electrically detected magnetic resonance (CP-EDMR) has previously been demonstrated as a characterization technique for performance-limiting point defects in metal-oxide-semiconductor field-effect-transistors (MOSFETs). This Letter demonstrates the much-promised defect selectivity of CP-EDMR in a 4H-SiC n-channel MOSFET, differentiating between two distinct paramagnetic centers based on the kinetic properties, following from variation of the experimental CP parameters. The centers are shown to differ both in their characteristic g-shifts and in hyperfine interactions with surrounding nuclei. In addition, we show that under magnetic resonance conditions these two defects show opposite effects on the CP current, which results in a sign inversion of the CP-EDMR spectrum. For one defect, which only appears under relatively low-frequency CP-excitation, the microwaves induce a decrease in CP-current, while the other defect shows an increase at all applied CP-frequencies. Starting from an empirical CP model, we demonstrate that an enhanced efficiency of carrier capture or emission leads to either an increase or a decrease in the CP current, respectively. Simulations based on this model qualitatively reproduce the observed dependencies of the CP-EDMR signal on CP bias voltage and excitation frequency.


  • Open Access

    Integration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in silicon carbide metal–oxide–semiconductor field-effect transistors

    by Jan Lettens, Marina Avramenko, Ilias Vandevenne, Anh Chu, Philipp Hengel, Michal Kern, Jens Anders, Peter Moens, Etienne Goovaerts, Sofie Cambré

    Electrical detection of magnetic resonance (EDMR), a variant of electron paramagnetic resonance (EPR) in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices, is of high interest for studying electrically active defects in SiC metal–oxide–semiconductor field-effect transistors (MOSFETs), but requires dedicated instrumentation that is not widely available. Integration of microwave sources and detection circuits has led to the design of very compact EPR instruments, the so-called EPR-on-a-chip (EPRoC), which also offers opportunities for EDMR-on-a-chip (EDMRoC). Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC setup compared to EDMR in a conventional EPR spectrometer, offering promise for widespread integration of EDMR in semiconductor laboratories.


  • Open Access

    Integration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in SiC MOSFETs

    by Jan Lettens, Marina Avramenko, Ilias Vandevenne, Anh Chu, Philipp Hengel, Michal Kern, Jens Anders, Peter Moens, Etienne Goovaerts, Sofie Cambré

    Integration of microwave sources and detection circuits has led to the design of very compact electron paramagnetic resonance (EPR) instruments, so-called EPR on-a-chip (EPRoC). As recently demonstrated, this approach also offers opportunities for electrical detection of magnetic resonance (EDMR), a variant of EPR in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices. Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC set-up compared to EDMR in a conventional EPR spectrometer.