HJHaihe Jiang

Haihe Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haihe Jiang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Tingqing Cheng

    Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China

    3 shared publications
  • Lei Huang

    National Key Laboratory of Opto-Electronic Information Acquisition and Protection Technology, Anhui University, Hefei 230601, China

    2 shared publications
  • Li Wang

    Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, HeFei 230031, China

    2 shared publications
  • Tingqing Cheng

    Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Yinze Wang

    Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, China

    2 shared publications
  • Yinze Wang

    Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications

Latest Publications

  • Open Access

    Passively Q-switched 2.79-μm Er, Cr: YSGG laser based on pure water saturable absorber

    by Yinze Wang, Lei Huang, Haolin Kong, Yueyun Zhang, Tingqing Cheng, Li Wang, Haihe Jiang

    Exploring suitable saturable absorber materials for the 2.79 μm waveband is always a focus in passive Q-switching laser technology. Pure water exhibits excellent fluidity, high chemical stability, and outstanding thermal properties; notably, its recovery capability suggests it could serve as an effective saturable absorber. This study validates the feasibility of saturable absorption with absorption darkening at 2.79 μm, analyzing the saturation absorption mechanism of water and the origin of absorption darkening. By designing a device to control the thickness of micron-scale water layers, controllable outputs of Q-switched single pulses and multipulses with microsecond intervals were achieved in a 2.79 μm Er, Cr: YSGG laser. With a water layer thickness of 7 μm and a repetition rate of 20 Hz, the maximum energy of the multi-pulse output reached 0.78 mJ, and the shortest single-pulse width was 286 ns. This provides a reference for the application of pure water as a saturable absorber and for the study of other hydroxyl-based saturable absorber materials.


  • Passive Q-switching pulse characteristics of 2.79 μm Er, Cr:YSGG laser with ethanol saturable absorber

    by Yinze Wang, Lei Huang, Yueyun Zhang, Tingqing Cheng, Li Wang, Haihe Jiang

    The search for suitable saturable absorption materials for the 2.79- μm wavelength range has been a key focus in the development of passive Q-switched laser technology at this wavelength. High-purity ethanol serving as a saturable absorber operating within its intrinsic absorption darkening region is comprehensively investigated in this work. Ethanol stands out due to its high damage threshold, excellent fluidity, and long-term chemical stability, thereby making it a promising candidate for mid-infrared applications.Using a custom-designed micrometer-precision liquid cell, the ethanol layer thickness is continuously modulated from 14 μm to 55 μm (±1 μm accuracy), and passive Q-switching can be achieved without the need for an external modulator. The laser system adopts a 248- mm planar resonator, which includes a \begin{document}$\varPhi $\end{document}3 mm × 70 mm Er, Cr:YSGG rod (Cr3+ 3% (atomic percentage), Er3+ 30% (atomic percentage)), and a flashlamp pumped at 250 μs and 20 Hz. Under these conditions, the output pulse characteristics are governed almost entirely by the ethanol thickness. When the pump energy is fixed at 12.86 J, reducing the layer thickness from 55 μm to 14 μm will shorten the pulse duration from 366.1 ns to 257.9 ns and increase the single-pulse energy from 1.25 mJ to 3.48 mJ. Optimal performance, characterized by 287.6 ns pulses and 11.64 mJ energy, –is achieved at a thickness of 45 μm.While maintaining this optimal thickness, increasing the pump energy from 7.01 J to 10.75 J will further compress the pulses from 629.1 ns to 287.6 ns and increases the output energy from 0.52 mJ to 11.64 mJ, none of which do not cause optical damage, indicating a damage threshold exceeding 10 J/cm2. At pump energies exceeding 8.4 J, the ethanol undergoes re-bleaching within its ~20 μs recovery time, resulting in the formation of 2–5 equally spaced nanosecond sub-pulses (6–12 μs spacing, effective repetition ≈ 100 kHz) within a single pump envelope, which is an operating regime highly favorable for precision laser ablation.The beam quality at maximum output is measured to be \begin{document}$ M_x^2 =7.51 $\end{document} and \begin{document}$ M_y^2 =7.51 $\end{document}. These results are supported by rate-equation modeling combined with temperature-dependent absorption cross-sections from the HITRAN database, establishing ethanol as an adjustable, high-damage-threshold liquid saturable absorber for compact mid-infrared Q-switched lasers, and emphasizing the broader potential of hydroxyl-containing liquids for next-generation medical and spectroscopic applications.

