He Li
Research Subjects
He Li has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chaobin Wang
Northeast Electric Power University, Jilin City, China
1 shared publication - Chong Wang
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin 132012, China
1 shared publication - Peng Su
State Grid East Inner Mongolia Electric Power Co., Ltd., Hohhot, Inner Mongolia Autonomous Region, China
1 shared publication - Wei Liang
Tongliao Power Supply Company, State Grid East Inner Mongolia Electric Power Co., Ltd., Tongliao 028007, China
1 shared publication - Wei Zhou
Tongliao Power Supply Company, State Grid East Inner Mongolia Electric Power Co., Ltd., Tongliao 028007, China
1 shared publication - Weiqi Zhang
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
1 shared publication
Latest Publications
- Open Access
Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage
The increasing penetration of photovoltaic (PV) generation introduces substantial uncertainties into microgrid energy management due to deviations between forecasted and actual generation and load demand. Conventional single-time-scale scheduling may impose additional regulation demands on batteries, increasing energy throughput, power fluctuations, and associated degradation costs. To address these challenges, this paper proposes a forecast-error-aware dual-time-scale hierarchical energy management strategy for a grid-connected PV microgrid equipped with a battery–supercapacitor hybrid energy storage system. The upper layer performs hourly economic scheduling by considering grid electricity transactions and battery degradation costs, while the lower layer conducts corrective optimization at 5 min intervals using updated source-load forecasts. Through receding-horizon optimization, reference tracking, and battery power-variation regulation, corrective power is coordinated among the battery, supercapacitor, and utility grid while respecting their operating constraints. A 48 h benchmark with three comparative strategies is conducted under a 10% normalized root mean square error (NRMSE), with all cases terminating at 10% battery SOC. Compared with conventional battery-based hourly scheduling, the proposed strategy reduces the total operating cost, battery energy throughput, and the battery power fluctuation index by 4.34%, 16.69%, and 38.40%, respectively. An additional 96 h evaluation, with battery SOC restored to 50% at successive period boundaries, retains a 9.96% reduction in the power fluctuation index but yields a higher operating cost and battery throughput. Sensitivity analysis under 5–20% NRMSE further shows relatively stable battery power fluctuations and increased supercapacitor utilization with forecasting uncertainty. These findings demonstrate the potential benefits of forecast-aware hierarchical coordination while indicating that economic and battery utilization outcomes depend on the operating scenario, evaluation horizon, and terminal-energy policy.
Open AccessForecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage
The increasing penetration of photovoltaic (PV) generation introduces substantial uncertainties into microgrid energy management due to deviations between forecasted and actual generation and load demand. Conventional single-time-scale scheduling may impose additional regulation demands on batteries, increasing energy throughput, power fluctuations, and associated degradation costs. To address these challenges, this paper proposes a forecast-error-aware dual-time-scale hierarchical energy management strategy for a grid-connected PV microgrid equipped with a battery–supercapacitor hybrid energy storage system. The upper layer performs hourly economic scheduling by considering grid electricity transactions and battery degradation costs, while the lower layer conducts corrective optimization at 5 min intervals using updated source-load forecasts. Through receding-horizon optimization, reference tracking, and battery power-variation regulation, corrective power is coordinated among the battery, supercapacitor, and utility grid while respecting their operating constraints. A 48 h benchmark with three comparative strategies is conducted under a 10% normalized root mean square error (NRMSE), with all cases terminating at 10% battery SOC. Compared with conventional battery-based hourly scheduling, the proposed strategy reduces the total operating cost, battery energy throughput, and the battery power fluctuation index by 4.34%, 16.69%, and 38.40%, respectively. An additional 96 h evaluation, with battery SOC restored to 50% at successive period boundaries, retains a 9.96% reduction in the power fluctuation index but yields a higher operating cost and battery throughput. Sensitivity analysis under 5–20% NRMSE further shows relatively stable battery power fluctuations and increased supercapacitor utilization with forecasting uncertainty. These findings demonstrate the potential benefits of forecast-aware hierarchical coordination while indicating that economic and battery utilization outcomes depend on the operating scenario, evaluation horizon, and terminal-energy policy.
- 20 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (2) , 1707-1717
A dual time scale Voltage/Var control method for active distribution networks based on data-driven
- 20 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (2) , 1707-1717
A dual time scale Voltage/Var control method for active distribution networks based on data-driven