Yangyi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yangyi Huang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
6 shared publications - Tian Han
Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
2 shared publications Xiaoliao Peng
Department of Ophthalmology, Fudan University, Shanghai, China
2 shared publications- Aruma Aruma
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
1 shared publication - Biyun Zhan
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
1 shared publication Can Chen
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China; NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China; Shanghai Research Center of Ophthalmology and Optometry, China; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, China
1 shared publication
Latest Publications
- Open Access
- 10 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (10) , 3670
Evaluation of a Novel Autostereoscopic Three-Dimensional System for Binocular Visual Function: A Comparative Validation Study
Background/Objectives: Autostereoscopic three-dimensional (3D) technology represents a promising tool for ophthalmic examinations. However, prior studies have largely focused on stereopsis alone in cooperative adults, leaving comprehensive validation across multiple binocular domains and diverse patient groups unexplored. This study introduces the head-to-head evaluation of a novel integrated, glasses-free autostereoscopic 3D system. The system could simultaneously assess four essential binocular functions (simultaneous perception, fusion, stereoacuity, and stereopsis), with a single automated workflow featuring real-time eye tracking. This study aimed to assess the comparative performance of the novel autostereoscopic 3D display in evaluating binocular visual function, as a preliminary potential screening tool benchmarked against conventional screening tests. Methods: A total of 232 participants (age: 3–60 years; male/female: 125/107) were recruited. All participants sequentially underwent binocular visual function assessments using autostereoscopic 3D technology, anaglyphic 3D technology (red–green glasses), and the Titmus stereopsis test. Pearson correlation analysis, Phi coefficient, Cohen’s Kappa and Bland–Altman plots were conducted to assess the consistency. Receiver operating characteristic curve analysis was employed to evaluate the screening comparative performance of autostereoscopic 3D technology, using the anaglyphic 3D technology and the Titmus stereopsis test as comparative reference standards. Results: Relative to anaglyphic 3D technology, agreement for simultaneous perception (φ = 0.527, κ = 0.425) and fusion (φ = 0.520, κ = 0.503) was moderate (all p < 0.001). Compared to the Titmus stereopsis test, agreement for stereoacuity levels (r = 0.779, κ = 0.659) and for stereopsis detection (φ = 0.624, κ = 0.619) was substantial (all p < 0.001). The areas under the curve for identifying abnormal binocular visual function using autostereoscopic 3D technology were 0.769 for overall binocular vision function, 0.747 for simultaneous perception, 0.730 for fusion, 0.846 for stereoacuity, and 0.810 for stereopsis (all p < 0.001). Sensitivities and specificities ranged from 52.8 to 81.7% and 77.9–93.1%, respectively. Conclusions: Autostereoscopic 3D technology demonstrated significant correlation and moderate agreement with traditional methods in assessing binocular visual function, particularly for stereopsis assessment.
