JHJun-Hyeok Heo

Jun-Hyeok Heo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jun-Hyeok Heo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of Ball Bearing Structure and Material: Parasitic Capacitance, Shaft Voltage, and Electrostatic Discharge

    by Byoung-Wook Jo, Jun-Hyeok Heo, Jin Hur

    Bearings are essential mechanical components that support the rotating shaft and reduce friction, thereby enabling the stable operation of mechanical systems. However, bearings are simultaneously subjected not only to mechanical loads but also to electrical stress induced by shaft voltage. Because the clearance between conductive components such as the inner race, outer race, and balls is extremely small, electrostatic discharge can occur even at low shaft voltages. Such discharge phenomena lead to electrical discharge machining (EDM), which accelerates wear and surface damage on the inner race, outer race, and balls, ultimately resulting in bearing failure. To mitigate electrical corrosion, ceramic ball bearings have recently been adopted for the drive-side bearings in traction motors for electric vehicles (EVs). Also, due to the extremely small clearances between the inner race, outer race, and balls, bearings inherently exhibit relatively high parasitic capacitance compared to their size, which significantly influences shaft voltage characteristics. Nevertheless, research focusing on shaft voltage behavior associated with bearings remains limited. Therefore, this study investigates the parasitic capacitance, shaft voltage, and electrostatic discharge characteristics of ball bearings as functions of bearing structure and material. Furthermore, the analytical results are experimentally validated.

  • FPCB Hybrid Shield-Based Method for Integrated Shaft Voltage Reduction and Fault Diagnosis

    by Jun-Hyeok Heo, Jun-Kyu Kang, Sung-Won Lee, Jin Hur

    Recently, with the advancement of high-performance electric vehicles (EVs), there has been a growing trend toward high-voltage battery systems. As a result, while the performance of EVs improves, the risk of bearing electrical erosion faults due to shaft voltage in motors also increases. The occurrence of bearing electrical erosion faults causes cracks in the balls, inner race, and outer race of the bearing. In addition, when damage occurs to the bearing that supports the rotor shaft of the motor, dynamic eccentricity faults (DEFs) or static eccentricity faults (SEFs) may additionally occur. Bearing electrical erosion faults caused by shaft voltage, as well as eccentricity faults caused by bearing damage or motor assembly, can lead to serious vehicle faults. Therefore, this study proposes a flexible printed circuit board (FPCB)-based hybrid shield to reduce shaft voltage in motors and prevent bearing electrical erosion faults, and also to diagnose bearing or eccentricity faults at an early stage when they occur. To verify the reliability of this study, experimental validation was conducted with a focus on practical demonstration.


  • Analysis of Shaft Voltage Generation Mechanism in Wound Field Synchronous Motor

    by Jun-Hyeok Heo, Dong-In Lee, Byoung-Wook Jo, Han-Shin Youn, Jin Hur

    With the expansion of high-voltage systems and the increasing demand for electric motors, bearing electrical erosion faults caused by shaft voltage have been continuously raised as an issue in electric vehicle (EV), urban air mobility (UAM), railway, and generator. Due to bearing electrical erosion fault, the rotor’s central axis becomes exposed to the risk of eccentricity fault caused by misalignment. Therefore, since bearing electrical erosion faults are closely related to other mechanical faults, research on shaft voltage that causes bearing electrical erosion faults is essential. In addition, due to technical, economic, and environmental reasons, the demand for and research on wound field synchronous motor (WFSM) continue to increase. In this study, to respond to bearing electrical erosion faults that may occur due to shaft voltage in WFSM and to ensure reliability, an analysis of the shaft voltage mechanism in WFSM was conducted. Furthermore, to validate the research, an experimental environment was established, and empirical verification was performed.


