Mark T. Madsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mark T. Madsen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Mary Sue O'DOrisio
Department of Pediatrics, University of Iowa Carver College of Medicine, Iowa City, Iowa
3 shared publications - David L. Bushnell
Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, Iowa
2 shared publications - Thomas M. O'DOrisio
Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, IA
2 shared publications - Yusuf Menda
University of Iowa, Iowa City, Iowa
2 shared publications Andrew N. Ellingson
Department of Radiology, The University of Iowa, 200 Hawkins Drive, Iowa City, IA 52242
1 shared publication- Beth A. Harkness
Department of Radiology, Henry Ford Hospital, Detroit, Michigan; and
1 shared publication
Latest Publications
- 16 April 2018
- Published by Wiley in Medical Physics
- Vol. 45 (5) , 2318-2324
Technical Note: Single time point dose estimate for exponential clearance
Objective: Although personalized dosimetry may be desirable for radionuclide therapy treatments, the multiple time samples required to determine the total integrated activity puts a burden on patients and clinic resources. The aim of this paper is to demonstrate that when some prior knowledge is known about the tracer kinetic parameters, the total integrated activity (and thus radiation dose) can be estimated from a single time sample.Methods: Mathematical derivations have been performed to generate equations for the total integrated activity in terms of a single time sample of activity for monoexponential and biexponential clearance. Simulations were performed using both exponential models where the rate constants and associated parameters were randomly sampled from distributions with a known mean. The actual total integrated activity for each random sample was compared with the estimated total integrated activity using the mean value of the parameters. Retrospective analysis of 90Y DOTATOC data from a clinical trial provided a comparison of actual kidney dose with the estimated kidney dose using the single time point approach.Results: The optimal sampling time for the single point approach was found to be equal to the mean time of the rate constant. The simulation results for the monoexponential and biexpoential models were similar. Regressions comparing the actual and estimated total integrated activity had very high correlations (r2 > 0.95) along with acceptable standard errors of estimate, especially at the optimal sampling point. The retrospective analysis of the 90Y DOTATOC data also yielded similar results with an r2 = 0.95 and a standard error of estimate of 61 cGy.Conclusions: In situations where there is prior knowledge about the population averages of kinetic parameters, these results suggest that the single time point approach can be used to estimate the total integrated activity and dose with sufficient accuracy to manage radionuclide therapy. This will make personalized dosimetry much easier to perform and more available to the community.
- 16 April 2018
- Published by Wiley in Medical Physics
- Vol. 45 (5) , 2318-2324
Technical Note: Single time point dose estimate for exponential clearance
Objective: Although personalized dosimetry may be desirable for radionuclide therapy treatments, the multiple time samples required to determine the total integrated activity puts a burden on patients and clinic resources. The aim of this paper is to demonstrate that when some prior knowledge is known about the tracer kinetic parameters, the total integrated activity (and thus radiation dose) can be estimated from a single time sample.Methods: Mathematical derivations have been performed to generate equations for the total integrated activity in terms of a single time sample of activity for monoexponential and biexponential clearance. Simulations were performed using both exponential models where the rate constants and associated parameters were randomly sampled from distributions with a known mean. The actual total integrated activity for each random sample was compared with the estimated total integrated activity using the mean value of the parameters. Retrospective analysis of 90Y DOTATOC data from a clinical trial provided a comparison of actual kidney dose with the estimated kidney dose using the single time point approach.Results: The optimal sampling time for the single point approach was found to be equal to the mean time of the rate constant. The simulation results for the monoexponential and biexpoential models were similar. Regressions comparing the actual and estimated total integrated activity had very high correlations (r2 > 0.95) along with acceptable standard errors of estimate, especially at the optimal sampling point. The retrospective analysis of the 90Y DOTATOC data also yielded similar results with an r2 = 0.95 and a standard error of estimate of 61 cGy.Conclusions: In situations where there is prior knowledge about the population averages of kinetic parameters, these results suggest that the single time point approach can be used to estimate the total integrated activity and dose with sufficient accuracy to manage radionuclide therapy. This will make personalized dosimetry much easier to perform and more available to the community.