- 10 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (10) , 3670
Open AccessEvaluation of a Novel Autostereoscopic Three-Dimensional System for Binocular Visual Function: A Comparative Validation Study
Background/Objectives: Autostereoscopic three-dimensional (3D) technology represents a promising tool for ophthalmic examinations. However, prior studies have largely focused on stereopsis alone in cooperative adults, leaving comprehensive validation across multiple binocular domains and diverse patient groups unexplored. This study introduces the head-to-head evaluation of a novel integrated, glasses-free autostereoscopic 3D system. The system could simultaneously assess four essential binocular functions (simultaneous perception, fusion, stereoacuity, and stereopsis), with a single automated workflow featuring real-time eye tracking. This study aimed to assess the comparative performance of the novel autostereoscopic 3D display in evaluating binocular visual function, as a preliminary potential screening tool benchmarked against conventional screening tests. Methods: A total of 232 participants (age: 3–60 years; male/female: 125/107) were recruited. All participants sequentially underwent binocular visual function assessments using autostereoscopic 3D technology, anaglyphic 3D technology (red–green glasses), and the Titmus stereopsis test. Pearson correlation analysis, Phi coefficient, Cohen’s Kappa and Bland–Altman plots were conducted to assess the consistency. Receiver operating characteristic curve analysis was employed to evaluate the screening comparative performance of autostereoscopic 3D technology, using the anaglyphic 3D technology and the Titmus stereopsis test as comparative reference standards. Results: Relative to anaglyphic 3D technology, agreement for simultaneous perception (φ = 0.527, κ = 0.425) and fusion (φ = 0.520, κ = 0.503) was moderate (all p < 0.001). Compared to the Titmus stereopsis test, agreement for stereoacuity levels (r = 0.779, κ = 0.659) and for stereopsis detection (φ = 0.624, κ = 0.619) was substantial (all p < 0.001). The areas under the curve for identifying abnormal binocular visual function using autostereoscopic 3D technology were 0.769 for overall binocular vision function, 0.747 for simultaneous perception, 0.730 for fusion, 0.846 for stereoacuity, and 0.810 for stereopsis (all p < 0.001). Sensitivities and specificities ranged from 52.8 to 81.7% and 77.9–93.1%, respectively. Conclusions: Autostereoscopic 3D technology demonstrated significant correlation and moderate agreement with traditional methods in assessing binocular visual function, particularly for stereopsis assessment.
- Open Access
- 8 July 2025
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 10 (1) , e001963
Clinical science effects of different mydriatics on retinal and choroidal parameters in healthy adults observed by widefield swept-source optical coherence tomography
Purpose: To assess retinal and choroidal changes following rapid mydriasis in healthy adults. Methods: Seventy-one volunteers (71 right eyes) participated in a prospective randomised controlled trial. They were divided into two groups: tropicamide (n=36) and a mixture (tropicamide:phenylephrine=1:1, n=35) groups. Ophthalmic examinations included visual acuity, intraocular pressure and axial length measurements. Ultra-widefield swept-source optical coherence tomography angiography was used to assess retinal and choroidal parameters before and after mydriasis. This technique covers a 24×20 mm² area, allowing for non-invasive, simultaneous structural and haemodynamic assessment of retinal and choroidal regions. Results: Both central (tropicamide: 33.3%; mixture: 22.22%) and mid-peripheral (tropicamide: 28.47%; mixture: 36.81%) retinas thickened slightly postmydriasis (p> 0.05, FDR corrected). Conclusions: Rapid mydriasis causes slight retinal thickening, the slight change in the outer layer, particularly in the temporal and inferior regions. There were no significant changes in the choroid parameters following mydriasis, except for choroidal stroma volume. The limitation of this study was the small sample size and the absence of a control group.
- 8 July 2025
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 10 (1) , e001963
Open AccessClinical science effects of different mydriatics on retinal and choroidal parameters in healthy adults observed by widefield swept-source optical coherence tomography
Purpose: To assess retinal and choroidal changes following rapid mydriasis in healthy adults. Methods: Seventy-one volunteers (71 right eyes) participated in a prospective randomised controlled trial. They were divided into two groups: tropicamide (n=36) and a mixture (tropicamide:phenylephrine=1:1, n=35) groups. Ophthalmic examinations included visual acuity, intraocular pressure and axial length measurements. Ultra-widefield swept-source optical coherence tomography angiography was used to assess retinal and choroidal parameters before and after mydriasis. This technique covers a 24×20 mm² area, allowing for non-invasive, simultaneous structural and haemodynamic assessment of retinal and choroidal regions. Results: Both central (tropicamide: 33.3%; mixture: 22.22%) and mid-peripheral (tropicamide: 28.47%; mixture: 36.81%) retinas thickened slightly postmydriasis (p> 0.05, FDR corrected). Conclusions: Rapid mydriasis causes slight retinal thickening, the slight change in the outer layer, particularly in the temporal and inferior regions. There were no significant changes in the choroid parameters following mydriasis, except for choroidal stroma volume. The limitation of this study was the small sample size and the absence of a control group.
