Yong Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yong Hu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Fanglong Yin
Beijing Key Laboratory of Advanced Manufacturing Technology, Beijing University of Technology, Beijing 100124, China
2 shared publications - Pengpeng He
China University of Geosciences
2 shared publications - Shuang Peng
School of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, China
2 shared publications Wei He
2 shared publicationsChengfang Wang
School of Transportation, Wuhan University of Technology, Wuhan, China
1 shared publicationFengyan Shi
Key Laboratory of High Performance of Ship Technology of Ministry of Education, Wuhan University of Technology, Wuhan, China
1 shared publication
Latest Publications
- 9 February 2025
- Published by Elsevier in Pattern Recognition
- Vol. 162
ICV-Net: An identity cost volume network for multi-view stereo depth inference
- 9 February 2025
- Published by Elsevier in Pattern Recognition
- Vol. 162
ICV-Net: An identity cost volume network for multi-view stereo depth inference
- 23 July 2024
- Published by Elsevier in Measurement
- Vol. 238
A vision measurement method for ship hull plates based on multi-view stereo and image segmentation
- 23 July 2024
- Published by Elsevier in Measurement
- Vol. 238
A vision measurement method for ship hull plates based on multi-view stereo and image segmentation
- Open Access
An Improved Zero-Flowrate Switching Control Method to Reduce Switching Losses in a Hydraulic Actuator
Hydraulic switching actuators are high-efficiency, fast response, and low-cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously, the authors proposed a zero-flowrate switching method to reduce the throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve the desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to the previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.
Open AccessAn Improved Zero-Flowrate Switching Control Method to Reduce Switching Losses in a Hydraulic Actuator
Hydraulic switching actuators are high-efficiency, fast response, and low-cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously, the authors proposed a zero-flowrate switching method to reduce the throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve the desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to the previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.
- Open Access
- 8 March 2024
- Published by MDPI AG in Preprints.org
An Improved Zero-Flowrate Switching Control Method to Reduce Switching Losses in a Hydraulic Actuator
—Hydraulic switching actuators are high efficiency, fast response, and low cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously the authors proposed a zero-flowrate switching method to reduce throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.
- 8 March 2024
- Published by MDPI AG in Preprints.org
Open AccessAn Improved Zero-Flowrate Switching Control Method to Reduce Switching Losses in a Hydraulic Actuator
—Hydraulic switching actuators are high efficiency, fast response, and low cost solutions for hydraulic control systems. One of the challenging problems is throttling losses during valve transitions. Previously the authors proposed a zero-flowrate switching method to reduce throttling energy loss of the switching valve, where a hydraulic resonator is applied to make the flowrates through the lines approaching zero before the valves are switched off. The major challenge of this approach is fast switching valves whose transition times are less than 2 ms. In this paper, an improved zero-flowrate switching method is presented. It utilizes the capacity with independent inlet/outlet ports to regulate flowrates through the lines. Models of capacity applied in a simple line with different pressure signals are developed to explore characteristics of the capacity, based on which a complete actuation system is developed. In the complete model, resistance and inductance are optimized to achieve desired flowrate response. The improved zero-flowrate switching method reduces throttling energy losses by 99.945% compared to a hard switching system. The simulation results demonstrated that the improved zero-flowrate switching method performs as expected in the design condition. A capacity with proper volume is able to regulate flowrates through all the lines to zero, with the help of appropriate resistance and inductance. Compared to previous zero-flowrate switching method, the novel strategy allows slower switching valves applied in hydraulic actuation systems and achieves better efficiency performance. This research paves a new avenue for reducing throttling energy losses and improves system efficiency in hydraulic switching actuators, as well as most of the hydraulic switch-mode circuits.
- 27 January 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 130 (11-12) , 5853-5867
Springback ratio matrix-based description and compensation for precision forming of doubly curved plates using reconfigurable dies
- 27 January 2024
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 130 (11-12) , 5853-5867
Springback ratio matrix-based description and compensation for precision forming of doubly curved plates using reconfigurable dies
- 3 February 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (1-2) , 669-689
Research on the axial elongation and springback law of thick-walled tubes in cold bending forming
- 3 February 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (1-2) , 669-689
Research on the axial elongation and springback law of thick-walled tubes in cold bending forming
- 1 April 2020
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 35 (2) , 407-410
Dimpling Suppression by Chamfered Rotatable Cubic Punch in Reconfigurable Die Forming
- 1 April 2020
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 35 (2) , 407-410
Dimpling Suppression by Chamfered Rotatable Cubic Punch in Reconfigurable Die Forming