Stefanie Rahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefanie Rahn has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hans-Ulrich Kauczor
University Hospital Heidelberg
2 shared publications - Thuy Duong Do
Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), University of Heidelberg, Im Neuenheimer Feld 420, 69120 Heidelberg, Germany
2 shared publications - Tim Frederik Weber
Clinic of Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
2 shared publications - Christopher Schuppert
Department of Diagnostic and Interventional Radiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
1 shared publication - Claudius Melzig
Klinik für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Heidelberg, Heidelberg, Deutschland
1 shared publication - Frank Bergner
Philips GmbH Innovative Technologies, 22335 Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 25 August 2025
- Published by MDPI AG in Tomography
- Vol. 11 (9) , 94
Performance of a Deep Learning Reconstruction Method on Clinical Chest–Abdomen–Pelvis Scans from a Dual-Layer Detector CT System
Objective: The objective of this study was to compare the performance and robustness of a deep learning reconstruction method against established alternatives for soft tissue CT image reconstruction. Materials and Methods: Images were generated from portal venous phase chest–abdomen–pelvis CT scans (n = 99) acquired on a dual-layer spectral detector CT using filtered back projection, iterative model reconstruction (IMR), and deep learning reconstruction (DLR) with three parameter settings, namely ‘standard’, ‘sharper’, and ‘smoother’. Experienced raters performed a quantitative assessment by considering attenuation stability and image noise levels in ten representative structures across all reconstruction methods, as well as a qualitative assessment using a four-point Likert scale (1 = poor, 2 = fair, 3 = good, 4 = excellent) for their overall perception of ‘smoother’ DLR and IMR images. One scan was excluded due to cachexia, which limited the quantitative measurements. Results: The inter-rater reliability for quantitative measurements ranged from moderate to excellent (r = 0.63–0.96). Attenuation values did not differ significantly between reconstruction methods except for DLR against IMR in the psoas muscle (mean + 3.0 HU, p < 0.001). Image noise levels differed significantly between reconstruction methods for all structures (all p < 0.001) and were lower than FBP with any DLR parameter setting. Image noise levels with ‘smoother’ DLR were predominantly lower than or equal to IMR, while they were higher with ‘standard’ DLR and ‘sharper’ DLR. The ‘smoother’ DLR images received a higher mean rating for overall image quality than the IMR images (3.7 vs. 2.3, p < 0.001). Conclusions: ‘Smoother’ DLR images were perceived by experienced readers as having improved quality compared to FBP and IMR while also exhibiting objectively lower or equivalent noise levels.
- 25 August 2025
- Published by MDPI AG in Tomography
- Vol. 11 (9) , 94
Open AccessPerformance of a Deep Learning Reconstruction Method on Clinical Chest–Abdomen–Pelvis Scans from a Dual-Layer Detector CT System
Objective: The objective of this study was to compare the performance and robustness of a deep learning reconstruction method against established alternatives for soft tissue CT image reconstruction. Materials and Methods: Images were generated from portal venous phase chest–abdomen–pelvis CT scans (n = 99) acquired on a dual-layer spectral detector CT using filtered back projection, iterative model reconstruction (IMR), and deep learning reconstruction (DLR) with three parameter settings, namely ‘standard’, ‘sharper’, and ‘smoother’. Experienced raters performed a quantitative assessment by considering attenuation stability and image noise levels in ten representative structures across all reconstruction methods, as well as a qualitative assessment using a four-point Likert scale (1 = poor, 2 = fair, 3 = good, 4 = excellent) for their overall perception of ‘smoother’ DLR and IMR images. One scan was excluded due to cachexia, which limited the quantitative measurements. Results: The inter-rater reliability for quantitative measurements ranged from moderate to excellent (r = 0.63–0.96). Attenuation values did not differ significantly between reconstruction methods except for DLR against IMR in the psoas muscle (mean + 3.0 HU, p < 0.001). Image noise levels differed significantly between reconstruction methods for all structures (all p < 0.001) and were lower than FBP with any DLR parameter setting. Image noise levels with ‘smoother’ DLR were predominantly lower than or equal to IMR, while they were higher with ‘standard’ DLR and ‘sharper’ DLR. The ‘smoother’ DLR images received a higher mean rating for overall image quality than the IMR images (3.7 vs. 2.3, p < 0.001). Conclusions: ‘Smoother’ DLR images were perceived by experienced readers as having improved quality compared to FBP and IMR while also exhibiting objectively lower or equivalent noise levels.