- 13 June 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 1-11
Ten-year outcomes of effective optical zone and decentration analysis after keratorefractive lenticule extraction for moderate and high myopia
To investigate ten-year changes in the effective optical zone (EOZ) and decentration after keratorefractive lenticule extraction (KLEx) for moderate and high myopia. In this prospective study, 27 patients (48 eyes, spherical equivalent: -6.34 ± 1.19 D) were enrolled and treated with KLEx. Follow-up was conducted 10 years postoperatively. The EOZ and decentration were calculated using custom software based on the tangential corneal curvature maps. The relationships among keratometry, corneal wavefront aberrations, EOZ, and decentration were evaluated. Ten years postoperatively, the safety and efficacy indexes were 1.14 ± 0.19 and 1.05 ± 0.25, respectively. The EOZ diameter was 5.31 ± 0.26 mm. In the longitudinal analysis, the percentages of (1-EOZ/POZ) were 31.02 ± 1.02%, 31.14 ± 1.08%, 33.22 ± 1.06%, and 34.91 ± 1.02% at postoperative 1 month, 1 year, 5 years, and 10 years. The differences between preoperative and postoperative higher-order aberrations (HOAs) were 0.23 ± 0.02 μm, 0.24 ± 0.02 μm, 0.21 ± 0.02 μm, 0.17 ± 0.02 μm. The factors influencing the EOZ percentages were time (p = 0.002), correction cylinders (p = 0.005), and interaction between correction cylinders and spheres (p = 0.014), and the factors influencing HOAs inductions were time (p = 0.001), scotopic pupil (p = 0.001), postoperative decentration (p < 0.001), EOZ diameter (p = 0.030), and the interaction between decentration and EOZ diameter (p = 0.002). The decentration was 0.39 ± 0.15 mm at the last follow-up, which was statistically unchanged throughout the follow-up. KLEx is safe and effective for patients with moderate or high myopia in the long term. The EOZ decreased slightly but was broadly stable, and the decentration remained stable during the 10-year follow-up.
- 13 June 2025
- Published by Springer Nature in Lasers in Medical Science
- Vol. 40 (1) , 1-11
Ten-year outcomes of effective optical zone and decentration analysis after keratorefractive lenticule extraction for moderate and high myopia
To investigate ten-year changes in the effective optical zone (EOZ) and decentration after keratorefractive lenticule extraction (KLEx) for moderate and high myopia. In this prospective study, 27 patients (48 eyes, spherical equivalent: -6.34 ± 1.19 D) were enrolled and treated with KLEx. Follow-up was conducted 10 years postoperatively. The EOZ and decentration were calculated using custom software based on the tangential corneal curvature maps. The relationships among keratometry, corneal wavefront aberrations, EOZ, and decentration were evaluated. Ten years postoperatively, the safety and efficacy indexes were 1.14 ± 0.19 and 1.05 ± 0.25, respectively. The EOZ diameter was 5.31 ± 0.26 mm. In the longitudinal analysis, the percentages of (1-EOZ/POZ) were 31.02 ± 1.02%, 31.14 ± 1.08%, 33.22 ± 1.06%, and 34.91 ± 1.02% at postoperative 1 month, 1 year, 5 years, and 10 years. The differences between preoperative and postoperative higher-order aberrations (HOAs) were 0.23 ± 0.02 μm, 0.24 ± 0.02 μm, 0.21 ± 0.02 μm, 0.17 ± 0.02 μm. The factors influencing the EOZ percentages were time (p = 0.002), correction cylinders (p = 0.005), and interaction between correction cylinders and spheres (p = 0.014), and the factors influencing HOAs inductions were time (p = 0.001), scotopic pupil (p = 0.001), postoperative decentration (p < 0.001), EOZ diameter (p = 0.030), and the interaction between decentration and EOZ diameter (p = 0.002). The decentration was 0.39 ± 0.15 mm at the last follow-up, which was statistically unchanged throughout the follow-up. KLEx is safe and effective for patients with moderate or high myopia in the long term. The EOZ decreased slightly but was broadly stable, and the decentration remained stable during the 10-year follow-up.
