Sébastien Daligault
Research Subjects
Sébastien Daligault has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Denis Schwartz
Lyon Neuroscience Research Center, CRNL, INSERM U1028, CNRS UMR5292, Lyon, France
5 shared publications - Mathilde Bonnefond
Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
4 shared publications - Aymeric Guillot
Université Lyon 1, Université Jean Monnet, Univ. Savoie Mont Blanc, LIBM, EA 7424, Lyon, France
3 shared publications - Julien Jung
Department of Functional Neurology and Epileptology Hospices Civils de Lyon (Lyon University Hospital), Hospital for Neurology and Neurosurgery Pierre Wertheimer Lyon France
3 shared publications - Jérémie Mattout
Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
3 shared publications - Maxime Ferez
Université Claude Bernard Lyon 1, Université de Lyon, Lyon, France
3 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Elsevier in NeuroImage
- Vol. 343
Temporal coupling shapes the effects of prolonged muscle-tendon vibration on sensorimotor EEG activity during motor imagery
- 5 November 2026
- Published by Elsevier in NeuroImage
- Vol. 343
Open AccessTemporal coupling shapes the effects of prolonged muscle-tendon vibration on sensorimotor EEG activity during motor imagery
- Open Access
- 30 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 10128
Multilayer MEG source modelling enables depth-resolved laminar inference in humans
Neural dynamics at the laminar level are critical for cortical computation. However, in humans, non-invasive methods to probe such dynamics have been limited to coarse distinctions between deep and superficial layers. Here, we present a multilayer magnetoencephalography source reconstruction framework and evaluate the conditions under which depth-resolved laminar inference may be feasible. Using simulations, we systematically assess the limits of magnetoencephalography depth resolution, showing that laminar discrimination depends on sufficiently high signal-to-noise ratio, precise co-registration, and accurate specification of cortical column orientation. We demonstrate that regional variations in cortical anatomy influence reconstruction fidelity, with lead-field separability emerging as a key determinant. We then apply this framework to empirical data from three independent datasets and find laminar activation patterns that align with canonical feedforward and feedback motifs in visual and sensorimotor circuits, supporting the plausibility of laminar inference under favorable conditions and offering opportunities to bridge invasive electrophysiology and human neuroimaging.
- 30 September 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 10128
Open AccessMultilayer MEG source modelling enables depth-resolved laminar inference in humans
Neural dynamics at the laminar level are critical for cortical computation. However, in humans, non-invasive methods to probe such dynamics have been limited to coarse distinctions between deep and superficial layers. Here, we present a multilayer magnetoencephalography source reconstruction framework and evaluate the conditions under which depth-resolved laminar inference may be feasible. Using simulations, we systematically assess the limits of magnetoencephalography depth resolution, showing that laminar discrimination depends on sufficiently high signal-to-noise ratio, precise co-registration, and accurate specification of cortical column orientation. We demonstrate that regional variations in cortical anatomy influence reconstruction fidelity, with lead-field separability emerging as a key determinant. We then apply this framework to empirical data from three independent datasets and find laminar activation patterns that align with canonical feedforward and feedback motifs in visual and sensorimotor circuits, supporting the plausibility of laminar inference under favorable conditions and offering opportunities to bridge invasive electrophysiology and human neuroimaging.
- Open Access
- 10 August 2026
- Published by Elsevier in SSRN Electronic Journal
SMA Beta Bursts Reveal Distinct Mechanisms of Anticipatory Motor Control in Children
Anticipatory postural adjustments (APA) counteract predicted postural disturbances, emerge early in life, and undergo prolonged maturation, yet their neural mechanisms remain poorly understood. Using magnetoencephalography during a naturalistic bimanual load-lifting task, we studied anticipatory postural control in children aged 7-12. Lifting a load from the contralateral forearm induces upward elbow rotation, anticipatorily counteracted by inhibition of Biceps brachii. Despite greater variability and less efficient stabilization in children, inhibition relied on the same mechanism described in adults: transient beta bursts (19-24Hz), linked to reduced supplementary motor area (SMA) excitability, indexed by high-gamma suppression, and preceded by prefrontal and premotor influences. However, children showed lower burst frequency and additionally recruited higher-frequency bursts (24-29Hz) associated with delayed, alpha-mediated SMA suppression that attenuated post-inhibition instability. These findings demonstrate that middle-childhood children already engage adult-like APA mechanisms, but also compensate for predicted postural imprecision, offering insight into APA maturation and its alteration in neurodevelopmental conditions.
