Chuncan Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chuncan Fan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Jiqiao Liu
Wangzhijiang Innovation Center for Laser, Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, 201800, China
6 shared publicationsWeibiao Chen
Wangzhijiang Innovation Center for Laser, Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, 201800, China
6 shared publicationsJinrui Guo
State Key Laboratory of Environment Characteristics and Effects for Near-space, Nanjing University of Information Science and Technology, Nanjing, 210044, China
3 shared publicationsJiyu Wang
State Key Laboratory of Environment Characteristics and Effects for Near-space, Nanjing University of Information Science and Technology, Nanjing, 210044, China
3 shared publicationsQingting Zhu
State Key Laboratory of Environment Characteristics and Effects for Near-space, Nanjing University of Information Science and Technology, Nanjing, 210044, China
3 shared publicationsXiaopeng Zhu
University of Chinese Academy of Sciences
3 shared publications
Latest Publications
- Open Access
- 20 September 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-33
Comment on egusphere-2026-3759
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- 20 September 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-33
Open AccessComment on egusphere-2026-3759
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- Open Access
- 22 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-33
Comment on egusphere-2026-3759
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- 22 August 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-33
Open AccessComment on egusphere-2026-3759
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- Open Access
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
Random Error and Averaging Strategies for XCO 2 Observations from Spaceborne IPDA Lidar Onboard DQ-1 Satellite
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
Open AccessRandom Error and Averaging Strategies for XCO 2 Observations from Spaceborne IPDA Lidar Onboard DQ-1 Satellite
Carbon dioxide (CO2) is one of the most important anthropogenic greenhouse gases in the atmosphere, and accurate monitoring of CO2 concentration is essential for carbon flux inversion and emission reduction policies. Spaceborne integrated path differential absorption (IPDA) lidar enables day-and-night observations, high-latitude coverage, and reduced sensitivity to clouds and aerosols, showing great potential for monitoring the column-averaged dry-air mole fraction of CO2 (XCO2). However, single-shot XCO2 retrievals from spaceborne IPDA lidar generally have relatively large random errors, and their along-track averaging is affected by surface conditions and data gaps. Based on 2023 DQ-1 spaceborne IPDA lidar observations, this study calculated global single-shot XCO2 random errors using the return-signal SNRs at the online and offline wavelengths. The results show pronounced spatial heterogeneity in single-shot random errors. Larger errors occur over water bodies, permanent snow and ice, and some complex land cover types, whereas day–night differences are relatively weak. Combining MCD12C1 land cover data with random-error statistics, the global observation scenes were classified into four surface random-error categories. Allan variance analysis of continuous observation segments suggests averaging approximately 160, 200, 232, and 296 observations for the four categories, corresponding to typical along-track scales of about 54, 67, 77, and 100 km. To address data gaps and along-track discontinuities, fixed-spatial-resolution and random-error-threshold-controlled averaging strategies were compared. The fixed-spatial-resolution strategy maintains more stable spatial representativeness and is more suitable as the default averaging option, whereas the threshold-controlled strategy improves error consistency but may substantially expand the averaging window. For land–sea boundaries and other rapid surface-transition regions, a boundary mixed dynamic averaging strategy was further proposed, with surface-category fractions recommended as quality indicators. These results support random-error evaluation and averaging-strategy design for spaceborne IPDA lidar XCO2 products.
- 6 May 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (14) , 3927-3935
Performance analysis on the feasibility and accuracy of triple-wavelength integrated path absorption lidar for atmospheric CO2 measurement
This study focuses on exploring the feasibility and accuracy of triple-wavelength integrated path differential absorption (IPDA) lidar to measure the atmospheric CO2 column concentration. Traditional IPDA lidar-based two wavelengths for measuring CO2 are highly dependent on meteorological parameters such as temperature, pressure, and humidity. Multi-wavelength IPDA lidar has shown potential for overcoming these challenges. By introducing a third wavelength into the IPDA lidar, we could further reduce interference from water vapor and decrease the sensitivity to atmospheric parameters, such as temperature and pressure. Simulation results indicate that the triple-wavelength IPDA lidar can significantly reduce system errors compared to the dual-wavelength lidar. The global system error is reduced by an average error of 0.156 ppm, with a mean total error of 0.517 ppm for the triple-wavelength IPDA lidar. This study provides theoretical support for the optimization and application of future lidar systems in atmospheric CO2 monitoring.
- 6 May 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (14) , 3927-3935
Performance analysis on the feasibility and accuracy of triple-wavelength integrated path absorption lidar for atmospheric CO2 measurement
This study focuses on exploring the feasibility and accuracy of triple-wavelength integrated path differential absorption (IPDA) lidar to measure the atmospheric CO2 column concentration. Traditional IPDA lidar-based two wavelengths for measuring CO2 are highly dependent on meteorological parameters such as temperature, pressure, and humidity. Multi-wavelength IPDA lidar has shown potential for overcoming these challenges. By introducing a third wavelength into the IPDA lidar, we could further reduce interference from water vapor and decrease the sensitivity to atmospheric parameters, such as temperature and pressure. Simulation results indicate that the triple-wavelength IPDA lidar can significantly reduce system errors compared to the dual-wavelength lidar. The global system error is reduced by an average error of 0.156 ppm, with a mean total error of 0.517 ppm for the triple-wavelength IPDA lidar. This study provides theoretical support for the optimization and application of future lidar systems in atmospheric CO2 monitoring.
