Felix Hennig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felix Hennig has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Knosalla
Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery, Augustenburger Platz 1, 13353 Berlin, Germany; Charité - Universitätsmedizin Berlin, Corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany; German Center for Cardiovascular Research (DZHK), Partnersite Berlin, 10785 Berlin, Germany
6 shared publications - Felix Schoenrath
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC) , Berlin
3 shared publications - Volkmar Falk
Deutsches Herzzentrum der Charité, Charité University Medicine Berlin , Berlin
3 shared publications - Andreas Wallinder
Transplant Institute, Sahlgrenska University Hospital, Gothenburg, Sweden
2 shared publications - Andreas Zuckermann
Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Vienna, Austria
2 shared publications - Arezu Aliabadi-Zuckermann
Department of Cardiac- and Thoracic Aortic Surgery, Medical University of Vienna , Währinger Gürtel 18-20, Vienna A-1090
2 shared publications
Latest Publications
- Open Access
- 16 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (32) , 4523-4526
Hypothermic oxygenated perfusion versus standard treatment of donor hearts in heart transplantation: extended follow-up of the NIHP2019 trial
- 16 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (32) , 4523-4526
Open AccessHypothermic oxygenated perfusion versus standard treatment of donor hearts in heart transplantation: extended follow-up of the NIHP2019 trial
- Open Access
- 25 July 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (10) , 2087-2101
Left ventricular diastolic function assessed by speckle tracking echocardiography in patients with left ventricular aneurysm
Speckle-tracking echocardiography (STE) parameters are an integral part of the assessment of left ventricular (LV) function. We aimed to evaluate established and novel STE parameters of LV diastolic function and their prognostic role in patients with LV anteroapical aneurysm undergoing surgical ventricular repair (SVR). We retrospectively examined the data of 137 patients with anteroapical LV aneurysm who underwent SVR. In 27 patients, the correlation of STE parameters with invasive hemodynamic parameters was evaluated. Preoperative echocardiographic parameters were assessed for their association with outcome, defined as all-cause mortality, LV assist device implantation, or heart transplantation. The late diastolic strain rate (GLSRa) showed a stronger correlation with mean pulmonary artery pressure (r = − 0.75, p < 0.001) than all other parameters. GLSRa was also significantly correlated with mean pulmonary capillary wedge pressure and LV end-diastolic pressure. In the multivariate model, GLSRa and the ratio of early diastolic filling velocity to GLSRa demonstrated incremental prognostic value in addition to clinical and echocardiographic parameters. Patients with GLSRa < 0.59 s−1 had significantly shorter event-free survival than those with GLSRa > 0.59 s−1 (6.7 vs. 10.9 years, p < 0.001). Peak reservoir left atrial strain showed a weaker association with hemodynamic parameters and outcome compared to GLSRa. In patients with LV aneurysm, late diastolic strain rate and left atrial strain can be used for the assessment of LV diastolic function and have a predictive value for the outcome after surgical ventricular restoration. Graphical
- 25 July 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (10) , 2087-2101
Open AccessLeft ventricular diastolic function assessed by speckle tracking echocardiography in patients with left ventricular aneurysm
Speckle-tracking echocardiography (STE) parameters are an integral part of the assessment of left ventricular (LV) function. We aimed to evaluate established and novel STE parameters of LV diastolic function and their prognostic role in patients with LV anteroapical aneurysm undergoing surgical ventricular repair (SVR). We retrospectively examined the data of 137 patients with anteroapical LV aneurysm who underwent SVR. In 27 patients, the correlation of STE parameters with invasive hemodynamic parameters was evaluated. Preoperative echocardiographic parameters were assessed for their association with outcome, defined as all-cause mortality, LV assist device implantation, or heart transplantation. The late diastolic strain rate (GLSRa) showed a stronger correlation with mean pulmonary artery pressure (r = − 0.75, p < 0.001) than all other parameters. GLSRa was also significantly correlated with mean pulmonary capillary wedge pressure and LV end-diastolic pressure. In the multivariate model, GLSRa and the ratio of early diastolic filling velocity to GLSRa demonstrated incremental prognostic value in addition to clinical and echocardiographic parameters. Patients with GLSRa < 0.59 s−1 had significantly shorter event-free survival than those with GLSRa > 0.59 s−1 (6.7 vs. 10.9 years, p < 0.001). Peak reservoir left atrial strain showed a weaker association with hemodynamic parameters and outcome compared to GLSRa. In patients with LV aneurysm, late diastolic strain rate and left atrial strain can be used for the assessment of LV diastolic function and have a predictive value for the outcome after surgical ventricular restoration. Graphical
