Jimmy Roberto Vaca González
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jimmy Roberto Vaca González has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Quinatoa
Universidad Técnica de Cotopaxi
2 shared publications - Byron P. Corrales
Universidad Técnica de Cotopaxi
1 shared publication - Jaime Guamangallo
Dirección de Posgrados, Facultad de Ciencias de la Ingeniería y Aplicadas, Universidad Técnica de Cotopaxi, Latacunga 050150, Ecuador
1 shared publication - Jefferson Alberto Porras Reyes
Universidad Técnica de Cotopaxi
1 shared publication - Josue Ortiz
Universidad Técnica de Cotopaxi
1 shared publication - Luis Camacho
Facultad de Ciencias de la Ingeniera y Aplicadas, Universidad Tcnica de Cotopaxi, Latacunga, Ecuador
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Polo de Capacitacion, Investigacion y Publicacion in Polo del Conocimiento
- Vol. 11 (6) , 4693-4714
Análisis de la distorsión armónica en una red de distribución eléctrica para proponer estrategias de mitigación y mejora
La presente investigación analiza la distorsión armónica en una red de distribución radial de baja tensión dominada por cargas no lineales, con el objetivo de proponer estrategias de mitigación y mejora mediante modelación numérica y simulación computacional, sin mediciones físicas. Se modeló un alimentador representativo que suministra a rectificadores de seis pulsos y cargas electrónicas monofásicas; la forma de onda de corriente distorsionada se descompuso mediante la Transformada Rápida de Fourier (FFT) para obtener su espectro armónico, y la distorsión armónica total (THD) se evaluó frente a los límites de la norma IEEE 519-2022. El caso base arrojó una distorsión de corriente de THDi = 32,8% y una distorsión de tensión en el punto de acoplamiento común de THDv = 5,4%, superando los límites normativos, con los armónicos de orden 3.º, 5.º y 7.º como componentes dominantes. Como estrategia de mitigación se diseñó y simuló un banco de filtros pasivos sintonizados, que redujo la THDi a 4,3% y la THDv a 1,3%, ambas por debajo del límite del 5%. Se concluye que el análisis computacional constituye una herramienta eficaz para diagnosticar la contaminación armónica y dimensionar medidas de mitigación que restauran la calidad de la energía en las redes de distribución.
- 1 June 2026
- Published by Polo de Capacitacion, Investigacion y Publicacion in Polo del Conocimiento
- Vol. 11 (6) , 4693-4714
Open AccessAnálisis de la distorsión armónica en una red de distribución eléctrica para proponer estrategias de mitigación y mejora
La presente investigación analiza la distorsión armónica en una red de distribución radial de baja tensión dominada por cargas no lineales, con el objetivo de proponer estrategias de mitigación y mejora mediante modelación numérica y simulación computacional, sin mediciones físicas. Se modeló un alimentador representativo que suministra a rectificadores de seis pulsos y cargas electrónicas monofásicas; la forma de onda de corriente distorsionada se descompuso mediante la Transformada Rápida de Fourier (FFT) para obtener su espectro armónico, y la distorsión armónica total (THD) se evaluó frente a los límites de la norma IEEE 519-2022. El caso base arrojó una distorsión de corriente de THDi = 32,8% y una distorsión de tensión en el punto de acoplamiento común de THDv = 5,4%, superando los límites normativos, con los armónicos de orden 3.º, 5.º y 7.º como componentes dominantes. Como estrategia de mitigación se diseñó y simuló un banco de filtros pasivos sintonizados, que redujo la THDi a 4,3% y la THDv a 1,3%, ambas por debajo del límite del 5%. Se concluye que el análisis computacional constituye una herramienta eficaz para diagnosticar la contaminación armónica y dimensionar medidas de mitigación que restauran la calidad de la energía en las redes de distribución.
- Open Access
- 18 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 77 (1) , 24
Optimal Sizing of Hybrid Generation Systems (Photovoltaic System and Energy Storage System) for Off-Grid Applications
This paper presents an optimal sizing strategy for a hybrid generation system combining photovoltaic (PV) and energy storage systems. To achieve this, the optimization problem is solved using the simplex method for linear programming, implemented through Python. The model considers test data on electrical energy demand and solar irradiation, alongside battery operating conditions such as state of charge (SOC) and upper and lower charge limits as key decision variables. Conventional PV system sizing serves as a benchmark to assess the effectiveness of the optimization, with particular attention given to the computational resources required for problem solving.The results obtained from the optimization method demonstrate a substantial improvement in the utilization of energy resources, both from the photovoltaic system and the energy storage system. This approach enabled the design of an optimized system based on the proposed model, which was further refined using Matlab/Simulink.