- Open Access
- 10 September 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 1-8
Feasibility and advantage of adding 131I-MIBG to 90Y-DOTATOC for treatment of patients with advanced stage neuroendocrine tumors
Peptide receptor radionuclide therapy (PRRT) is an effective form of treatment for patients with metastatic neuroendocrine tumors (NETs). However, delivering sufficient radiation dose to the tumor to result in a high percentage of long-term tumor remissions remains challenging because of the limits imposed on administered activity levels by radiation damage to normal tissues. The goal of this study was to evaluate the dosimetric advantages of adding 131I meta-iodobenzylguanidine (131I-MIBG) to 90Y DOTA Phe1-Tyr3-octreotide (90Y-DOTATOC) in patients with advanced stage midgut NETs. Ten patients were imaged simultaneously with 131I-MIBG and 111In-pentetreotide (as a surrogate for 90Y-DOTATOC) on days 1, 2, and 3 post-administration. Blood samples were obtained at the same time points. Using dosimetry measures from this data and our previously published methodology for calculating optimal combined administered activity levels for therapy, we determined the amount of 131I-MIBG that could be added to 90Y-DOTATOC without exceeding normal organ dose limits (marrow and kidneys) along with the expected increase in associated tumor dose, if any. We found that a median value of 34.6 GBq of 131I-MIBG could be safely added to 90Y-DOTATOC (delivered over multiple cycles) by reducing the maximum total deliverable 90Y-DOTATOC by a median value of 24.5%. Taking this treatment approach, we found that there would be a median increase in deliverable tumor dose of 4,046 cGy in six of the ten subjects. Of note, there were a small number of metastases that were positive for only one or the other of these radiopharmaceuticals within the same subject. We conclude that approximately half of the patients with midgut NETs that are eligible for PRRT could reasonably be expected to benefit from the addition of 131I-MIBG to 90Y-DOTATOC.
- 10 September 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 1-8
Open AccessFeasibility and advantage of adding 131I-MIBG to 90Y-DOTATOC for treatment of patients with advanced stage neuroendocrine tumors
Peptide receptor radionuclide therapy (PRRT) is an effective form of treatment for patients with metastatic neuroendocrine tumors (NETs). However, delivering sufficient radiation dose to the tumor to result in a high percentage of long-term tumor remissions remains challenging because of the limits imposed on administered activity levels by radiation damage to normal tissues. The goal of this study was to evaluate the dosimetric advantages of adding 131I meta-iodobenzylguanidine (131I-MIBG) to 90Y DOTA Phe1-Tyr3-octreotide (90Y-DOTATOC) in patients with advanced stage midgut NETs. Ten patients were imaged simultaneously with 131I-MIBG and 111In-pentetreotide (as a surrogate for 90Y-DOTATOC) on days 1, 2, and 3 post-administration. Blood samples were obtained at the same time points. Using dosimetry measures from this data and our previously published methodology for calculating optimal combined administered activity levels for therapy, we determined the amount of 131I-MIBG that could be added to 90Y-DOTATOC without exceeding normal organ dose limits (marrow and kidneys) along with the expected increase in associated tumor dose, if any. We found that a median value of 34.6 GBq of 131I-MIBG could be safely added to 90Y-DOTATOC (delivered over multiple cycles) by reducing the maximum total deliverable 90Y-DOTATOC by a median value of 24.5%. Taking this treatment approach, we found that there would be a median increase in deliverable tumor dose of 4,046 cGy in six of the ten subjects. Of note, there were a small number of metastases that were positive for only one or the other of these radiopharmaceuticals within the same subject. We conclude that approximately half of the patients with midgut NETs that are eligible for PRRT could reasonably be expected to benefit from the addition of 131I-MIBG to 90Y-DOTATOC.
- Open Access
- 1 April 2007
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 48 (4) , 661-673
Recent Advances in SPECT Imaging
SPECT is a rapidly changing field, and the past several years have produced new developments in both hardware technology and image-processing algorithms. At the component level there have been improvements in scintillators and photon transducers as well as a greater availability of semiconductor technology. These devices permit the fabrication of smaller and more compact systems that can be customized for particular applications. New clinical devices include high-count sensitivity cardiac SPECT systems that do not use conventional collimation and the introduction of diagnostic-quality hybrid SPECT/CT systems. While there has been steady progress with reconstruction algorithms, exciting new processing algorithms have become commercially available that promise to provide substantial reductions in SPECT acquisition time without sacrificing diagnostic quality. Preclinical small-animal SPECT systems have become a major focus in nuclear medicine. These systems have pushed the limits of SPECT into the submillimeter range, making them valuable molecular imaging tools capable of providing information unavailable from other modalities.
