JDJinghan Dang

Jinghan Dang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinghan Dang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Assessment of image quality and diagnostic accuracy for cervical spondylosis using T2w-STIR sequence with a deep learning-based reconstruction approach

    by Qiuying Tao, Kaiyu Wang, Baohong Wen, Yimeng Kang, Jinghan Dang, Jieping Sun, Xiaoyu Niu, Mengzhe Zhang, Zijun Liu, Weijian Wang, et al.

    Objectives To investigate potential of enhancing image quality, maintaining interobserver consensus, and elevating disease diagnostic efficacy through the implementation of deep learning-based reconstruction (DLR) processing in 3.0 T cervical spine fast magnetic resonance imaging (MRI) images, compared with conventional images. Methods The 3.0 T cervical spine MRI images of 71 volunteers were categorized into two groups: sagittal T2-weighted short T1 inversion recovery without DLR (Sag T2w-STIR) and with DLR (Sag T2w-STIR-DLR). The assessment covered artifacts, perceptual signal-to-noise ratio, clearness of tissue interfaces, fat suppression, overall image quality, and the delineation of spinal cord, vertebrae, discs, dopamine, and joints. Spanning canal stenosis, neural foraminal stenosis, herniated discs, annular fissures, hypertrophy of the ligamentum flavum or vertebral facet joints, and intervertebral disc degeneration were evaluated by three impartial readers. Results Sag T2w-STIR-DLR images exhibited markedly superior performance across quality indicators (median = 4 or 5) compared to Sag T2w-STIR sequences (median = 3 or 4) (p < 0.001). No statistically significant differences were observed between the two sequences in terms of diagnosis and grading (p > 0.05). The interobserver agreement for Sag T2w-STIR-DLR images (0.604–0.931) was higher than the other (0.545–0.853), Sag T2w-STIR-DLR (0.747–1.000) demonstrated increased concordance between reader 1 and reader 3 in comparison to Sag T2w-STIR (0.508–1.000). Acquisition time diminished from 364 to 197 s through the DLR scheme. Conclusions Our investigation establishes that 3.0 T fast MRI images subjected to DLR processing present heightened image quality, bolstered diagnostic performance, and reduced scanning durations for cervical spine MRI compared with conventional sequences.