  • A New Eccentricity Fault Diagnosis Method for IPMSM Using Variable Reluctance Resolver

    by Jun-Kyu Kang, Jun-Hyeok Heo, Seong-Won Lee, Jin Hur

    Bearing faults, a major fault in interior permanent magnet synchronous motors (IPMSMs), can arise from eccentricity. Static eccentricity fault (SEF) mainly occurs due to incorrect manufacturing processes and mechanical impacts from external sources. However, existing fault diagnosis methods often suffer from reduced accuracy due to the attachment of additional sensors or external electrical noise. This paper proposes a new fault diagnosis method using a variable reluctance (VR) resolver to diagnose eccentricity faults (EF) in IPMSMs. Initially, the VR resolver used for fault diagnosis was modeled using a magnetic equivalent circuit. Subsequently, the characteristics of both the healthy and EF states of IPMSMs and VR resolvers were analyzed using the finite element method (FEM). Finally, the effectiveness of the proposed fault diagnosis method was verified through experiments.


  • Open Access

    3-D FE Analysis of Magnet Segmentation for Optimizing Thrust Force and Eddy Current Loss of Arc Linear Servo Motor

    by Zuhair Abbas, Jun-Hyeok Heo, Ikhlaq Ahmad, Jun-Kyu Kang, Jin Hur

    When employing high-magnetic co-energy sintered NdFeB magnets, permanent magnet linear synchronous machines (PMLSMs) exhibit several advantages over traditional induction and direct current machines, including greater thrust capability and efficiency. However, during operation at high frequencies, significant eddy current losses in the permanent magnet (PM) can result in elevated temperatures, increasing the risk of irreversible demagnetization. This issue is further compounded by the large air gap in such machines, making the thrust force a critical factor for ensuring efficient performance. A complete magnet segmentation (CMS) can be an effective method for reducing the PM eddy current losses, but it reduces the thrust characteristics and mechanical robustness of the PMLSM. Therefore, a partial magnet segmentation (PMS), namely, single-side PMS (SSPMS), is studied for the new arc-structured PMLSM to optimize the eddy current loss and thrust force. A comparison between the initial PM, CMS, and SSPMS is performed using the Ansys Maxwell 3-D finite element analysis (FEA) tool. The results demonstrate that the SSPMS configuration significantly reduces PM eddy current loss while maintaining the same thrust force. Moreover, it offers superior mechanical robustness and lower manufacturing costs compared to the conventional CMS.


  • Open Access

    Robust Design Optimization Considering Static Eccentricity Fault of Six-Phase IPMSM

    by Jun-Kyu Kang, Dae-Hyeon Kim, Jun-Hyeok Heo, Jin Hur

    Static eccentricity fault (SEF) primarily occurs due to external mechanical shocks and incorrect manufacturing processes. In the case of SEF condition, vibration and noise in the electric motor are generated due to unbalanced magnetic forces. Additionally, SEF conditions lead to an increase in the iron loss of motor due to the unbalanced air gap flux density. As iron loss increases, the temperature of the main part of the motor increases, which has a negative effect. Therefore, this paper presents a robust design optimization model where the characteristics of a six-phase interior permanent magnet synchronous motor (IPMSM) do not change drastically even when SEF occurs. First, magnetic flux density, iron loss, and efficiency according to the rotor shape are analyzed using the finite element method (FEM). Second, under identical stator structure conditions, characteristics derived from the finite element method (FEM) are verified through experiments analyzing different rotor shapes. Finally, robust design optimization is performed to ensure that the motor characteristics do not change drastically even when SEF occurs.


  • Open Access

    Reduction of Shaft Voltage of IPMSM According to the Shape of the Novel Shield Ring

    by Jun-Kyu Kang, Jun-Hyeok Heo, Su-Hwan Kim, Jin Hur

    Recently, the motor drive system of electric vehicles (EVs) has been increased to high voltage to enhance the output and efficiency of the motor. However, higher voltage exacerbates common-mode voltage (CMV), which is the main cause of bearing faults. Due to the CMV component, the shaft voltage of the motor is generated, shortening the life of the bearing and, in severe cases, causing serious motor faults due to bearing damage. Therefore, it is very important to reduce the shaft voltage of the motor. This paper proposes a method of reducing shaft voltage by applying a shield ring of a novel structure to the stator part of the interior permanent magnet synchronous motor (IPMSM). First, the parasitic capacitance and shaft voltage equivalent circuit model of the IPMSM are analyzed. The effect of the shaft voltage according to the material of the shield ring is then analyzed. In addition, changes in shaft voltage size are analyzed according to the shape of the shield ring. Finally, the proposed method was verified through experiments.


