Chae Young Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chae Young Lim has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Sung Tae Kim
Department of Radiology and Center for Imaging Sciences, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
4 shared publications - Beomseok Sohn
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
3 shared publications - Eung Yeop Kim
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
3 shared publications - Minjung Seong
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
3 shared publications - Yongsik Sim
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
3 shared publications - So Yeon Won
Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea
2 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Comparative evaluation of automated MRI-based brain volumetry software for estimating cognitive domains in early Alzheimer’s disease
Brain volumetry software is widely accepted for assessment in Alzheimer’s disease. However, direct comparisons for software-specific prediction capab
- 6 July 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessComparative evaluation of automated MRI-based brain volumetry software for estimating cognitive domains in early Alzheimer’s disease
Brain volumetry software is widely accepted for assessment in Alzheimer’s disease. However, direct comparisons for software-specific prediction capab
- Open Access
- 1 January 2025
- Published by XMLink in Korean Journal of Radiology
- Vol. 26 (8) , 771-781
Effect of Deep Learning-Based Artificial Intelligence on Radiologists’ Performance in Identifying Nigrosome 1 Abnormalities on Susceptibility Map-Weighted Imaging
Park J, et al. Korean J Radiol. 2025 Aug;26(8):771-781. https://doi.org/10.3348/kjr.2025.0208
- 1 January 2025
- Published by XMLink in Korean Journal of Radiology
- Vol. 26 (8) , 771-781
Open AccessEffect of Deep Learning-Based Artificial Intelligence on Radiologists’ Performance in Identifying Nigrosome 1 Abnormalities on Susceptibility Map-Weighted Imaging
Park J, et al. Korean J Radiol. 2025 Aug;26(8):771-781. https://doi.org/10.3348/kjr.2025.0208
- Open Access
- 1 January 2025
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 29 (2) , 120-123
Leber Hereditary Optic Neuropathy and Stroke-Like Lesions Associated With MT-ND5 m.13513G>A Mutation: A Case Report
Lim CY, et al. Investig Magn Reson Imaging. 2025 Jun;29(2):120-123. https://doi.org/10.13104/imri.2025.0014
- 1 January 2025
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 29 (2) , 120-123
Open AccessLeber Hereditary Optic Neuropathy and Stroke-Like Lesions Associated With MT-ND5 m.13513G>A Mutation: A Case Report
Lim CY, et al. Investig Magn Reson Imaging. 2025 Jun;29(2):120-123. https://doi.org/10.13104/imri.2025.0014
- 14 December 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (6) , 1223-1230
The Inferior Cerebellar Peduncle Sign: A Novel Imaging Marker for Differentiating Multiple System Atrophy Cerebellar Type from Spinocerebellar Ataxia
BACKGROUND AND PURPOSE: The hot cross bun (HCB) sign is a hallmark feature of multiple system atrophy with predominant cerebellar ataxia (MSA-C), typically observed in advanced stages of the disease; however, it can also present in other conditions such as spinocerebellar ataxia (SCA), making the differentiation challenging. The middle cerebellar peduncle (MCP) sign may be observed in various medical conditions and in healthy individuals. We hypothesized that the inferior cerebellar peduncle (ICP), known to be affected in MSA-C, may exhibit hyperintensity on fluid-attenuated inversion recovery (FLAIR) imaging, potentially aiding in differentiating MSA-C from SCA. MATERIALS AND METHODS: Medical records of 153 probable MSA-C and 72 genetically confirmed SCAs from a single institution were reviewed retrospectively between January 2012 and June 2023. MRI was performed using 3-Tesla scanners. The ICP sign was deemed positive when the bilateral ICP signal intensity exceeded that of the medulla oblongata on axial FLAIR images. MCP and HCB signs were also evaluated. Two independent neuroradiologists evaluated all MRIs, and interobserver agreement was assessed using Kappa statistics. Univariable and multivariable logistic regression analyses identified predictive features and diagnostic performance was assessed. RESULTS: The ICP sign was more prevalent in patients with MSA-C (65%) compared to those with SCA (6.9%; P < .001). HCB and MCP signs were more frequent in patients with MSA-C (n = 110 and n = 134) than in those with SCA (n = 19 and n = 30; P<.001). The ICP sign demonstrated the highest specificity (95%) for predicting MSA-C, with an AUC of 0.82, respectively. The MCP sign exhibited superior sensitivity (87%) but lower specificity and AUC compared to the ICP sign. Combining the ICP and MCP signs improved the AUC to 0.86. Integrating clinical features (age, sex, and disease duration) with imaging features yielded excellent diagnostic performance, with an AUC of 0.98. CONCLUSIONS: The ICP sign on FLAIR imaging exhibits high specificity in distinguishing MSA-C from SCA. Integrating clinical and imaging features further enhances diagnostic accuracy, potentially improving differential diagnosis in clinical settings of cerebellar ataxia. ABBREVIATIONS: AUC = area under the curve; HCB = hot cross bun; ICP = inferior cerebellar peduncle; ICI = integrated calibration index; IQR = interquartile range; IRB = Institutional Review Board; MCP = middle cerebellar peduncle; MDS = Movement Disorder Society; MSA = multiple system atrophy; MSA-C = multiple system atrophy with predominant cerebellar ataxia; SCA = spinocerebellar ataxia.
