Zhiyong Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhiyong Yang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Daotong You
Jinan University
3 shared publications - Tuan Guo
Institute of Photonics Technology, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China
3 shared publications Wanjun Li
Wuyi University
2 shared publications- Xiangyu Yan
Key Laboratory of Bionic Engineering of Ministry of Education, Jilin University, Changchun, China
2 shared publications - Chang-Hai Lu
Institute of Photonics Technology, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, China
1 shared publication - Haochen Yan
Max Planck Institute, Science of Light, Staudtstraße 2
1 shared publication
Latest Publications
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (5) , 2428-2437
Sensitive and Repeatable Optical Fiber Hydrogen Sensors Using Plasma-Induced Oxygen Vacancies Magnetron Sputtering Coating Technique
Controlling the formation of oxygen vacancies (OVs) in metal oxide semiconductors (as the gas sensing material) is a significant important, that dominates the sensor's performances for the target of gas (sensitivity, repeatability, response time et al). In this study, we proposed a tilted fiber Bragg grating assisted hydrogen sensor with hybrid palladium and OVs-modified WO3 metal oxide semiconductors surface functionalization. The innovation of this work is that we propose an Ar plasma-etching technique to regulate OVs concentration in WO3 by adjusting magnetron sputtering power. The experimental results demonstrate that the signal-to-noise ratio of the proposed H2 sensor has been much improved, offering a limit of detection as low as 8 ppm together with a strongly enhanced reproducibility for dozens of repeat H2 measurements. This flexible coating technique offers a mass production way of high-quality specific material functionalization for various kinds of gas sensing.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (5) , 2428-2437
Sensitive and Repeatable Optical Fiber Hydrogen Sensors Using Plasma-Induced Oxygen Vacancies Magnetron Sputtering Coating Technique
Controlling the formation of oxygen vacancies (OVs) in metal oxide semiconductors (as the gas sensing material) is a significant important, that dominates the sensor's performances for the target of gas (sensitivity, repeatability, response time et al). In this study, we proposed a tilted fiber Bragg grating assisted hydrogen sensor with hybrid palladium and OVs-modified WO3 metal oxide semiconductors surface functionalization. The innovation of this work is that we propose an Ar plasma-etching technique to regulate OVs concentration in WO3 by adjusting magnetron sputtering power. The experimental results demonstrate that the signal-to-noise ratio of the proposed H2 sensor has been much improved, offering a limit of detection as low as 8 ppm together with a strongly enhanced reproducibility for dozens of repeat H2 measurements. This flexible coating technique offers a mass production way of high-quality specific material functionalization for various kinds of gas sensing.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (2) , 931-936
Multi-Channel SPR Measurement by Scanning a Fiber-Optic Probe in a Gold-Coated Silica Sleeve
Fiber-optic surface plasmon resonance (SPR) sensing has gained widespread recognition as a promising tool for biochemical analysis, yet achieving multiplexing with this technology has remained a challenge. Here, we propose and demonstrate a new fiber-optic sensing approach capable of conducting multi-channel SPR measurements. The device comprises a hetero-core optical fiber probe inserted into a gold-coated silica capillary prefilled with refractive index (RI) matching oil. The cladding modes in the hetero-core optical fiber probe extend into the silica capillary and excite the SPR effect in the gold nanofilm on the outer surface. By adjusting the position of the fiber probe inside the capillary, surface RI at different points can be sequentially measured. A five-channel sensor was experimentally constructed, showing sensitivities of ∼ 2250 nm/RIU in the RI range of 1.3327-1.3665 and inter-channel error below 1.5%. This sensing approach presents a new avenue for multi-channel biochemical sensing and demonstrates significant potential for high throughput disease diagnosis and molecular screening.
- 3 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (2) , 931-936
Multi-Channel SPR Measurement by Scanning a Fiber-Optic Probe in a Gold-Coated Silica Sleeve
Fiber-optic surface plasmon resonance (SPR) sensing has gained widespread recognition as a promising tool for biochemical analysis, yet achieving multiplexing with this technology has remained a challenge. Here, we propose and demonstrate a new fiber-optic sensing approach capable of conducting multi-channel SPR measurements. The device comprises a hetero-core optical fiber probe inserted into a gold-coated silica capillary prefilled with refractive index (RI) matching oil. The cladding modes in the hetero-core optical fiber probe extend into the silica capillary and excite the SPR effect in the gold nanofilm on the outer surface. By adjusting the position of the fiber probe inside the capillary, surface RI at different points can be sequentially measured. A five-channel sensor was experimentally constructed, showing sensitivities of ∼ 2250 nm/RIU in the RI range of 1.3327-1.3665 and inter-channel error below 1.5%. This sensing approach presents a new avenue for multi-channel biochemical sensing and demonstrates significant potential for high throughput disease diagnosis and molecular screening.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Ultrafast and Repeatable Optical Fiber Hydrogen Sensor With Urchin-Like Nanospheres Functionalization
The development of hydrogen sensors with fast response and reliable stability is the key challenge for hydrogen leak detection. Fiber-optic sensors are ideal for hydrogen sensors due to their compactness and inherent safety, but their response speed and reliable stability still need to be improved. Herein, we proposed and experimentally developed a tilted fiber Bragg grating (TFBG) fiber-optic hydrogen sensor functionalized with urchin-like $\mathrm { W_{18}O_{49}}$ nanospheres. The $\mathrm { W_{18}O_{49}}$ nanospheres have a large number of tiny spines with gas channels and active sites for capturing hydrogen molecules to enhance the reaction between the TFBG’s evanescent wave and the hydrogen molecules. Experimental results demonstrated that such sensor has an ultrafast ( $4 \sim 5$ s), highly reproducible response (99.8%) for repeat hydrogen detections with concentration from 0% to 3.0% at room temperature.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Ultrafast and Repeatable Optical Fiber Hydrogen Sensor With Urchin-Like Nanospheres Functionalization
The development of hydrogen sensors with fast response and reliable stability is the key challenge for hydrogen leak detection. Fiber-optic sensors are ideal for hydrogen sensors due to their compactness and inherent safety, but their response speed and reliable stability still need to be improved. Herein, we proposed and experimentally developed a tilted fiber Bragg grating (TFBG) fiber-optic hydrogen sensor functionalized with urchin-like $\mathrm { W_{18}O_{49}}$ nanospheres. The $\mathrm { W_{18}O_{49}}$ nanospheres have a large number of tiny spines with gas channels and active sites for capturing hydrogen molecules to enhance the reaction between the TFBG’s evanescent wave and the hydrogen molecules. Experimental results demonstrated that such sensor has an ultrafast ( $4 \sim 5$ s), highly reproducible response (99.8%) for repeat hydrogen detections with concentration from 0% to 3.0% at room temperature.