JMJohn Molloy

John Molloy

*This is an algorithmically generated author record based on publicly available information.

John Molloy has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Certification of 3180 series Standard Reference Materials® anions in solution

    by Brian E Lang, Thomas W Vetter, John L Molloy, Antonio Possolo

    The 3180 series Standard Reference Materials (SRMs) are single anion solutions intended for use as primary calibration standards for the quantitative determination of a single anion and are a key link in the traceability chain for analysis measurements of those anions made worldwide. The mass fraction of the anions in these materials are traceable to the International System of Units (SI). The 3180 series SRMs are calibration standards gravimetrically prepared from carefully assayed, high-purity materials dissolved in a water-based matrix with nominal mass fractions of 1 mg/g. The certified values and expanded uncertainties of these SRMs are determined by combining a gravimetric preparation value and a carefully measured ion chromatography instrumental value, taking their associated uncertainties into account. Over the course of its shelf life, an anion solution standard undergoes stability testing to monitor the continued validity of its certified value. Currently, NIST offers seven anion standard solutions: bromide, chloride, fluoride, iodide, nitrate, phosphate, and sulfate. New lots of these SRMs are produced continuously to meet demand and certificates of analysis are issued for each new lot to accurately reflect the anion mass fraction and associated uncertainty.

  • Certification of standard reference material® 1641f mercury in water

    by Colleen Bryan Sallee, Therese Butler, Jenna Klingsick, John Molloy, James Yen

    Standard Reference Material (SRM) 1641f Mercury in Water is intended for the calibration of instruments and techniques used for the determination of mercury in natural waters. It is designed for the preparation of calibration solutions and for use as a “spike” sample in a “method-of-additions” analytical procedure. A unit of SRM 1641f consists of ten ampoules, each ampoule containing approximately 10 mL of solution consisting of a trace amount of mercury in approximately 3% mass fraction nitric acid and 2% mass fraction hydrochloric acid. This publication documents the production, analytical methods, and computations involved in characterizing this product.

  • NIST’s engagement with CCQM studies from 1992 to 2023 :

    by David L Duewer, Christina E Cecelski, Megan H Cleveland, Nancy J Lin, Katrice A Lippa, Jacqueline L Mann, John L Molloy, Michael A Nelson, James E Norris, Kenneth W Pratt, et al.

    This report documents the engagement and measurement performance of the National Institute of Standards and Technology (NIST) in studies coordinated by the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) from1992 to 2023. The data and graphical tools used to document performance are part of the CCQM_Retrospectoscope analysis system, https://doi.org/10.18434/mds2-2952.