- 14 December 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (6) , 1223-1230
The Inferior Cerebellar Peduncle Sign: A Novel Imaging Marker for Differentiating Multiple System Atrophy Cerebellar Type from Spinocerebellar Ataxia
BACKGROUND AND PURPOSE: The hot cross bun (HCB) sign is a hallmark feature of multiple system atrophy with predominant cerebellar ataxia (MSA-C), typically observed in advanced stages of the disease; however, it can also present in other conditions such as spinocerebellar ataxia (SCA), making the differentiation challenging. The middle cerebellar peduncle (MCP) sign may be observed in various medical conditions and in healthy individuals. We hypothesized that the inferior cerebellar peduncle (ICP), known to be affected in MSA-C, may exhibit hyperintensity on fluid-attenuated inversion recovery (FLAIR) imaging, potentially aiding in differentiating MSA-C from SCA. MATERIALS AND METHODS: Medical records of 153 probable MSA-C and 72 genetically confirmed SCAs from a single institution were reviewed retrospectively between January 2012 and June 2023. MRI was performed using 3-Tesla scanners. The ICP sign was deemed positive when the bilateral ICP signal intensity exceeded that of the medulla oblongata on axial FLAIR images. MCP and HCB signs were also evaluated. Two independent neuroradiologists evaluated all MRIs, and interobserver agreement was assessed using Kappa statistics. Univariable and multivariable logistic regression analyses identified predictive features and diagnostic performance was assessed. RESULTS: The ICP sign was more prevalent in patients with MSA-C (65%) compared to those with SCA (6.9%; P < .001). HCB and MCP signs were more frequent in patients with MSA-C (n = 110 and n = 134) than in those with SCA (n = 19 and n = 30; P<.001). The ICP sign demonstrated the highest specificity (95%) for predicting MSA-C, with an AUC of 0.82, respectively. The MCP sign exhibited superior sensitivity (87%) but lower specificity and AUC compared to the ICP sign. Combining the ICP and MCP signs improved the AUC to 0.86. Integrating clinical features (age, sex, and disease duration) with imaging features yielded excellent diagnostic performance, with an AUC of 0.98. CONCLUSIONS: The ICP sign on FLAIR imaging exhibits high specificity in distinguishing MSA-C from SCA. Integrating clinical and imaging features further enhances diagnostic accuracy, potentially improving differential diagnosis in clinical settings of cerebellar ataxia. ABBREVIATIONS: AUC = area under the curve; HCB = hot cross bun; ICP = inferior cerebellar peduncle; ICI = integrated calibration index; IQR = interquartile range; IRB = Institutional Review Board; MCP = middle cerebellar peduncle; MDS = Movement Disorder Society; MSA = multiple system atrophy; MSA-C = multiple system atrophy with predominant cerebellar ataxia; SCA = spinocerebellar ataxia.
- Open Access
- 1 January 2024
- Published by XMLink in Yonsei Medical Journal
- Vol. 65 (10) , 611-618
Need for Transparency and Clinical Interpretability in Hemorrhagic Stroke Artificial Intelligence Research: Promoting Effective Clinical Application
Lim CY, et al. Yonsei Med J. 2024 Jul;65:e48. https://doi.org/10.3349/ymj.2024.0007
- 1 January 2024
- Published by XMLink in Yonsei Medical Journal
- Vol. 65 (10) , 611-618
Open AccessNeed for Transparency and Clinical Interpretability in Hemorrhagic Stroke Artificial Intelligence Research: Promoting Effective Clinical Application
Lim CY, et al. Yonsei Med J. 2024 Jul;65:e48. https://doi.org/10.3349/ymj.2024.0007
- 1 January 2010
- Published by Elsevier in Environmental Modelling & Software
- Vol. 25 (1) , 158-169
Statistical properties of differences between low and high resolution CMAQ runs with matched initial and boundary conditions
- 1 January 2010
- Published by Elsevier in Environmental Modelling & Software
- Vol. 25 (1) , 158-169
Statistical properties of differences between low and high resolution CMAQ runs with matched initial and boundary conditions