Melina Koechli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Melina Koechli has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Barbara Elisabeth Ursula Burkhardt
Department of Pediatric Cardiology, University Children’s Hospital Zürich , Lengstrasse 30, 8008 Zürich
1 shared publication - Beate Rücker
Children’s Research Center, University Children’s Hospital Zurich, Zurich, Switzerland
1 shared publication - Christian Johannes Kellenberger
Department of Diagnostic Imaging, University Children’s Hospital Zurich, Zurich, Switzerland
1 shared publication - Emanuela Regina Valsangiacomo Buechel
Pediatric Heart Center, University Children’s Hospital Zürich, Zurich, Switzerland
1 shared publication - Fraser M. Callaghan
Children’s Research Center, University Children’s Hospital Zurich, Zurich, Switzerland
1 shared publication - Julia Geiger
Department of Diagnostic Imaging, University Children’s Hospital Zurich, Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
- 17 July 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (10) , 1674-1685
Accelerated cardiac magnetic resonance imaging using deep learning for volumetric assessment in children
Background: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds. Objective: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences. Material and methods: Twenty-nine consecutive patients (mean age 11 ± 5, median 12, range 1–17 years) undergoing cardiac MRI were scanned with a conventional segmented 2-D cine and a deep learning accelerated cine (three heartbeats) acquisition on a 1.5-tesla scanner. Short-axis volumetrics were performed (semi-)automatically in both datasets retrospectively by two experienced readers who visually assessed image quality employing a 4-point grading scale. Scan times and image quality were compared using the Wilcoxon rank-sum test. Volumetrics were assessed with linear regression and Bland–Altman analyses, and measurement agreement with intraclass correlation coefficient (ICC). Results: Mean acquisition time was significantly reduced with the 3-RR deep learning cine compared to the standard cine sequence (45.5 ± 13.8 s vs. 218.3 ± 44.8 s; P < 0.001). No significant differences in biventricular volumetrics were found. Left ventricular (LV) mass was increased in the deep learning cine compared with the standard cine sequence (71.4 ± 33.1 g vs. 69.9 ± 32.5 g; P < 0.05). All volumetric measurements had an excellent agreement with ICC > 0.9 except for ejection fraction (EF) (LVEF 0.81, RVEF 0.73). The image quality of deep learning cine images was decreased for end-diastolic and end-systolic contours, papillary muscles, and valve depiction (2.9 ± 0.5 vs. 3.5 ± 0.4; P < 0.05). Conclusion: Deep learning cine volumetrics did not differ significantly from standard cine results except for LV mass, which was slightly overestimated with deep learning cine. Deep learning cine sequences result in a significant reduction in scan time with only slightly lower image quality. Graphical
- 17 July 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 54 (10) , 1674-1685
Open AccessAccelerated cardiac magnetic resonance imaging using deep learning for volumetric assessment in children
Background: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds. Objective: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences. Material and methods: Twenty-nine consecutive patients (mean age 11 ± 5, median 12, range 1–17 years) undergoing cardiac MRI were scanned with a conventional segmented 2-D cine and a deep learning accelerated cine (three heartbeats) acquisition on a 1.5-tesla scanner. Short-axis volumetrics were performed (semi-)automatically in both datasets retrospectively by two experienced readers who visually assessed image quality employing a 4-point grading scale. Scan times and image quality were compared using the Wilcoxon rank-sum test. Volumetrics were assessed with linear regression and Bland–Altman analyses, and measurement agreement with intraclass correlation coefficient (ICC). Results: Mean acquisition time was significantly reduced with the 3-RR deep learning cine compared to the standard cine sequence (45.5 ± 13.8 s vs. 218.3 ± 44.8 s; P < 0.001). No significant differences in biventricular volumetrics were found. Left ventricular (LV) mass was increased in the deep learning cine compared with the standard cine sequence (71.4 ± 33.1 g vs. 69.9 ± 32.5 g; P < 0.05). All volumetric measurements had an excellent agreement with ICC > 0.9 except for ejection fraction (EF) (LVEF 0.81, RVEF 0.73). The image quality of deep learning cine images was decreased for end-diastolic and end-systolic contours, papillary muscles, and valve depiction (2.9 ± 0.5 vs. 3.5 ± 0.4; P < 0.05). Conclusion: Deep learning cine volumetrics did not differ significantly from standard cine results except for LV mass, which was slightly overestimated with deep learning cine. Deep learning cine sequences result in a significant reduction in scan time with only slightly lower image quality. Graphical