- 3 May 2024
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 121 (9) , 302
Correspondence
- 3 May 2024
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 121 (9) , 302
Correspondence
- 30 August 2021
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 112 (6) , e477-E477
Coronary Collateralization of a Tumor Located in the Aortopulmonary Window
- 30 August 2021
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 112 (6) , e477-E477
Coronary Collateralization of a Tumor Located in the Aortopulmonary Window
- Open Access
- 18 August 2020
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (5) , 536-545
Fluorescence In Situ Hybridization and Polymerase Chain Reaction to Detect Infections in Patients With Left Ventricular Assist Devices
The development of driveline infections following left ventricular assist device (LVAD) implantation remains a major problem. We investigated the impact of fluorescence in situ hybridization (FISH) combined with 16S rRNA gene sequencing on the diagnosis of driveline infections. LVAD drivelines (n = 61) from 60 consecutive patients were obtained during LVAD explantation and subjected to FISH analysis. 16S rRNA gene polymerase chain reaction (PCR) and sequencing to identify the microorganisms were performed. Results were compared with those of a standard microbiological culture. The reasons for pump removal were heart transplantation (n = 22), weaning (n = 14), pump exchange due to pump thrombosis (n = 12), technical problems (n = 7), or death (n = 5). Of the 60 patients, 26 exhibited clinical signs of a VAD-specific infection, while 34 (with 35 drivelines) showed no clinical signs of infection before explantation. The spectrum of identified pathogens differed between FISH/PCR and conventional microbiological diagnostics. In general, the bacterial spectrum was more diverse in FISH/PCR as compared with conventional microbiology, which more often showed only typical skin flora (coagulase-negative staphylococci and Corynebacteriaceae). In addition to identifying the species, FISH/PCR provided information about the spatial distribution and invasiveness of the microorganisms. Cultures usually represent the only source of microbiological information for clinicians and often prove to be unsatisfactory in complex LVAD cases. FISH/PCR not only identified a greater number and variety of microorganisms than standard culture did, but it also provided information about the number, localization, and biofilm state of the pathogens, making it a useful tool for diagnosing the specific cause of LVAD driveline infections.
- 18 August 2020
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (5) , 536-545
Open AccessFluorescence In Situ Hybridization and Polymerase Chain Reaction to Detect Infections in Patients With Left Ventricular Assist Devices
The development of driveline infections following left ventricular assist device (LVAD) implantation remains a major problem. We investigated the impact of fluorescence in situ hybridization (FISH) combined with 16S rRNA gene sequencing on the diagnosis of driveline infections. LVAD drivelines (n = 61) from 60 consecutive patients were obtained during LVAD explantation and subjected to FISH analysis. 16S rRNA gene polymerase chain reaction (PCR) and sequencing to identify the microorganisms were performed. Results were compared with those of a standard microbiological culture. The reasons for pump removal were heart transplantation (n = 22), weaning (n = 14), pump exchange due to pump thrombosis (n = 12), technical problems (n = 7), or death (n = 5). Of the 60 patients, 26 exhibited clinical signs of a VAD-specific infection, while 34 (with 35 drivelines) showed no clinical signs of infection before explantation. The spectrum of identified pathogens differed between FISH/PCR and conventional microbiological diagnostics. In general, the bacterial spectrum was more diverse in FISH/PCR as compared with conventional microbiology, which more often showed only typical skin flora (coagulase-negative staphylococci and Corynebacteriaceae). In addition to identifying the species, FISH/PCR provided information about the spatial distribution and invasiveness of the microorganisms. Cultures usually represent the only source of microbiological information for clinicians and often prove to be unsatisfactory in complex LVAD cases. FISH/PCR not only identified a greater number and variety of microorganisms than standard culture did, but it also provided information about the number, localization, and biofilm state of the pathogens, making it a useful tool for diagnosing the specific cause of LVAD driveline infections.