- 11 February 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 48 (3) , 102384
Evaluation of large language models for providing educational information in orthokeratology care
- 11 February 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 48 (3) , 102384
Evaluation of large language models for providing educational information in orthokeratology care
- Open Access
- 17 January 2025
- Published by Taylor & Francis in Annals of Medicine
- Vol. 57 (1) , 2453628
Changes in the effective optical zone following hyperopic keratorefractive lenticule extraction
To evaluate the longitudinal changes in the effective optical zone (EOZ) following hyperopic keratorefractive lenticule extraction (KLEx) and investigate factors influencing the EOZ. This retrospective study included 27 patients who underwent hyperopic KLEx. According to the transition zone (TZ) sizes, they were divided into two groups: group A (21 eyes) with a 2.0-mm TZ and group B (10 eyes) with a 0 or 0.2-mm TZ. The programmed treatment zone (PTZ) was the sum of the programmed optical zone (POZ) and the TZ.. Changes in the EOZ were evaluated at the early (within 1 month postoperatively) and late (over 6 months postoperatively) postoperative stages. The effects of the surgical and corneal topographic parameters on EOZ were explored. A significantly higher postoperative spherical equivalent was found in group B than in group A (p = 0.002). The early and late EOZ diameters were 4.27 ± 0.20 mm and 4.04 ± 0.21 mm in group A, and 3.48 ± 0.29 and 3.12 ± 0.49 mm in group B, respectively. ΔEOZ/POZ and ΔEOZ/PTZ were significantly larger at the late than the early postoperative stage in both groups (p < 0.001), with a larger ΔEOZ/POZ value in group B than that in group A at both stages (p < 0.001). EOZ reduction was negatively associated with POZ at the late postoperative stage (ΔEOZ/POZ: p = 0.043; ΔEOZ/PTZ: p = 0.020). The EOZ continued decreasing following hyperopic KLEx. A larger TZ and POZ would result in a larger postoperative EOZ.
- 17 January 2025
- Published by Taylor & Francis in Annals of Medicine
- Vol. 57 (1) , 2453628
Open AccessChanges in the effective optical zone following hyperopic keratorefractive lenticule extraction
To evaluate the longitudinal changes in the effective optical zone (EOZ) following hyperopic keratorefractive lenticule extraction (KLEx) and investigate factors influencing the EOZ. This retrospective study included 27 patients who underwent hyperopic KLEx. According to the transition zone (TZ) sizes, they were divided into two groups: group A (21 eyes) with a 2.0-mm TZ and group B (10 eyes) with a 0 or 0.2-mm TZ. The programmed treatment zone (PTZ) was the sum of the programmed optical zone (POZ) and the TZ.. Changes in the EOZ were evaluated at the early (within 1 month postoperatively) and late (over 6 months postoperatively) postoperative stages. The effects of the surgical and corneal topographic parameters on EOZ were explored. A significantly higher postoperative spherical equivalent was found in group B than in group A (p = 0.002). The early and late EOZ diameters were 4.27 ± 0.20 mm and 4.04 ± 0.21 mm in group A, and 3.48 ± 0.29 and 3.12 ± 0.49 mm in group B, respectively. ΔEOZ/POZ and ΔEOZ/PTZ were significantly larger at the late than the early postoperative stage in both groups (p < 0.001), with a larger ΔEOZ/POZ value in group B than that in group A at both stages (p < 0.001). EOZ reduction was negatively associated with POZ at the late postoperative stage (ΔEOZ/POZ: p = 0.043; ΔEOZ/PTZ: p = 0.020). The EOZ continued decreasing following hyperopic KLEx. A larger TZ and POZ would result in a larger postoperative EOZ.