- 18 November 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 77 (1) , 24
Open AccessOptimal Sizing of Hybrid Generation Systems (Photovoltaic System and Energy Storage System) for Off-Grid Applications
This paper presents an optimal sizing strategy for a hybrid generation system combining photovoltaic (PV) and energy storage systems. To achieve this, the optimization problem is solved using the simplex method for linear programming, implemented through Python. The model considers test data on electrical energy demand and solar irradiation, alongside battery operating conditions such as state of charge (SOC) and upper and lower charge limits as key decision variables. Conventional PV system sizing serves as a benchmark to assess the effectiveness of the optimization, with particular attention given to the computational resources required for problem solving.The results obtained from the optimization method demonstrate a substantial improvement in the utilization of energy resources, both from the photovoltaic system and the energy storage system. This approach enabled the design of an optimized system based on the proposed model, which was further refined using Matlab/Simulink.
- Open Access
- 23 July 2024
- Published by Instituto Superior Tecnologico Ruminahui in Revista Conectividad
- Vol. 5 (3) , 62-78
Evaluación de modelos de optimización convexos para minimizar pérdidas en el sistema de distribución
El presente trabajo de investigación propone la evaluación de modelos convexos para el despacho de energía a corto plazo, optimizando la ubicación de generadores y minimizando pérdidas en redes de distribución. Para ello, se utiliza modelos convexos en un periodo de 12 horas con una variación horaria de la demanda, empleando el sistema IEEE de 15 nodos tipo radial. Debido a las ecuaciones de potencia activa y reactiva de inyección nodal, el problema se vuelve no convexo y requiere más recursos computacionales para encontrar soluciones locales óptimas. Para abordar el problema de no linealidad se analizan modelos como el cálculo de Wirtinger y la aproximación cónica de segundo orden. El primer modelo resuelve en 8.12 segundos con errores de voltaje del 0.63% y ángulo del 1.40%, y el segundo en 17.8 segundos con errores del 0.61% y 1.38%, respectivamente. La ubicación óptima de las unidades de generación son los nodos 7, 8 y 10. El valor de la función objetivo para cada modelo es 0.00731149 p.u. para el modelo no lineal, 0.00734619 p.u, para el modelo Wirtinger 0.00744715 p.u, y para el modelo de aproximación cónica de segundo orden (SOC), con una base de 100 kVA.
- 23 July 2024
- Published by Instituto Superior Tecnologico Ruminahui in Revista Conectividad
- Vol. 5 (3) , 62-78
Open AccessEvaluación de modelos de optimización convexos para minimizar pérdidas en el sistema de distribución
El presente trabajo de investigación propone la evaluación de modelos convexos para el despacho de energía a corto plazo, optimizando la ubicación de generadores y minimizando pérdidas en redes de distribución. Para ello, se utiliza modelos convexos en un periodo de 12 horas con una variación horaria de la demanda, empleando el sistema IEEE de 15 nodos tipo radial. Debido a las ecuaciones de potencia activa y reactiva de inyección nodal, el problema se vuelve no convexo y requiere más recursos computacionales para encontrar soluciones locales óptimas. Para abordar el problema de no linealidad se analizan modelos como el cálculo de Wirtinger y la aproximación cónica de segundo orden. El primer modelo resuelve en 8.12 segundos con errores de voltaje del 0.63% y ángulo del 1.40%, y el segundo en 17.8 segundos con errores del 0.61% y 1.38%, respectivamente. La ubicación óptima de las unidades de generación son los nodos 7, 8 y 10. El valor de la función objetivo para cada modelo es 0.00731149 p.u. para el modelo no lineal, 0.00734619 p.u, para el modelo Wirtinger 0.00744715 p.u, y para el modelo de aproximación cónica de segundo orden (SOC), con una base de 100 kVA.
- 12 March 2024
- Published by Springer Nature
- p. 71-80
Control System for a Cacao Drying Process: Case Study Cylindrical Dryer
- 12 March 2024
- Published by Springer Nature
- p. 71-80
Control System for a Cacao Drying Process: Case Study Cylindrical Dryer