Ci Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ci Song has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Shu-Guang Yu
Acupuncture and Tuina School, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China
2 shared publications - Xinxin Li
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
2 shared publications - Zheng Yu
School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China
2 shared publications - Chuanbiao Wen
School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China
1 shared publication - Hang Yin
College of Materials and Chemistry, China Jiliang University, Hangzhou 310018, China
1 shared publication - Ke Sun
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
1 shared publication
Latest Publications
- Open Access
- 30 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1256
An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response
Real-time monitoring of local muscle response during acupuncture could reveal mechanisms underlying acupuncture and provide objective feedback to support more precise needle control. However, the small dimensions of acupuncture needles impose stringent constraints on sensor miniaturization and packaging. This study presents an ultraminiature pressure sensor integrated into the tip of a 450-μm-diameter acupuncture needle. The sensor measures 200 × 1250 × 50 μm3 and incorporates an elongated pressure-sensitive diaphragm. Wafer-level AuSn solder deposition and thermocompression soldering connect the chip to an ultrafine wire ribbon routed through the 230-μm-diameter needle lumen. A 1.3-μm-thick Parylene C coating provides electrical insulation. After coating, the sensor exhibited a sensitivity of 40.3 μV/kPa at a 3.3 V excitation, retaining 78.4% of its uncoated sensitivity. Characterization over 90–150 kPa absolute and 25–45 °C yielded a maximum nonlinearity of approximately 0.73% of full scale (FS). The coated sensor exhibited a maximum hysteresis of 2.52% FS. In vivo experiments at the Zusanli acupoint in rats recorded pressure variations during thrusting–lifting manipulation. These results demonstrate the feasibility of monitoring local muscle response during acupuncture and their potential to provide quantitative feedback for needle manipulation.
- 30 October 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1256
Open AccessAn Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response
Real-time monitoring of local muscle response during acupuncture could reveal mechanisms underlying acupuncture and provide objective feedback to support more precise needle control. However, the small dimensions of acupuncture needles impose stringent constraints on sensor miniaturization and packaging. This study presents an ultraminiature pressure sensor integrated into the tip of a 450-μm-diameter acupuncture needle. The sensor measures 200 × 1250 × 50 μm3 and incorporates an elongated pressure-sensitive diaphragm. Wafer-level AuSn solder deposition and thermocompression soldering connect the chip to an ultrafine wire ribbon routed through the 230-μm-diameter needle lumen. A 1.3-μm-thick Parylene C coating provides electrical insulation. After coating, the sensor exhibited a sensitivity of 40.3 μV/kPa at a 3.3 V excitation, retaining 78.4% of its uncoated sensitivity. Characterization over 90–150 kPa absolute and 25–45 °C yielded a maximum nonlinearity of approximately 0.73% of full scale (FS). The coated sensor exhibited a maximum hysteresis of 2.52% FS. In vivo experiments at the Zusanli acupoint in rats recorded pressure variations during thrusting–lifting manipulation. These results demonstrate the feasibility of monitoring local muscle response during acupuncture and their potential to provide quantitative feedback for needle manipulation.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Development and Testing of an On-Machine Measurement System for Shape Error of Deep-Hole Parts Based on Electromagnetic Acoustic Wall Thickness Method
Precision deep-hole parts are extensively utilized across various sectors of industrial production, and their machining quality exerts a significant influence on numerous variables, such as fatigue limits, geometric precision, and product stability. On-machine measurement is a critical method to assess geometric features and guide the subsequent processing stage. This technique boasts substantial benefits, including immediacy, interactive capabilities, and widespread recognition within the metrology domain, particularly for the assessment of large-scale parts. As a crucial metric for appraising the machining quality of deep-hole parts, the measurement of roundness and axis straightness errors is paramount in ensuring the functional integrity of deep-hole products. Utilizing the wall thickness method, a multisensor integrated measurement system for these two categories of shape errors has been developed. This system employs an electromagnetic acoustic transducer (EMAT), an eddy current sensor, a laser interferometer, and a rotary encoder. Pertinent to this system, an uncertainty analysis model for roundness and axis straightness errors is devised. The effectiveness of the measurement system is verified by experiments.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Development and Testing of an On-Machine Measurement System for Shape Error of Deep-Hole Parts Based on Electromagnetic Acoustic Wall Thickness Method
Precision deep-hole parts are extensively utilized across various sectors of industrial production, and their machining quality exerts a significant influence on numerous variables, such as fatigue limits, geometric precision, and product stability. On-machine measurement is a critical method to assess geometric features and guide the subsequent processing stage. This technique boasts substantial benefits, including immediacy, interactive capabilities, and widespread recognition within the metrology domain, particularly for the assessment of large-scale parts. As a crucial metric for appraising the machining quality of deep-hole parts, the measurement of roundness and axis straightness errors is paramount in ensuring the functional integrity of deep-hole products. Utilizing the wall thickness method, a multisensor integrated measurement system for these two categories of shape errors has been developed. This system employs an electromagnetic acoustic transducer (EMAT), an eddy current sensor, a laser interferometer, and a rotary encoder. Pertinent to this system, an uncertainty analysis model for roundness and axis straightness errors is devised. The effectiveness of the measurement system is verified by experiments.
