Ilias Vandevenne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ilias Vandevenne has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Marina V. Avramenko
Onsemi, Westerring 15, Oudenaarde, 9700, Belgium
3 shared publications - Sofie Cambré
Nanostructured and Organic Optical and Electronic Materials, Physics Department, University of Antwerp, Belgium
3 shared publications Anh Chu
Institute of Smart Sensors, Universität Stuttgart 3 , Stuttgart 70569
2 shared publications- Etienne Goovaerts
Physics Department, University of Antwerp, Belgium
2 shared publications - Jan Lettens
Theory and Spectroscopy of Molecules and Materials, Department of Physics, University of Antwerp 1 , Universiteitsplein 1, B-2610 Antwerp
2 shared publications - Michal Kern
University of Stuttgart
2 shared publications
Latest Publications
- 19 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (20)
Signal inversion and defect selectivity in charge pumping electrically detected magnetic resonance of a 4H-SiC n-channel metal-oxide-semiconductor field-effect transistor
Charge pumping electrically detected magnetic resonance (CP-EDMR) has previously been demonstrated as a characterization technique for performance-limiting point defects in metal-oxide-semiconductor field-effect-transistors (MOSFETs). This Letter demonstrates the much-promised defect selectivity of CP-EDMR in a 4H-SiC n-channel MOSFET, differentiating between two distinct paramagnetic centers based on the kinetic properties, following from variation of the experimental CP parameters. The centers are shown to differ both in their characteristic g-shifts and in hyperfine interactions with surrounding nuclei. In addition, we show that under magnetic resonance conditions these two defects show opposite effects on the CP current, which results in a sign inversion of the CP-EDMR spectrum. For one defect, which only appears under relatively low-frequency CP-excitation, the microwaves induce a decrease in CP-current, while the other defect shows an increase at all applied CP-frequencies. Starting from an empirical CP model, we demonstrate that an enhanced efficiency of carrier capture or emission leads to either an increase or a decrease in the CP current, respectively. Simulations based on this model qualitatively reproduce the observed dependencies of the CP-EDMR signal on CP bias voltage and excitation frequency.
- 19 May 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (20)
Signal inversion and defect selectivity in charge pumping electrically detected magnetic resonance of a 4H-SiC n-channel metal-oxide-semiconductor field-effect transistor
Charge pumping electrically detected magnetic resonance (CP-EDMR) has previously been demonstrated as a characterization technique for performance-limiting point defects in metal-oxide-semiconductor field-effect-transistors (MOSFETs). This Letter demonstrates the much-promised defect selectivity of CP-EDMR in a 4H-SiC n-channel MOSFET, differentiating between two distinct paramagnetic centers based on the kinetic properties, following from variation of the experimental CP parameters. The centers are shown to differ both in their characteristic g-shifts and in hyperfine interactions with surrounding nuclei. In addition, we show that under magnetic resonance conditions these two defects show opposite effects on the CP current, which results in a sign inversion of the CP-EDMR spectrum. For one defect, which only appears under relatively low-frequency CP-excitation, the microwaves induce a decrease in CP-current, while the other defect shows an increase at all applied CP-frequencies. Starting from an empirical CP model, we demonstrate that an enhanced efficiency of carrier capture or emission leads to either an increase or a decrease in the CP current, respectively. Simulations based on this model qualitatively reproduce the observed dependencies of the CP-EDMR signal on CP bias voltage and excitation frequency.
- Open Access
- 12 February 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (6)
Integration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in silicon carbide metal–oxide–semiconductor field-effect transistors
Electrical detection of magnetic resonance (EDMR), a variant of electron paramagnetic resonance (EPR) in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices, is of high interest for studying electrically active defects in SiC metal–oxide–semiconductor field-effect transistors (MOSFETs), but requires dedicated instrumentation that is not widely available. Integration of microwave sources and detection circuits has led to the design of very compact EPR instruments, the so-called EPR-on-a-chip (EPRoC), which also offers opportunities for EDMR-on-a-chip (EDMRoC). Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC setup compared to EDMR in a conventional EPR spectrometer, offering promise for widespread integration of EDMR in semiconductor laboratories.
- 12 February 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (6)
Open AccessIntegration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in silicon carbide metal–oxide–semiconductor field-effect transistors
Electrical detection of magnetic resonance (EDMR), a variant of electron paramagnetic resonance (EPR) in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices, is of high interest for studying electrically active defects in SiC metal–oxide–semiconductor field-effect transistors (MOSFETs), but requires dedicated instrumentation that is not widely available. Integration of microwave sources and detection circuits has led to the design of very compact EPR instruments, the so-called EPR-on-a-chip (EPRoC), which also offers opportunities for EDMR-on-a-chip (EDMRoC). Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC setup compared to EDMR in a conventional EPR spectrometer, offering promise for widespread integration of EDMR in semiconductor laboratories.
- Open Access
- 11 July 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-26
Integration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in SiC MOSFETs
Integration of microwave sources and detection circuits has led to the design of very compact electron paramagnetic resonance (EPR) instruments, so-called EPR on-a-chip (EPRoC). As recently demonstrated, this approach also offers opportunities for electrical detection of magnetic resonance (EDMR), a variant of EPR in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices. Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC set-up compared to EDMR in a conventional EPR spectrometer.
- 11 July 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-26
Open AccessIntegration of electrically detected magnetic resonance on a chip (EDMRoC) with charge pumping for low-cost and sensitive defect characterization in SiC MOSFETs
Integration of microwave sources and detection circuits has led to the design of very compact electron paramagnetic resonance (EPR) instruments, so-called EPR on-a-chip (EPRoC). As recently demonstrated, this approach also offers opportunities for electrical detection of magnetic resonance (EDMR), a variant of EPR in which the magnetic resonance effect is detected via changes in the electrical properties of materials or devices. Here, we report the demonstration of EDMRoC on lateral SiC MOSFETs under charge pumping (CP) conditions. The detected CP current gives direct access to microscopic information about the recombination centers within the transistor gate inversion region under the gate dielectric. Efficient and selective microwave excitation of the region of interest of the device can be obtained by only modest modifications to both the MOSFET and the EPRoC electronic board. A comparative study between EDMRoC and a traditional resonant cavity configuration reveals comparable signal-to-noise ratios for CP-detected EDMR spectra. In addition to space- and cost-efficiency, EDMRoC offers alternative detection modes with scanning and modulation of the microwave frequency, as well as potentially easier sample mounting and exchange. We end with a discussion of the advantages, limitations, and perspectives of the EDMRoC set-up compared to EDMR in a conventional EPR spectrometer.