  • Open Access

    Verification of Shaft Voltage Reduction Effect Using Layered-Shield in EV Traction Motors

    by Jun-Hyeok Heo, Jun-Kyu Kang, Jin Hur

    Shaft voltage generated in electric vehicle (EV) motors is a critical issue as it can lead to motor performance degradation and damage, potentially resulting in vehicle fault and endangering the driver’s safety. To prevent such faults, a newly structured layered shield based on flexible printed circuit board (FPCB) has been proposed, and its effectiveness in reducing shaft voltage was experimentally verified when applied to a scaled-down traction motor. This study experimentally investigates the effect of the layered shield on shaft voltage reduction in an interior permanent magnet synchronous motor (IPMSM) type EV traction motor under various operating conditions. The results demonstrate that the application of the layered shield reduced shaft voltage by 80 % in high-voltage systems, significantly enhancing motor durability and preventing faults. This paper presents the effectiveness and applicability of the layered shield in addressing shaft voltage issues in EV traction motors, highlighting its potential to prevent motor faults that are directly related to driver safety.


  • Proposing the New Layered-Shield Structure for Shaft Voltage Reduction in IPMSM

    by Jun-Hyeok Heo, Jun-Kyu Kang, Jun-Hyuk Im, Jin Hur

    As the era of electrification advances, the demand for increased power density and high efficiency in electric motors, such as those in electric vehicles and E-mobility, has been rising. This has led to an increase in the application of higher DC voltages and the use of high-performance switching devices. In particular, with the design of high-performance interior permanent magnet synchronous motors (IPMSM), which are widely used as traction motors in many vehicles, there is a growing need to address motor faults. IPMSMs are driven by PWM inverters for traction motors, and during this process, a common mode voltage (CMV) occurs, where the sum of the three-phase voltages of the winding does not become zero. This CMV component causes circulating currents through the parasitic capacitances within the motor from the windings, generating current paths. As a result, voltage is induced on the motor shaft, which applies voltage to the bearings, leading to bearing damage. Such bearing faults can cause mechanical and electrical defects in the motor and even lead to vehicle breakdowns. Therefore, since bearing faults can threaten the driver’s life, this paper proposes a new shield structure designed to reduce shaft voltage and prevent bearing faults.


  • Utilization of Multiple Planar Search Coils for Diagnosing Imbalance Irreversible Demagnetization Faults in PMSMs Along the z-Axis

    by Jun-Hyuk Im, Jun-Kyu Kang, Jun-Hyeok Heo, Jin Hur

    Permanent magnet synchronous motors are widely employed in various fields due to their excellent efficiency and output characteristics. However, magnets are susceptible to irreversible demagnetization faults (IDF), where their magnetic properties degrade due to stresses such as external magnetic fields and high temperature condition. IDF can deteriorate motor performance and even lead to catastrophic failures like control failures. Therefore, there is a need to study diagnostic techniques for IDF. Various diagnostic techniques have been proposed; However, due to the uneven distribution of stresses, such as heat and magnetic flux, on the motor magnets, IDF exhibit non-uniformity along the z-axis direction. Most of fault detection method cannot provide diagnostics for individual magnet segments. In this paper, a fault diagnosis technique using planar search coils attached to the surface of the motor's stator is introduced. The planar search coils can be fabricated in various shapes, allowing for the arrangement of multiple coils along the z-axis of the motor to acquire signals based on the flux linkage on each coil. This technique is validated through finite element method and experiments. As a result, it is confirmed that the proposed technique allows for fault diagnosis in both the non-excited and excited states using the acquired signals.