- 1 November 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (11) , 1157-1164
Comparison of long-term visual quality after keratorefractive lenticule extraction and implantable collamer lens V4c for high myopia
Purpose: To compare the long-term refractive outcomes and visual quality after keratorefractive lenticule extraction (KLEx) and EVO-implantable collamer lens (ICL) implantation for high myopia. Setting: Eye & ENT Hospital of Fudan University, Shanghai, China. Design: Retrospective study. Methods: This study included 31 KLEx-treated patients (31 eyes, spherical equivalent: −7.62 ± 1.22 diopters [D]) and 32 ICL-treated patients (32 eyes, spherical equivalent: −8.22 ± 1.18 D). Refractive outcomes and objective visual quality were examined. Subjective visual quality was evaluated by a customized questionnaire. Patients' satisfaction was graded. Results: 5 years postoperatively, the efficacy (KLEx: 0.96 ± 0.20; ICL: 1.03 ± 0.20; P = .164) and safety indices (KLEx: 1.12 ± 0.20; ICL: 1.21 ± 0.19; P = .067) were comparable. Statistically higher proportions of ICL-treated eyes achieved a postoperative uncorrected distance visual acuity of 20/20 or better (P = .035). Refractive predictability was similar between the 2 groups (P = .947), whereas more KLEx-treated eyes had myopic refractive errors (P < .001). Total coma was significantly higher after KLEx (P = .020), and greater total trefoil was observed after ICL implantation (P = .006). Haloes were the primary visual disturbance in both groups (KLEx: 64.5%; ICL: 93.8%). The incidences of haloes (P < .001), glare (P = .004), and starbursts (P = .043) were notably higher after ICL implantation. The patient's satisfaction scores were similar (KLEx: 9.10 ± 1.27; ICL: 9.10 ± 1.27; P = .894). Conclusions: For high myopia, EVO-ICL yielded better long-term refractive outcomes than KLEx. Haloes were the chief concern in both groups, with a significantly higher incidence after ICL implantation.
- 1 November 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (11) , 1157-1164
Comparison of long-term visual quality after keratorefractive lenticule extraction and implantable collamer lens V4c for high myopia
Purpose: To compare the long-term refractive outcomes and visual quality after keratorefractive lenticule extraction (KLEx) and EVO-implantable collamer lens (ICL) implantation for high myopia. Setting: Eye & ENT Hospital of Fudan University, Shanghai, China. Design: Retrospective study. Methods: This study included 31 KLEx-treated patients (31 eyes, spherical equivalent: −7.62 ± 1.22 diopters [D]) and 32 ICL-treated patients (32 eyes, spherical equivalent: −8.22 ± 1.18 D). Refractive outcomes and objective visual quality were examined. Subjective visual quality was evaluated by a customized questionnaire. Patients' satisfaction was graded. Results: 5 years postoperatively, the efficacy (KLEx: 0.96 ± 0.20; ICL: 1.03 ± 0.20; P = .164) and safety indices (KLEx: 1.12 ± 0.20; ICL: 1.21 ± 0.19; P = .067) were comparable. Statistically higher proportions of ICL-treated eyes achieved a postoperative uncorrected distance visual acuity of 20/20 or better (P = .035). Refractive predictability was similar between the 2 groups (P = .947), whereas more KLEx-treated eyes had myopic refractive errors (P < .001). Total coma was significantly higher after KLEx (P = .020), and greater total trefoil was observed after ICL implantation (P = .006). Haloes were the primary visual disturbance in both groups (KLEx: 64.5%; ICL: 93.8%). The incidences of haloes (P < .001), glare (P = .004), and starbursts (P = .043) were notably higher after ICL implantation. The patient's satisfaction scores were similar (KLEx: 9.10 ± 1.27; ICL: 9.10 ± 1.27; P = .894). Conclusions: For high myopia, EVO-ICL yielded better long-term refractive outcomes than KLEx. Haloes were the chief concern in both groups, with a significantly higher incidence after ICL implantation.
