Lourdes Mendoza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lourdes Mendoza has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Lehua Zhang
College of Resource and Environmental Engineering, East China University of Science and Technology. P.O. Box 379, Nr. 130, Rd. Meilong, Shanghai 200237, China
2 shared publications - Marta Carballa
CRETUS, Department of Chemical Engineering, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain
2 shared publications - Willy Verstraete
Laboratory of Microbial Ecology and Technology (LabMET), Ghent University, Coupure Links 653, 9000 Ghent, Belgium
2 shared publications Bernardo Mora
Escuela Superior Politécnica del Litoral, ESPOL, Environmental and Chemical Sciences Department (DCQA), Faculty of Natural Science and Mathematics (FCNM), ESPOL Polytechnic University, Guayaquil, Ecuador
1 shared publicationHaci Baykara
Facultad de Ingeniería Mecánica y Ciencias de la Producción, Escuela Superior Politécnica del Litora, ESPOL, Guayaquil, Ecuador
1 shared publicationJose Delgado
Escuela Superior Politécnica del Litoral, ESPOL, Environmental and Chemical Sciences Department (DCQA), Faculty of Natural Science and Mathematics (FCNM), ESPOL Polytechnic University, Guayaquil, Ecuador
1 shared publication
Latest Publications
- 9 July 2024
- Published by Elsevier in Bioresource Technology
- Vol. 407, 131080
Perspectives on carboxylates generation from Ecuadorian agro-wastes
- 9 July 2024
- Published by Elsevier in Bioresource Technology
- Vol. 407, 131080
Perspectives on carboxylates generation from Ecuadorian agro-wastes
- 2 September 2023
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 58 (13) , 2286-2297
The potential of a natural Ecuadorian mordenite-type zeolite for batch and column selenium removal
- 2 September 2023
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 58 (13) , 2286-2297
The potential of a natural Ecuadorian mordenite-type zeolite for batch and column selenium removal
- 27 June 2009
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 160 (6) , 1822-1832
Treatment of Sanitary Landfill Leachates in a Lab-Scale Gradual Concentric Chamber (GCC) Reactor
Sanitary landfill leachates are a major environmental problem in South American countries where sanitary landfills are still constructed and appropriate designs for the treatment of these leachates remain problematic. The performance of a lab-scale Gradual Concentric Chamber (GCC) reactor for leachates treatment is presented in this study. Two types of sanitary landfill residuals were evaluated, one directly collected from the garbage trucks (JGL), with high organic strength (84 g COD/l) and the second one, a 6-month-generated leachate (YL) collected from the lagoon of the sanitary landfill in Quito, Ecuador, with an organic strength of 66 g COD/l. Different operational parameters, such as organic loading rate (OLR), temperature, recycling and aeration, were tested. The GCC reactor was found to be a robust technology to treat these high-strength streams with organic matter removal efficiencies higher than 65%. The best performance of the reactors (COD removal efficiencies of 75–80%) was obtained at a Hydraulic Retention Time (HRT) of around 20 h and at 35 °C, with an applied OLR up to 70 and 100 g COD/l per day. Overall, the GCC reactor concept appears worth to be further developed for the treatment of leachates in low-income countries.
- 27 June 2009
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 160 (6) , 1822-1832
Treatment of Sanitary Landfill Leachates in a Lab-Scale Gradual Concentric Chamber (GCC) Reactor
Sanitary landfill leachates are a major environmental problem in South American countries where sanitary landfills are still constructed and appropriate designs for the treatment of these leachates remain problematic. The performance of a lab-scale Gradual Concentric Chamber (GCC) reactor for leachates treatment is presented in this study. Two types of sanitary landfill residuals were evaluated, one directly collected from the garbage trucks (JGL), with high organic strength (84 g COD/l) and the second one, a 6-month-generated leachate (YL) collected from the lagoon of the sanitary landfill in Quito, Ecuador, with an organic strength of 66 g COD/l. Different operational parameters, such as organic loading rate (OLR), temperature, recycling and aeration, were tested. The GCC reactor was found to be a robust technology to treat these high-strength streams with organic matter removal efficiencies higher than 65%. The best performance of the reactors (COD removal efficiencies of 75–80%) was obtained at a Hydraulic Retention Time (HRT) of around 20 h and at 35 °C, with an applied OLR up to 70 and 100 g COD/l per day. Overall, the GCC reactor concept appears worth to be further developed for the treatment of leachates in low-income countries.
- 1 April 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (8) , 1155-1160
Treatment of low and medium strength sewage in a lab-scale gradual concentric chambers (GCC) reactor
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.
- 1 April 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (8) , 1155-1160
Treatment of low and medium strength sewage in a lab-scale gradual concentric chambers (GCC) reactor
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.
- 1 March 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (6) , 915-919
Inhibition of sulfide generation by dosing formaldehyde and its derivatives in sewage under anaerobic conditions
Hydrogen sulfide emission in sewers is associated with toxicity, corrosion, odor nuisance and a lot of costs. The possibility to inhibit sulfide generation by formaldehyde and its derivatives (paraformaldehyde and urea formaldehyde) has been evaluated under anaerobic conditions. The impact of formaldehyde on an activated sludge system and an appraisal of the economic aspects are also presented. The optimum dosage to inhibit sulfide generation in sewage was 12–19 mg L−1 formaldehyde. The dosages of 32 mg L−1 paraformaldehyde or 100 mg L−1 urea formaldehyde were not capable of inhibiting sulfide generation in sewage. The impact of 19 mg L−1 formaldehyde on activated sludge system was negligible in terms of COD removal, nitrification rate and oxygen uptake rate.
- 1 March 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (6) , 915-919
Inhibition of sulfide generation by dosing formaldehyde and its derivatives in sewage under anaerobic conditions
Hydrogen sulfide emission in sewers is associated with toxicity, corrosion, odor nuisance and a lot of costs. The possibility to inhibit sulfide generation by formaldehyde and its derivatives (paraformaldehyde and urea formaldehyde) has been evaluated under anaerobic conditions. The impact of formaldehyde on an activated sludge system and an appraisal of the economic aspects are also presented. The optimum dosage to inhibit sulfide generation in sewage was 12–19 mg L−1 formaldehyde. The dosages of 32 mg L−1 paraformaldehyde or 100 mg L−1 urea formaldehyde were not capable of inhibiting sulfide generation in sewage. The impact of 19 mg L−1 formaldehyde on activated sludge system was negligible in terms of COD removal, nitrification rate and oxygen uptake rate.