- Open Access
Calcium-Based Imaging of the Spine at Dual-Layer CT and Evaluation of Vertebral Fractures in Multiple Myeloma
Purpose: To evaluate the prediction of vertebral fractures in plasma cell dyscrasias using dual-layer CT (DLCT) with quantitative assessment of conventional CT image data (CI), calcium suppressed image data (CaSupp), and calculation of virtual calcium-only (VCa) image data. Material and Methods: Patients (n = 81) with the diagnosis of a plasma cell dyscrasia and whole-body DLCT at the time of diagnosis and follow-up were retrospectively enrolled. CI, CaSupp25, and CaSupp100 were quantitatively analyzed using regions of interest in the lumbar vertebral bodies and fractured vertebral bodies on baseline or follow-up imaging. VCa were calculated by subtraction (CaSupp100-CaSupp25), delineating bone only. Logistic regression analyses were performed to assess the possibility of imminent spine fractures. Results: In 24 patients, new vertebral fractures were observed in the follow-up imaging. The possibility of new vertebral fractures was significant for baseline assessment of CT numbers in CI, CaSupp25, and VCa (p = 0.01, respectively), with a higher risk for new fractures in the case of lower CT numbers in CI (Odds ratio = [0.969; 0.994]) and VCa (Odds ratio = [0.978; 0.995]) and in the case of higher CT numbers in CaSupp 25 (Odds ratio 1.015 [1.006; 1.026]). Direct model comparisons implied that CT numbers in CaSupp 25 and VCa might show better fracture prediction than those in CI (R2 = 0.18 both vs. 0.15; AICc = 91.95, 91.79 vs. 93.62), suggesting cut-off values for CI at 103 HU (sensitivity: 54.2%; specificity: 82.5; AUC: 0.69), for VCa at 129 HU (sensitivity: 41.7%; specificity: 94.7; AUC: 0.72). Conclusions: Quantitative assessment with CaSupp and calculation of VCa is feasible to predict the vertebral fracture risk in MM patients. DLCT may prove useful in detecting imminent fractures.
Open AccessCalcium-Based Imaging of the Spine at Dual-Layer CT and Evaluation of Vertebral Fractures in Multiple Myeloma
Purpose: To evaluate the prediction of vertebral fractures in plasma cell dyscrasias using dual-layer CT (DLCT) with quantitative assessment of conventional CT image data (CI), calcium suppressed image data (CaSupp), and calculation of virtual calcium-only (VCa) image data. Material and Methods: Patients (n = 81) with the diagnosis of a plasma cell dyscrasia and whole-body DLCT at the time of diagnosis and follow-up were retrospectively enrolled. CI, CaSupp25, and CaSupp100 were quantitatively analyzed using regions of interest in the lumbar vertebral bodies and fractured vertebral bodies on baseline or follow-up imaging. VCa were calculated by subtraction (CaSupp100-CaSupp25), delineating bone only. Logistic regression analyses were performed to assess the possibility of imminent spine fractures. Results: In 24 patients, new vertebral fractures were observed in the follow-up imaging. The possibility of new vertebral fractures was significant for baseline assessment of CT numbers in CI, CaSupp25, and VCa (p = 0.01, respectively), with a higher risk for new fractures in the case of lower CT numbers in CI (Odds ratio = [0.969; 0.994]) and VCa (Odds ratio = [0.978; 0.995]) and in the case of higher CT numbers in CaSupp 25 (Odds ratio 1.015 [1.006; 1.026]). Direct model comparisons implied that CT numbers in CaSupp 25 and VCa might show better fracture prediction than those in CI (R2 = 0.18 both vs. 0.15; AICc = 91.95, 91.79 vs. 93.62), suggesting cut-off values for CI at 103 HU (sensitivity: 54.2%; specificity: 82.5; AUC: 0.69), for VCa at 129 HU (sensitivity: 41.7%; specificity: 94.7; AUC: 0.72). Conclusions: Quantitative assessment with CaSupp and calculation of VCa is feasible to predict the vertebral fracture risk in MM patients. DLCT may prove useful in detecting imminent fractures.