- 1 April 2007
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 48 (4) , 661-673
Open AccessRecent Advances in SPECT Imaging
SPECT is a rapidly changing field, and the past several years have produced new developments in both hardware technology and image-processing algorithms. At the component level there have been improvements in scintillators and photon transducers as well as a greater availability of semiconductor technology. These devices permit the fabrication of smaller and more compact systems that can be customized for particular applications. New clinical devices include high-count sensitivity cardiac SPECT systems that do not use conventional collimation and the introduction of diagnostic-quality hybrid SPECT/CT systems. While there has been steady progress with reconstruction algorithms, exciting new processing algorithms have become commercially available that promise to provide substantial reductions in SPECT acquisition time without sacrificing diagnostic quality. Preclinical small-animal SPECT systems have become a major focus in nuclear medicine. These systems have pushed the limits of SPECT into the submillimeter range, making them valuable molecular imaging tools capable of providing information unavailable from other modalities.
- 1 April 2007
- Published by Elsevier in Academic Radiology
- Vol. 14 (4) , 495-504
A Segmentation-Based Method for Metal Artifact Reduction
- 1 April 2007
- Published by Elsevier in Academic Radiology
- Vol. 14 (4) , 495-504
A Segmentation-Based Method for Metal Artifact Reduction
- 1 April 2006
- Vol. 47 (4) , 660-7
Potential increased tumor-dose delivery with combined 131I-MIBG and 90Y-DOTATOC treatment in neuroendocrine tumors: a theoretic model.
(131)I-Metaiodobenzylguanidine (MIBG) and (90)Y-DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) have been used as radiotherapeutic agents for treating neuroendocrine tumors. The tumor dose delivered by these agents is often insufficient to control or cure the disease. However, these 2 agents used together could potentially increase tumor dose without exceeding the critical organ dose because the dose-limiting tissues are different. In this paper, we investigate the conditions in which combined-agent therapy is advantageous and we quantify the expected tumor-dose gain. A series of equations was derived that predicted the optimal combination of agents and the fractional increase in tumor dose available from combined-agent therapy with respect to either (131)I-MIBG or (90)Y-DOTATOC. The results obtained from these derivations were compared with direct dose calculations using published dosimetric organ values for (131)I-MIBG and (90)Y-DOTATOC along with critical organ-dose limits. Tumor dose was calculated as a function of the tumor-dose ratio, defined as the (90)Y-DOTATOC tumor dose per megabecquerel divided by the (131)I-MIBG tumor dose per megabecquerel. Comparisons were made between the dose delivered to tumor with single-agent therapy and the dose delivered to tumor with combined-agent therapy as a function of the tumor-dose ratio and the fraction of activity contributed by each agent. The dose model accurately predicted the optimal combination of agents, the range at which combined-agent therapy was advantageous, and the magnitude of the increase. For the published organ dosimetry and critical organ-dose limits, combined-agent therapy increased tumor dose when the tumor-dose ratio was greater than 0.67 and less than 5.93. The maximum combined-agent tumor-dose increase of 68% occurred for a tumor-dose ratio of 2.57, using 92% of the maximum tolerated (90)Y-DOTATOC activity supplemented with 76% of the maximum tolerated activity of (131)I-MIBG. Variations in organ dose per megabecquerel and dose-limiting values altered both the magnitude of the increase and the range at which combined-agent therapy was advantageous. Combining (131)I-MIBG and (90)Y-DOTATOC for radiotherapy of neuroendocrine tumors can significantly increase the delivered tumor dose over the dose obtained from using either agent alone. Prior knowledge of the normal-organ and tumor dosimetry of both agents is required to determine the magnitude of the increase.
- 1 April 2006
- Vol. 47 (4) , 660-7
Potential increased tumor-dose delivery with combined 131I-MIBG and 90Y-DOTATOC treatment in neuroendocrine tumors: a theoretic model.