- 10 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSMA Beta Bursts Reveal Distinct Mechanisms of Anticipatory Motor Control in Children
Anticipatory postural adjustments (APA) counteract predicted postural disturbances, emerge early in life, and undergo prolonged maturation, yet their neural mechanisms remain poorly understood. Using magnetoencephalography during a naturalistic bimanual load-lifting task, we studied anticipatory postural control in children aged 7-12. Lifting a load from the contralateral forearm induces upward elbow rotation, anticipatorily counteracted by inhibition of Biceps brachii. Despite greater variability and less efficient stabilization in children, inhibition relied on the same mechanism described in adults: transient beta bursts (19-24Hz), linked to reduced supplementary motor area (SMA) excitability, indexed by high-gamma suppression, and preceded by prefrontal and premotor influences. However, children showed lower burst frequency and additionally recruited higher-frequency bursts (24-29Hz) associated with delayed, alpha-mediated SMA suppression that attenuated post-inhibition instability. These findings demonstrate that middle-childhood children already engage adult-like APA mechanisms, but also compensate for predicted postural imprecision, offering insight into APA maturation and its alteration in neurodevelopmental conditions.
- Open Access
Dynamic and task-dependent decoding of the human attentional spotlight from MEG
Attention is a fundamental mechanism enabling the brain to overcome its limited capacity for parallel processing. In non-human primates, invasive electrophysiology has shown that attentional selection operates rhythmically, primarily within the alpha (∼8–12 Hz) and theta (∼4–5 Hz) bands. Whether such finely resolved control signals can be captured non-invasively in humans, and how they adapt to changing task demands, remains unclear. Using high-precision magnetoencephalography (MEG) combined with machine learning, we decoded the spatial locus of covert attention in humans performing three variants of a spatial cueing task that manipulated cue validity as well invalid trial switching rules. Spatial attention could be decoded from whole-brain MEG activity at both static and time-resolved scales, with accuracies significantly above chance (N = 30). Decoding performance decreased as cue validity was reduced, indicating that task structure shapes attentional engagement. Analysis of decoding trajectories revealed rhythmic fluctuations at ∼8–12 Hz across all tasks, demonstrating alpha-band sampling of attention. Pre-target attention became increasingly focused on the cued side, especially in the 100% Valid condition, consistent with proactive orienting. Furthermore, individual and task-specific differences in decoding strength correlated with task-variations in behavioral performance, linking the accuracy of neural attention codes to both discrimination accuracy and reaction time. These findings demonstrate that MEG can non-invasively capture dynamic, task-dependent fluctuations in spatial attention that parallel those observed in non-human primates. They reveal that attentional demands reshape the neural code for attention, modulate rhythmic sampling, and influence behavioral efficiency. This work bridges invasive primate and non-invasive human research and establishes MEG-based decoding of attention as a promising tool for mechanistic and clinical applications, including neurofeedback and attention-related interventions.
Open AccessDynamic and task-dependent decoding of the human attentional spotlight from MEG
Attention is a fundamental mechanism enabling the brain to overcome its limited capacity for parallel processing. In non-human primates, invasive electrophysiology has shown that attentional selection operates rhythmically, primarily within the alpha (∼8–12 Hz) and theta (∼4–5 Hz) bands. Whether such finely resolved control signals can be captured non-invasively in humans, and how they adapt to changing task demands, remains unclear. Using high-precision magnetoencephalography (MEG) combined with machine learning, we decoded the spatial locus of covert attention in humans performing three variants of a spatial cueing task that manipulated cue validity as well invalid trial switching rules. Spatial attention could be decoded from whole-brain MEG activity at both static and time-resolved scales, with accuracies significantly above chance (N = 30). Decoding performance decreased as cue validity was reduced, indicating that task structure shapes attentional engagement. Analysis of decoding trajectories revealed rhythmic fluctuations at ∼8–12 Hz across all tasks, demonstrating alpha-band sampling of attention. Pre-target attention became increasingly focused on the cued side, especially in the 100% Valid condition, consistent with proactive orienting. Furthermore, individual and task-specific differences in decoding strength correlated with task-variations in behavioral performance, linking the accuracy of neural attention codes to both discrimination accuracy and reaction time. These findings demonstrate that MEG can non-invasively capture dynamic, task-dependent fluctuations in spatial attention that parallel those observed in non-human primates. They reveal that attentional demands reshape the neural code for attention, modulate rhythmic sampling, and influence behavioral efficiency. This work bridges invasive primate and non-invasive human research and establishes MEG-based decoding of attention as a promising tool for mechanistic and clinical applications, including neurofeedback and attention-related interventions.