- Open Access
- 19 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 924
A Flexible Temperature Sensor Integrated at Needle Tip for In Situ Acupoint Temperature Monitoring
Temperature can reflect vital activities, and researchers have attempted to guide Chinese medicine diagnosis and treatment by observing acupoint temperature changes. Integrating a temperature sensor at the needle tip enables in situ acupoint temperature measurement. However, the sensor needles for acupoint temperature monitoring designed in previous studies were fabricated by manually soldering thermistor beads and metal wires, making mass production difficult. In this work, using MEMS manufacturing technology, a flexible temperature sensor that can be integrated at the needle tip is proposed and can be mass-produced on silicon wafers. The sensor uses a Pt thermistor as the temperature-sensing element and has a slender flexible structure with dimensions of 125 μm width by 3.2 cm length. As the sensor is inserted into a hollow needle, the Pt thermistor is glued to the needle tip. In the temperature range of 30 °C to 50 °C, the fabricated temperature sensor has a sensitivity of 5.00 Ω∙°C−1, a nonlinearity of ±0.39%FS, and a repeatability error of ±2.62%FS. Additionally, the sensor has been applied to in vivo acupoint temperature monitoring experiments in rats and demonstrated good performance, suggesting its promise for future research on acupoint temperature.
- 19 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 924
Open AccessA Flexible Temperature Sensor Integrated at Needle Tip for In Situ Acupoint Temperature Monitoring
Temperature can reflect vital activities, and researchers have attempted to guide Chinese medicine diagnosis and treatment by observing acupoint temperature changes. Integrating a temperature sensor at the needle tip enables in situ acupoint temperature measurement. However, the sensor needles for acupoint temperature monitoring designed in previous studies were fabricated by manually soldering thermistor beads and metal wires, making mass production difficult. In this work, using MEMS manufacturing technology, a flexible temperature sensor that can be integrated at the needle tip is proposed and can be mass-produced on silicon wafers. The sensor uses a Pt thermistor as the temperature-sensing element and has a slender flexible structure with dimensions of 125 μm width by 3.2 cm length. As the sensor is inserted into a hollow needle, the Pt thermistor is glued to the needle tip. In the temperature range of 30 °C to 50 °C, the fabricated temperature sensor has a sensitivity of 5.00 Ω∙°C−1, a nonlinearity of ±0.39%FS, and a repeatability error of ±2.62%FS. Additionally, the sensor has been applied to in vivo acupoint temperature monitoring experiments in rats and demonstrated good performance, suggesting its promise for future research on acupoint temperature.
- 1 October 2007
- Published by Elsevier in Optical Materials
- Vol. 30 (2) , 207-211
Spectroscopic properties of Nd3+:(La,Sr)(Al,Ta)O3 crystal
- 1 October 2007
- Published by Elsevier in Optical Materials
- Vol. 30 (2) , 207-211
Spectroscopic properties of Nd3+:(La,Sr)(Al,Ta)O3 crystal