JZJunlei Zhong

Junlei Zhong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junlei Zhong has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Liang Chen

    School of Physical Science and Technology, Ningbo University, Ningbo 315211, China

    1 shared publication
  • Lixin Lei

    State Key Laboratory of Subtropical Silviculture, Zhejiang A&F University, Lin'an, 311300 Zhejiang Province, China

    1 shared publication
  • Man Shi

    State Key Laboratory of Subtropical Silviculture, Zhejiang A&F University, Lin'an, 311300 Zhejiang Province, China

    1 shared publication
  • Weiwei Huan

    College of Chemistry and Materials Engineering, Zhejiang A&F University, Hangzhou, China

    1 shared publication
  • Xuejun Yu

    State Key Laboratory for Development and Utilization of Forest Food Resources, Zhejiang A&F University, Hangzhou 311300, China

    1 shared publication
  • Yujie Chen

    State Key Laboratory of Subtropical Silviculture, Zhejiang A&F University, Lin'an, 311300 Zhejiang Province, China

    1 shared publication

Latest Publications

  • Open Access

    Determination of trace heavy metal elements in litterfall by inductively coupled plasma optical emission spectrometry after extraction using choline chloride-based deep eutectic solvents

    by Junlei Zhong, Zhikun Wang, Yujie Chen, Weiwei Huan, Man Shi, Lixin Lei, Xuejun Yu, Liang Chen

    The development of a green, safe, and accurate sample preparation method for the determination of trace metal elements in environmental samples is of great importance. Choline chloride-based deep eutectic solvents (DESs) were used to extract heavy metal elements from litterfall and the target analytes were measured using inductively coupled plasma optical emission spectrometry. Factors such as the type, ratio, dosage, and extraction time and temperature of the DESs were studied. A DES system based on choline chloride and maleic acid had the highest extraction efficiency of 98.5%, 88.4%, 90.2%, and 93.7% for Cd, Cu, Zn, and Fe. Under the optimized conditions, the limits of detection and limits of quantification were in the range of 0.04–0.70 and 0.13–2.30 mg kg−1. The repeatability (n = 3), estimated in terms of the relative standard deviation, ranged from 1.14% to 3.40%. The proposed method was validated for accuracy using GBW10087. Notably, the energy consumption of the newly developed method was only one-fifth that of a traditional acid digestion method. This work not only presents an environmentally friendly method for the determination of trace element concentrations in environmental samples but also deepens our understanding of DES systems.