- Open Access
Multilayer MEG source modelling enables depth-resolved laminar inference in humans
Neural dynamics at the laminar level are critical for cortical computation. However, in humans, non-invasive methods to probe such dynamics have been limited to coarse distinctions between deep and superficial layers. Here, we present a multilayer magnetoencephalography source reconstruction framework and evaluate the conditions under which depth-resolved laminar inference may be feasible. Using simulations, we systematically assess the limits of magnetoencephalography depth resolution, showing that laminar discrimination depends on sufficiently high signal-to-noise ratio, precise co-registration, and accurate specification of cortical column orientation. We demonstrate that regional variations in cortical anatomy influence reconstruction fidelity, with lead-field separability emerging as a key determinant. We then apply this framework to empirical data from three independent datasets and find laminar activation patterns that align with canonical feedforward and feedback motifs in visual and sensorimotor circuits, supporting the plausibility of laminar inference under favorable conditions and offering opportunities to bridge invasive electrophysiology and human neuroimaging.
Open AccessMultilayer MEG source modelling enables depth-resolved laminar inference in humans
Neural dynamics at the laminar level are critical for cortical computation. However, in humans, non-invasive methods to probe such dynamics have been limited to coarse distinctions between deep and superficial layers. Here, we present a multilayer magnetoencephalography source reconstruction framework and evaluate the conditions under which depth-resolved laminar inference may be feasible. Using simulations, we systematically assess the limits of magnetoencephalography depth resolution, showing that laminar discrimination depends on sufficiently high signal-to-noise ratio, precise co-registration, and accurate specification of cortical column orientation. We demonstrate that regional variations in cortical anatomy influence reconstruction fidelity, with lead-field separability emerging as a key determinant. We then apply this framework to empirical data from three independent datasets and find laminar activation patterns that align with canonical feedforward and feedback motifs in visual and sensorimotor circuits, supporting the plausibility of laminar inference under favorable conditions and offering opportunities to bridge invasive electrophysiology and human neuroimaging.
- Open Access
Unleashing the Potential of 4 He OPM-MEG: A Comparison with SQUID-MEG for Detecting Interictal Epileptic Activity
Summary: Objectives: Conventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs), are the only widely used MEG systems in both clinical and research settings. However, they have limitations that hinder their widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion-tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5-sensors MEG system with helium OPMs ( 4 He-OPMs) in detecting IEDs. Methods: First, we compare the performance of SQUID-MEG and 4 He-OPM-MEG in a routine clinical setup with a group of 7 patients. Second, we perform combined intra-cerebral (SEEG) 4 He-OPM-MEG and SQUID-MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures. Results: The key finding is that, even with a very limited number of sensors, the 4 He-OPM-MEG prototype successfully captured interictal epileptic activity in most patients. This activity was clearly detectable and exhibited the characteristic morphology with strikingly similar time courses between 4 He-OPM-MEG and SQUID-MEG signals. Using combined SEEG and OPM-MEG recordings, we obtained the first direct validation of the ability of 4 He OPM sensors to record epileptic activities originating from deep structures. Significance: These results strongly support the clinical adoption of a lightweight, high-sensitivity, whole-head 4 He OPMs-MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summary: Magnetoencephalography is a non-invasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases, as well as for fundamental neuroscience. Key points: Epileptic abnormalities are detected by 4 He OPMs as well as with classical magnetoencephalography. Hippocampal interictal activity can be detected by 4 He OPMs as shown by simultaeous SEEG-OPM recordings. This results represents significant step towards the validation of OPM-MEG for epilepsy diagnosis and neuroscience research.