  • The Robustness of an Anti‐Noise BP Neural Network Inversion Algorithm for Ground‐Based Microwave Radiometer

    by Shijie Sun, Huaqiao Gui, Haihe Jiang, Tingqing Cheng

    The ground‐based microwave radiometer (MWR) retrieves atmospheric profiles with a high temporal resolution for temperature and relative humidity up to a height of 10 km. These profiles have been widely used in the field of meteorological observation. Due to the inherent fragility of neural networks, one of the important issues in this field is to improve the reliability and stability of MWR profiles based on neural network inversion. We propose a deep learning method that adds noise to the BP neural network inversion (NBPNN) process. Comparison of the radiosonde data and NBPNN results shows that if the error of MWR brightness temperature is in the range of −2–2 K, the root‐mean‐square error (RMSE) of the temperature profile is 2.15 K, and the RMSE of the relative humidity profile is 19.46 % inverted by NBPNN. The results are much less than the errors of the temperature profile and relative humidity profile inverted by the traditional backpropagation neural network inverse method. From the comparison, we demonstrated that NBPNN significantly increases the inversion accuracy and robustness under the condition of errors in brightness temperature, which can reduce requirements for BT accuracy of MWR and achieve MWR long‐term stability.


  • Open Access

    Mid-Infrared 2.79 μm Band Er, Cr: Y3Sc2Ga3O12 Laser Transmission Anti-Bending Low-Loss Anti-Resonant Hollow-Core Fiber

    by Lei Huang, Peng Wang, Yinze Wang, Tingqing Cheng, Li Wang, Haihe Jiang

    A large core size and bending resistance are very important properties of mid-infrared energy transfer fibers, but large core sizes usually lead to the deterioration of bending properties. A negative-curvature nested node-free anti-resonant hollow-core fiber (AR-HCF) based on quartz is proposed. It was made by adding a nested layer to a previous AR-HCF design to provide an additional anti-resonance region while keeping the gap between adjacent tubes strictly correlated with the core diameter to produce a node-free structure. These features improve the fiber’s bending resistance while achieving a larger core diameter. The simulation results show that the radial air–glass anti-resonant layer is increased by the introduction of the nested anti-resonant tube, and the weak interference overlap between the fiber core and the cladding mode is reduced, so the fiber core’s limiting loss and sensitivity to bending are effectively reduced. When the capillary wall thickness t of the fiber is 0.71 μm, the core diameter D is 70 μm, the ratio of the inner diameter of the cladding capillary to the core diameter d/D is 0.62, the diameter of the nested tube is d0 = 29 μm, the fiber has a lower limiting loss at the wavelength of 2.79 μm, and the limiting loss is 3.28 × 10−4 dB/m. At the same time, the optimized structure also has good bending resistance. When the bending radius is 30 mm, the bending loss is only 4.72 × 10−2 dB/m. An anti-bending low-loss micro-structure hollow fiber with a bending radius of less than 30 mm was successfully achieved in the 2.79 μm band. An anti-bending low-loss anti-resonant hollow-core fiber with this structure constitutes a reliable choice for the light guiding system of a 2.79 μm band Er, Cr: YSGG laser therapy instrument.


  • Open Access

    Mid-Infrared 2.79 μm Band Er, Cr: YSGG Laser Transmission Anti-Bending Low-Loss Anti-Resonant Hollow-Core Fiber

    by Lei Huang, Peng Wang, Ze Yin Wang, Qing Ting Cheng, Li Wang, Haihe Jiang

    A large core size and bending resistance are very important properties of mid-infrared energy transfer fibers, but large core sizes usually lead to a deterioration of bending properties. A negative-curvature nested node-free anti-resonant hollow-core fiber (AR-HCF) based on quartz is proposed. It was made by adding a nested layer to a previous AR-HCF design to provide an additional anti-resonance region while keeping the gap between adjacent tubes strictly correlated to the core diameter to produce a node-free structure. These features improve the fiber’s bending resistance while achieving a larger core diameter. The simulation results show that the radial air-glass anti-resonant layer is increased by the introduction of the nested anti-resonant tube, and the weak interference overlap between the fiber core and the cladding mode is reduced, so the fiber core’s limiting loss and the sensitivity to bending are effectively reduced. When the capillary wall thickness t of the fiber is 0.71 μm, the core diameter D is 70 μm, the ratio of the inner diameter of the cladding capillary to the core diameter d/D is 0.62, and the diameter of the nested tube is d0=29 μm, the fiber has a lower limiting loss at the wavelength of 2.79 μm, and the limiting loss is 3.28×10-4 dB/m. At the same time, the optimized structure also has good bending resistance. When the bending radius is 30 mm, the bending loss is only 4.72×10-2 dB/m. To our knowledge, this is the first research to achieve an anti-bending low-loss micro-structure hollow fiber with a bending radius of less than 30 mm in the 2.79 μm band. An anti-bending low-loss anti-resonant hollow-core fiber with this structure constitutes a reliable choice for the light guiding system of a 2.79 μm band erbium laser therapy instrument.