(131)I-Metaiodobenzylguanidine (MIBG) and (90)Y-DOTA-D-Phe1-Tyr3-octreotide (DOTATOC) have been used as radiotherapeutic agents for treating neuroendocrine tumors. The tumor dose delivered by these agents is often insufficient to control or cure the disease. However, these 2 agents used together could potentially increase tumor dose without exceeding the critical organ dose because the dose-limiting tissues are different. In this paper, we investigate the conditions in which combined-agent therapy is advantageous and we quantify the expected tumor-dose gain. A series of equations was derived that predicted the optimal combination of agents and the fractional increase in tumor dose available from combined-agent therapy with respect to either (131)I-MIBG or (90)Y-DOTATOC. The results obtained from these derivations were compared with direct dose calculations using published dosimetric organ values for (131)I-MIBG and (90)Y-DOTATOC along with critical organ-dose limits. Tumor dose was calculated as a function of the tumor-dose ratio, defined as the (90)Y-DOTATOC tumor dose per megabecquerel divided by the (131)I-MIBG tumor dose per megabecquerel. Comparisons were made between the dose delivered to tumor with single-agent therapy and the dose delivered to tumor with combined-agent therapy as a function of the tumor-dose ratio and the fraction of activity contributed by each agent. The dose model accurately predicted the optimal combination of agents, the range at which combined-agent therapy was advantageous, and the magnitude of the increase. For the published organ dosimetry and critical organ-dose limits, combined-agent therapy increased tumor dose when the tumor-dose ratio was greater than 0.67 and less than 5.93. The maximum combined-agent tumor-dose increase of 68% occurred for a tumor-dose ratio of 2.57, using 92% of the maximum tolerated (90)Y-DOTATOC activity supplemented with 76% of the maximum tolerated activity of (131)I-MIBG. Variations in organ dose per megabecquerel and dose-limiting values altered both the magnitude of the increase and the range at which combined-agent therapy was advantageous. Combining (131)I-MIBG and (90)Y-DOTATOC for radiotherapy of neuroendocrine tumors can significantly increase the delivered tumor dose over the dose obtained from using either agent alone. Prior knowledge of the normal-organ and tumor dosimetry of both agents is required to determine the magnitude of the increase.
- 31 March 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (3) , 305-312
A New Software Tool for Removing, Storing, and Adding Abnormalities to Medical Images for Perception Research Studies
- 31 March 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (3) , 305-312
A New Software Tool for Removing, Storing, and Adding Abnormalities to Medical Images for Perception Research Studies
- 31 May 2004
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 1 (5) , 356-358
Selecting a new PET/CT system
- 31 May 2004
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 1 (5) , 356-358
Selecting a new PET/CT system
- 12 October 2000
- Vol. 37 (4) , 383-7
A device for applying static loads to prosthetic limbs of transtibial amputees during spiral CT examination.
This paper describes a device that allows the imaging of prosthetic legs under load conditions using spiral computerized tomography (CT). The device consists of a chair and a vertical footplate mounted on a 17.8 x 1.9 cm oak board that is 197 cm long. The load device can be easily positioned onto the CT bed. A subject sits in the chair and applies force by pushing the foot portion of the prosthesis against the footplate. The magnitude of the force is monitored by a digital force gauge coupled to the footplate. Because the load is borne by the hips and lower back of the subject against the chair, substantial forces can be generated and steadily maintained for the 20-45 s duration of the CT study. This device has been used successfully with 19 transtibial amputees, allowing the acquisition of spiral CT studies with half and full body weight loads.
- 12 October 2000
- Vol. 37 (4) , 383-7
A device for applying static loads to prosthetic limbs of transtibial amputees during spiral CT examination.
This paper describes a device that allows the imaging of prosthetic legs under load conditions using spiral computerized tomography (CT). The device consists of a chair and a vertical footplate mounted on a 17.8 x 1.9 cm oak board that is 197 cm long. The load device can be easily positioned onto the CT bed. A subject sits in the chair and applies force by pushing the foot portion of the prosthesis against the footplate. The magnitude of the force is monitored by a digital force gauge coupled to the footplate. Because the load is borne by the hips and lower back of the subject against the chair, substantial forces can be generated and steadily maintained for the 20-45 s duration of the CT study. This device has been used successfully with 19 transtibial amputees, allowing the acquisition of spiral CT studies with half and full body weight loads.
- 28 October 1998
- Published by Wiley in Medical Physics
- Vol. 25 (11) , 2116-2118
Proposition: Positron imaging with SPECT and dual-head scintillation cameras obviates the need for PET in oncologic imaging
- 28 October 1998
- Published by Wiley in Medical Physics
- Vol. 25 (11) , 2116-2118
Proposition: Positron imaging with SPECT and dual-head scintillation cameras obviates the need for PET in oncologic imaging