Open AccessUnleashing the Potential of 4 He OPM-MEG: A Comparison with SQUID-MEG for Detecting Interictal Epileptic Activity
Summary: Objectives: Conventional magnetoencephalography (MEG) based on superconducting quantum interference devices sensors (SQUIDs), are the only widely used MEG systems in both clinical and research settings. However, they have limitations that hinder their widespread deployment. Optically pumped magnetometers (OPMs) offer several advantages over SQUIDs, particularly for epilepsy studies: lightweight and flexible, OPMs can be integrated into adaptable motion-tolerant headsets, enabling recordings during seizures or natural head movements, and potentially enhancing the detection of interictal epileptiform discharges (IEDs). In the present study, we assess the capabilities of a 5-sensors MEG system with helium OPMs ( 4 He-OPMs) in detecting IEDs. Methods: First, we compare the performance of SQUID-MEG and 4 He-OPM-MEG in a routine clinical setup with a group of 7 patients. Second, we perform combined intra-cerebral (SEEG) 4 He-OPM-MEG and SQUID-MEG recordings in a single patient to demonstrate the ability of both systems to detect IEDs originating from deep brain structures. Results: The key finding is that, even with a very limited number of sensors, the 4 He-OPM-MEG prototype successfully captured interictal epileptic activity in most patients. This activity was clearly detectable and exhibited the characteristic morphology with strikingly similar time courses between 4 He-OPM-MEG and SQUID-MEG signals. Using combined SEEG and OPM-MEG recordings, we obtained the first direct validation of the ability of 4 He OPM sensors to record epileptic activities originating from deep structures. Significance: These results strongly support the clinical adoption of a lightweight, high-sensitivity, whole-head 4 He OPMs-MEG system, offering new perspectives for epilepsy diagnostics and beyond, and enabling the democratization and spread of MEG in clinical and research settings. Plain language summary: Magnetoencephalography is a non-invasive neuroimaging technique that has been shown to improve surgical outcomes in epileptic patients. However, its use remains limited due to several constraints, which could be overcome by a new generation of sensors: the optically pumped magnetometers (OPMs). Here, we validate the ability of OPM sensors to record epileptic brain activity in a regular clinical setup and thanks to simultaneous intracerebral recordings. These sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases, as well as for fundamental neuroscience. Key points: Epileptic abnormalities are detected by 4 He OPMs as well as with classical magnetoencephalography. Hippocampal interictal activity can be detected by 4 He OPMs as shown by simultaeous SEEG-OPM recordings. This results represents significant step towards the validation of OPM-MEG for epilepsy diagnosis and neuroscience research.
- Open Access
- 20 July 2024
- Published by Elsevier in NeuroImage
- Vol. 297, 120746
Low-frequency sounds combined with motor imagery elicits a transient disruption of force performance: A path to neuromotor reprogramming?
- 20 July 2024
- Published by Elsevier in NeuroImage
- Vol. 297, 120746
Open AccessLow-frequency sounds combined with motor imagery elicits a transient disruption of force performance: A path to neuromotor reprogramming?
- 14 July 2024
- Published by Elsevier in Neuroscience
- Vol. 554, 156-166
Brain wave modulation and EEG power changes during auditory beats stimulation
- 14 July 2024
- Published by Elsevier in Neuroscience
- Vol. 554, 156-166
Brain wave modulation and EEG power changes during auditory beats stimulation
- Open Access
- 6 November 2023
- Published by Society for Neuroscience in eneuro
- Vol. 10 (12)
Helium Optically Pumped Magnetometers Can Detect Epileptic Abnormalities as Well as SQUIDs as Shown by Intracerebral Recordings
Magnetoencephalography based on superconducting quantum interference devices (SQUIDs) has been shown to improve the diagnosis and surgical treatment decision for presurgical evaluation of drug-resistant epilepsy. Still, its use remains limited because of several constraints such as cost, fixed helmet size, and the obligation of immobility. A new generation of sensors, optically pumped magnetometers (OPMs), could overcome these limitations. In this study, we validate the ability of helium-based OPM (4He-OPM) sensors to record epileptic brain activity thanks to simultaneous recordings with intracerebral EEG [stereotactic EEG (SEEG)]. We recorded simultaneous SQUIDs-SEEG and 4He-OPM-SEEG signals in one patient during two sessions. We show that epileptic activities on intracerebral EEG can be recorded by OPMs with a better signal-to noise ratio than classical SQUIDs. The OPM sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurologic diseases and fundamental neuroscience.
- 6 November 2023
- Published by Society for Neuroscience in eneuro
- Vol. 10 (12)
Open AccessHelium Optically Pumped Magnetometers Can Detect Epileptic Abnormalities as Well as SQUIDs as Shown by Intracerebral Recordings
Magnetoencephalography based on superconducting quantum interference devices (SQUIDs) has been shown to improve the diagnosis and surgical treatment decision for presurgical evaluation of drug-resistant epilepsy. Still, its use remains limited because of several constraints such as cost, fixed helmet size, and the obligation of immobility. A new generation of sensors, optically pumped magnetometers (OPMs), could overcome these limitations. In this study, we validate the ability of helium-based OPM (4He-OPM) sensors to record epileptic brain activity thanks to simultaneous recordings with intracerebral EEG [stereotactic EEG (SEEG)]. We recorded simultaneous SQUIDs-SEEG and 4He-OPM-SEEG signals in one patient during two sessions. We show that epileptic activities on intracerebral EEG can be recorded by OPMs with a better signal-to noise ratio than classical SQUIDs. The OPM sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurologic diseases and fundamental neuroscience.
- 1 April 2017
- Published by Elsevier in Brain and Cognition
- Vol. 113, 10-22
Verbal and musical short-term memory: Variety of auditory disorders after stroke
- 1 April 2017
- Published by Elsevier in Brain and Cognition
- Vol. 113, 10-22
Verbal and musical short-term memory: Variety of auditory disorders after stroke