DBDexter Felix Brown

Dexter Felix Brown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dexter Felix Brown has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Model Predictive Control with a PSO Modelling Approach for Position Control of a Compliant Ankle Rehabilitation Robot

    by Dexter Felix Brown, Sheng Quan Xie, Yiliu Tu

    The Compliant Ankle Rehabilitation Robot (CARR) is actuated by four Pneumatic Artificial Muscles (PAMs). These actuators mimic biological muscles, making them highly applicable in robotic systems designed to apply guiding motion to a human joint, but have complex nonlinear dynamic properties making accurate tracking control difficult. This paper presents intelligent modelling and control methods to improve the CARR’s function in a rehabilitation setting. Using the Particle Swarm Optimisation (PSO) algorithm, dynamic models of the actuators are calculated. Two model setups are proposed, a single model and dual model. Model Predictive Control (MPC) was then implemented using these models and experimentally compared with Proportional Integral Derivative (PID) and Iterative Learning Control (ILC). The results showed that PID control was less accurate than the developed control schemes, with evidence of significant chattering, as well as both over- and undershooting the setpoint. ILC performed accurately, but the required learning period and some evidence of overfitting impacted the overall performance. Single-model MPC had low error values on the X axis of the CARR and maintained the most consistent 0 displacement when an axis was intended to stay motionless. Dual-model MPC had the lowest error values on the Y axis, the smoothest motion with the least chattering, and the best performance when both axes were in motion, but showed evidence of overshooting. Based on these results, both MPC implementations have proven to be successful and suitable for future work, and the PSO modelling method is able to produce suitably accurate models for the application.

  • Open Access

    Model Predictive Control with Optimal Modelling for Pneumatic Artificial Muscle in Rehabilitation Robotics: Confirmation of Validity Though Preliminary Testing

    by Dexter Felix Brown, Sheng Quan Xie

    This paper presents a model predictive controller (MPC) based on dynamic models generated using the Particle Swarm Optimisation method for accurate motion control of a pneumatic artificial muscle (PAM) for application in rehabilitation robotics. The physical compliance and lightweight nature of PAMs make them desirable for use in the field but also introduce nonlinear dynamic properties which are difficult to accurately model and control. As well as the MPC, three other control systems were examined for a comparative study: a particle-swarm optimised proportional-integral-derivative controller (PSO-PID), an iterative learning controller (ILC), and classical PID control. A series of different waveforms were used as setpoints for each controller, including addition of external loading and simulated disturbance, for a system consisting of a single PAM. Based on the displacement error measured for each experiment, the PID controller performed worst with the largest error values and an issue with oscillating about the setpoint. PSO-PID performed better but still poorly compared with the other intelligent controllers, as well as still exhibiting oscillation, which is undesirable in any human–robot interaction as it can heavily impact the comfort and safety of the system. ILC performed well with rapid convergence to steady-state and low-error values, as well as mitigation of loads and disturbance; however, it performed poorly under changing frequency of input. MPC generally performed the best of the controllers tested here, with the lowest error values and a rapid response to changes in setpoint, as well as no required learning period due to the predictive algorithm.


  • Open Access

    A Piecewise Particle Swarm Optimisation Modelling Method for Pneumatic Artificial Muscle Actuators

    by Dexter Felix Brown, Sheng Quan Xie

    Pneumatic artificial muscles (PAMs) possess compliant properties desirable for certain applications such as prosthetics and robotic structures. However, this compliance along with their inherent nonlinear dynamics make them difficult to accurately model and as such accurately control under certain control architectures. Common approaches to this problem include measuring the actuator’s physical properties and approximating a model based on these parameters or using deep learning methods to train a model with the actuator’s behaviours. This paper introduces an optimisation-based modelling approach based on a particle swarm optimisation (PSO) algorithm using a mass–spring–damper approximation for the PAM, as well as a piecewise modelling method that accounts for nonlinear dynamics. The use of optimisation to estimate model parameters removes the need to measure physical properties, and the three-element approximation allows for fast model generation with low computational complexity and training data requirements. Through multiple tests comparing model behaviour with real PAM motion, the accuracy of these models is confirmed to be promising for future work. Dynamic nonlinearities are properly accounted for using the piecewise modelling method, including both hysteresis and disproportionate input/output relationship across the stroke length of the actuator. Compared with other PAM modelling techniques, this method has improved generation time, lower computational load requirements, and complexity and can be applied to actuators for which the phenomenological mass–spring–damper model is a good approximation.


  • Open Access

    Effectiveness of Intelligent Control Strategies in Robot-Assisted Rehabilitation—A Systematic Review

    by Dexter Felix Brown, Sheng Quan Xie

    This review aims to provide a systematic analysis of the literature focused on the use of intelligent control systems in robotics for physical rehabilitation, identifying trends in recent research and comparing the effectiveness of intelligence used in control, with the aim of determining important factors in robot-assisted rehabilitation and how intelligent controller design can improve them. Seven electronic research databases were searched for articles published in the years 2015 – 2022 with articles selected based on relevance to the subject area of intelligent control systems in rehabilitation robotics. It was found that the most common use of intelligent algorithms for control is improving traditional control strategies with optimization and learning techniques. Intelligent algorithms are also commonly used in sensor output mapping, model construction, and for various data learning purposes. Experimental results show that intelligent controllers consistently outperform non-intelligent controllers in terms of transparency, tracking accuracy, and adaptability. Active participation of the patients and lowered interaction forces are consistently mentioned as important factors in improving the rehabilitation outcome as well as the patient experience. However, there are limited examples of studies presenting experimental results with impaired participants suffering limited range of motion, so the effectiveness of therapy provided by these systems is often difficult to quantify. A lack of universal evaluation criteria also makes it difficult to compare control systems outside of articles which use their own comparison criteria.