Marcin Jurczak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcin Jurczak has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Majkowski
Faculty of Electrical Engineering, Warsaw University of Technology, pl. Politechniki 1, 00-661 Warsaw, Poland
5 shared publications - Marcin Kołodziej
Faculty of Electrical Engineering, Warsaw University of Technology, pl. Politechniki 1, 00-661 Warsaw, Poland
5 shared publications Andrzej Rysz
1 shared publication- Andrzej Rysz
1st Military Clinical Hospital with Outpatient Clinic, Municipal Non-Profit Healthcare Facility in Lublin Neurosurgery Department, ul. Kościuszki 30, 19-300 Ełk, Poland
1 shared publication - Bartosz Świderski
Department of Artificial Intelligence, Institute of Information Technology, Warsaw University of Life Sciences, ul. Nowoursynowska 159, 02-776 Warsaw, Poland
1 shared publication Bruno Andò
1 shared publication
Latest Publications
- 19 December 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (1) , 50-75
Method for epileptic spike detection in EEG signals contaminated by muscle artifacts
- 19 December 2025
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (1) , 50-75
Method for epileptic spike detection in EEG signals contaminated by muscle artifacts
- Open Access
- 29 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4953
A Hybrid CNN-LSTM Approach for Muscle Artifact Removal from EEG Using Additional EMG Signal Recording
Removing artifacts from electroencephalography (EEG) signals is a common technique. Although numerous algorithms have been proposed, most rely solely on EEG data. In this study, we introduce a novel approach utilizing a hybrid convolutional neural network–long short-term memory (CNN-LSTM) architecture alongside simultaneous recording of facial and neck EMG signals. This setup enables the precise elimination of artifacts from the EEG signal. To validate the method, we collected a dataset from 24 participants who were presented with a light-emitting diode (LED) stimulus that elicited steady-state visual evoked potentials (SSVEPs) while they performed strong jaw clenching, an action known to induce significant artifacts. We then assessed the algorithm’s ability to remove artifacts while preserving SSVEP responses. The results were compared against other commonly used algorithms, such as independent component analysis and linear regression. The findings demonstrate that the proposed method exhibits excellent performance, effectively removing artifacts while retaining the EEG signal’s useful components.
- 29 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4953
Open AccessA Hybrid CNN-LSTM Approach for Muscle Artifact Removal from EEG Using Additional EMG Signal Recording
Removing artifacts from electroencephalography (EEG) signals is a common technique. Although numerous algorithms have been proposed, most rely solely on EEG data. In this study, we introduce a novel approach utilizing a hybrid convolutional neural network–long short-term memory (CNN-LSTM) architecture alongside simultaneous recording of facial and neck EMG signals. This setup enables the precise elimination of artifacts from the EEG signal. To validate the method, we collected a dataset from 24 participants who were presented with a light-emitting diode (LED) stimulus that elicited steady-state visual evoked potentials (SSVEPs) while they performed strong jaw clenching, an action known to induce significant artifacts. We then assessed the algorithm’s ability to remove artifacts while preserving SSVEP responses. The results were compared against other commonly used algorithms, such as independent component analysis and linear regression. The findings demonstrate that the proposed method exhibits excellent performance, effectively removing artifacts while retaining the EEG signal’s useful components.
- Open Access
Acquisition and Analysis of Facial Electromyographic Signals for Emotion Recognition
The objective of the article is to recognize users’ emotions by classifying facial electromyographic (EMG) signals. A biomedical signal amplifier, equipped with eight active electrodes positioned in accordance with the Facial Action Coding System, was used to record the EMG signals. These signals were registered during a procedure where users acted out various emotions: joy, sadness, surprise, disgust, anger, fear, and neutral. Recordings were made for 16 users. The mean power of the EMG signals formed the feature set. We utilized these features to train and evaluate various classifiers. In the subject-dependent model, the average classification accuracies were 96.3% for KNN, 94.9% for SVM with a linear kernel, 94.6% for SVM with a cubic kernel, and 93.8% for LDA. In the subject-independent model, the classification results varied depending on the tested user, ranging from 91.4% to 48.6% for the KNN classifier, with an average accuracy of 67.5%. The SVM with a cubic kernel performed slightly worse, achieving an average accuracy of 59.1%, followed by the SVM with a linear kernel at 53.9%, and the LDA classifier at 41.2%. Additionally, the study identified the most effective electrodes for distinguishing between pairs of emotions.