- 30 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (12) , 21870-21886
Preliminary analysis of global column-averaged CO2 concentration data from the spaceborne aerosol and carbon dioxide detection lidar onboard AEMS
In contrast to the passive remote sensing of global CO2 column concentrations (XCO2), active remote sensing with a lidar enables continuous XCO2 measurements throughout the entire atmosphere in daytime and nighttime. The lidar could penetrate most cirrus and is almost unaffected by aerosols. Atmospheric environment monitoring satellite (AEMS, also named DQ-1) aerosol and carbon dioxide detection Lidar (ACDL) is a novel spaceborne lidar that implements a 1572 nm integrated path differential absorption (IPDA) method to measure the global XCO2 for the first time. In this study, special methods have been developed for ACDL data processing and XCO2 retrieval. The CO2 measurement data products of ACDL, including the differential absorption optical depth between the online and offline wavelengths, the integral weighting function, and XCO2, are presented. The results of XCO2 measurements over the period from 1st June 2022 to 30th June 2022 (first month data of ACDL) are analyzed to demonstrate the measurement capabilities of the spaceborne ACDL system.
- 30 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (12) , 21870-21886
Preliminary analysis of global column-averaged CO2 concentration data from the spaceborne aerosol and carbon dioxide detection lidar onboard AEMS
In contrast to the passive remote sensing of global CO2 column concentrations (XCO2), active remote sensing with a lidar enables continuous XCO2 measurements throughout the entire atmosphere in daytime and nighttime. The lidar could penetrate most cirrus and is almost unaffected by aerosols. Atmospheric environment monitoring satellite (AEMS, also named DQ-1) aerosol and carbon dioxide detection Lidar (ACDL) is a novel spaceborne lidar that implements a 1572 nm integrated path differential absorption (IPDA) method to measure the global XCO2 for the first time. In this study, special methods have been developed for ACDL data processing and XCO2 retrieval. The CO2 measurement data products of ACDL, including the differential absorption optical depth between the online and offline wavelengths, the integral weighting function, and XCO2, are presented. The results of XCO2 measurements over the period from 1st June 2022 to 30th June 2022 (first month data of ACDL) are analyzed to demonstrate the measurement capabilities of the spaceborne ACDL system.
- 11 March 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (9) , 2121-2131
Airborne atmospheric carbon dioxide measurement using 1.5 µm laser double-pulse IPDA lidar over a desert area
An integrated path differential absorption (IPDA) lidar can accurately measure regional CO2 weighted column average concentrations (XCO2), which are crucial for understanding the carbon cycle in climate change studies. To verify the performance and data inversion methods of space-borne IPDA lidar, in July 2021, we conducted an airborne lidar validation experiment in Dunhuang, Gansu Province, China. An aircraft was equipped with a lidar system developed to measure XCO2 and an in situ greenhouse gas analyzer (GGA). To minimize measurement errors, energy monitoring was optimized. The system bias error of the DAOD was determined by changing the laser output mode from the off/on to the on/on mode. The XCO2 inversion results obtained through comparing the schemes of averaging signals before “log (logarithm)” and averaging after “log” indicate that the former performs better. The IPDA lidar measured XCO2 over the validation site at 405.57 ppm, and both the IPDA lidar and GGA measured sudden changes in the CO2concentration. The assimilation data showed a similar trend according to the altitude to the data measured by the in situ instrument. A comparison of the mean XCO2 derived from the GGA results and assimilation data with the IPDA lidar measurements showed biases of 0.80 and 1.12 ppm, respectively.
- 11 March 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (9) , 2121-2131
Airborne atmospheric carbon dioxide measurement using 1.5 µm laser double-pulse IPDA lidar over a desert area
An integrated path differential absorption (IPDA) lidar can accurately measure regional CO2 weighted column average concentrations (XCO2), which are crucial for understanding the carbon cycle in climate change studies. To verify the performance and data inversion methods of space-borne IPDA lidar, in July 2021, we conducted an airborne lidar validation experiment in Dunhuang, Gansu Province, China. An aircraft was equipped with a lidar system developed to measure XCO2 and an in situ greenhouse gas analyzer (GGA). To minimize measurement errors, energy monitoring was optimized. The system bias error of the DAOD was determined by changing the laser output mode from the off/on to the on/on mode. The XCO2 inversion results obtained through comparing the schemes of averaging signals before “log (logarithm)” and averaging after “log” indicate that the former performs better. The IPDA lidar measured XCO2 over the validation site at 405.57 ppm, and both the IPDA lidar and GGA measured sudden changes in the CO2concentration. The assimilation data showed a similar trend according to the altitude to the data measured by the in situ instrument. A comparison of the mean XCO2 derived from the GGA results and assimilation data with the IPDA lidar measurements showed biases of 0.80 and 1.12 ppm, respectively.