- Open Access
- 17 February 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 839545
Prognostic Nomograms Predicting Risk of Keratoconus in Very Asymmetric Ectasia: Combined Corneal Tomographic and Biomechanical Assessments
Purpose: The aim of the study was to develop and validate a prognostic nomogram for subclinical keratoconus diagnosis using corneal tomographic and biomechanical integration assessments.Design: This is a retrospective case–control study.Methods:Setting: The study was carried out in a hospital setting. Patients: The study included patients with very asymmetric ectasia (VAE) and normal controls. Patients with VAE had defined clinical ectasia in one eye and normal topography (VAE-NT) in the fellow eye, and VAE-NT eyes were selected for analysis. VAE-NT was defined as stratified stage 0 using the ABCD keratoconus grading system. The normal control group was selected from corneal refractive surgery candidates at our clinic, and the right eye was enrolled. Observation Procedures: Scheimpflug-based corneal tomography (Pentacam) and corneal biomechanical assessment (Corvis ST) were performed. Main Outcome Measures: We performed multiple logistic regression analysis and constructed a simple nomogram via the stepwise method. The receiver operating characteristic (ROC) curve and discrimination and calibration of prognostic nomogram were performed by 500 bootstrap resamplings to assess the determination and clinical value, respectively.Results: A total of 59 VAE-NT and 142 normal eyes were enrolled. For differentiating normal and VAE-NT eyes, the values of specificity, sensitivity, and area under the ROC (AUROC) were 0.725, 0.610, and 0.713 for tomographic parameters, 0.886, 0.632, and 0.811 for biomechanical parameters, and 0.871, 0.754, and 0.849 for combined parameters, respectively. Combined parameters showed better predictability than separated tomographic or biomechanical parameters.Conclusion: Our nomogram developed with combined tomographic and biomechanical parameters demonstrated a plausible, capable, and widely implementable tool to predict risk of keratoconus. The identification of at-risk patients can provide advanced strategies to epitomize ectasia susceptibility.
- 17 February 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 839545
Open AccessPrognostic Nomograms Predicting Risk of Keratoconus in Very Asymmetric Ectasia: Combined Corneal Tomographic and Biomechanical Assessments
Purpose: The aim of the study was to develop and validate a prognostic nomogram for subclinical keratoconus diagnosis using corneal tomographic and biomechanical integration assessments.Design: This is a retrospective case–control study.Methods:Setting: The study was carried out in a hospital setting. Patients: The study included patients with very asymmetric ectasia (VAE) and normal controls. Patients with VAE had defined clinical ectasia in one eye and normal topography (VAE-NT) in the fellow eye, and VAE-NT eyes were selected for analysis. VAE-NT was defined as stratified stage 0 using the ABCD keratoconus grading system. The normal control group was selected from corneal refractive surgery candidates at our clinic, and the right eye was enrolled. Observation Procedures: Scheimpflug-based corneal tomography (Pentacam) and corneal biomechanical assessment (Corvis ST) were performed. Main Outcome Measures: We performed multiple logistic regression analysis and constructed a simple nomogram via the stepwise method. The receiver operating characteristic (ROC) curve and discrimination and calibration of prognostic nomogram were performed by 500 bootstrap resamplings to assess the determination and clinical value, respectively.Results: A total of 59 VAE-NT and 142 normal eyes were enrolled. For differentiating normal and VAE-NT eyes, the values of specificity, sensitivity, and area under the ROC (AUROC) were 0.725, 0.610, and 0.713 for tomographic parameters, 0.886, 0.632, and 0.811 for biomechanical parameters, and 0.871, 0.754, and 0.849 for combined parameters, respectively. Combined parameters showed better predictability than separated tomographic or biomechanical parameters.Conclusion: Our nomogram developed with combined tomographic and biomechanical parameters demonstrated a plausible, capable, and widely implementable tool to predict risk of keratoconus. The identification of at-risk patients can provide advanced strategies to epitomize ectasia susceptibility.