Open AccessAcquisition and Analysis of Facial Electromyographic Signals for Emotion Recognition
The objective of the article is to recognize users’ emotions by classifying facial electromyographic (EMG) signals. A biomedical signal amplifier, equipped with eight active electrodes positioned in accordance with the Facial Action Coding System, was used to record the EMG signals. These signals were registered during a procedure where users acted out various emotions: joy, sadness, surprise, disgust, anger, fear, and neutral. Recordings were made for 16 users. The mean power of the EMG signals formed the feature set. We utilized these features to train and evaluate various classifiers. In the subject-dependent model, the average classification accuracies were 96.3% for KNN, 94.9% for SVM with a linear kernel, 94.6% for SVM with a cubic kernel, and 93.8% for LDA. In the subject-independent model, the classification results varied depending on the tested user, ranging from 91.4% to 48.6% for the KNN classifier, with an average accuracy of 67.5%. The SVM with a cubic kernel performed slightly worse, achieving an average accuracy of 59.1%, followed by the SVM with a linear kernel at 53.9%, and the LDA classifier at 41.2%. Additionally, the study identified the most effective electrodes for distinguishing between pairs of emotions.
- 14 May 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 284-287
Comparison of Independent Component Analysis, Linear Regression and Adaptive Filtering for Artifact Removal in SSVEP Registration
Artifacts pose a significant challenge in the analysis of EEG signals. In this study, the authors investigated the impact of artifacts on the detection of steady-state visually evoked potentials (SSVEPs). The article explored various techniques for physiological artifact elimination, including linear regression, adaptive filters, and independent component analysis (ICA). The effectiveness of the algorithms was evaluated using classification accuracy as a metric. The results indicate that the most promising outcomes were achieved with independent component analysis.
- 14 May 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 284-287
Comparison of Independent Component Analysis, Linear Regression and Adaptive Filtering for Artifact Removal in SSVEP Registration
Artifacts pose a significant challenge in the analysis of EEG signals. In this study, the authors investigated the impact of artifacts on the detection of steady-state visually evoked potentials (SSVEPs). The article explored various techniques for physiological artifact elimination, including linear regression, adaptive filters, and independent component analysis (ICA). The effectiveness of the algorithms was evaluated using classification accuracy as a metric. The results indicate that the most promising outcomes were achieved with independent component analysis.
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (6) , 1-4
Study of the Impact of Physiological Artifacts on SSVEP Acquisition
Steady-state visually evoked potentials (SSVEPs) are recorded from the visual cortex and are widely used for brain–computer interfaces. Artifacts caused by muscle activity [electromyography (EMG)] and eye movements [electrooculography (EOG)] can reach several millivolts, while brain activity signals [electroencephalography (EEG)] have only several microvolts. EEG signals can be distorted by various types of artifacts. The authors are not aware of any works that have assessed the impact of such artifacts on the registration of SSVEP. In this letter, we examined the influence of different types of artifacts on the power of the EEG signal recorded from the visual cortex. Artifacts were recorded from 12 participants using eight EMG/EOG and eight EEG electrodes. We also identified the locations where it is worth recording EOG/EMG signals to use them to remove artifacts. Our results show that neck strain, swallowing, jaw clenching, and wincing are the most disruptive artifacts for SSVEP.
- 19 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (6) , 1-4
Study of the Impact of Physiological Artifacts on SSVEP Acquisition
Steady-state visually evoked potentials (SSVEPs) are recorded from the visual cortex and are widely used for brain–computer interfaces. Artifacts caused by muscle activity [electromyography (EMG)] and eye movements [electrooculography (EOG)] can reach several millivolts, while brain activity signals [electroencephalography (EEG)] have only several microvolts. EEG signals can be distorted by various types of artifacts. The authors are not aware of any works that have assessed the impact of such artifacts on the registration of SSVEP. In this letter, we examined the influence of different types of artifacts on the power of the EEG signal recorded from the visual cortex. Artifacts were recorded from 12 participants using eight EMG/EOG and eight EEG electrodes. We also identified the locations where it is worth recording EOG/EMG signals to use them to remove artifacts. Our results show that neck strain, swallowing, jaw clenching, and wincing are the most disruptive artifacts for SSVEP.