Fu-Yan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fu-Yan Liu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Peng Kuang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
3 shared publications B.Y. Wang
2 shared publicationsBaoyi Wang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publications- Baoyi Wang
Institute of High Energy Physics Chinese Academy of Sciences 100049 Beijing China
2 shared publications H.Q. Zhang
2 shared publicationsHongqiang Zhang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 1 November 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3149 (1)
Structural Optimization of the Main Buncher for Pulsed Slow Positron Beam System in IHEP
Slow positron lifetime measurement is highly valuable for characterizing the vacancy-type defects with depth profile in metals, semi-conductors and polymers. Benefited from the pulsed system, the timing resolution for slow positrons can be enhanced to hundreds ps. As the core component of this system, the main buncher’s structural stability was investigated through simulations in this study. Based on the results, a compacted PTFE support ring is implemented to the inner tube, effectively suppressing performance degradation caused by inner cylinder inclination. These optimizations provide a critical foundation for the development of high-performance bunchers and open a clear pathway toward advanced pulsing systems.
- 1 November 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3149 (1)
Open AccessStructural Optimization of the Main Buncher for Pulsed Slow Positron Beam System in IHEP
Slow positron lifetime measurement is highly valuable for characterizing the vacancy-type defects with depth profile in metals, semi-conductors and polymers. Benefited from the pulsed system, the timing resolution for slow positrons can be enhanced to hundreds ps. As the core component of this system, the main buncher’s structural stability was investigated through simulations in this study. Based on the results, a compacted PTFE support ring is implemented to the inner tube, effectively suppressing performance degradation caused by inner cylinder inclination. These optimizations provide a critical foundation for the development of high-performance bunchers and open a clear pathway toward advanced pulsing systems.
- 26 May 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 695-702
Research on reflective chopping technology for pulsed slow positron beam
- 26 May 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 695-702
Research on reflective chopping technology for pulsed slow positron beam
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Single-pixel positron beam diagnosis via compressive sampling
The morphology is a crucial indicator for diagnosing a low-energy, low-brightness particle beam. However, conventional positron beam diagnosis, based on the pixel scanning principle, is limited by physical constraints, such as the resolution of detector pixels. Here, we have presented a novel slow positron diagnosis method using compressive sampling. With a 100 × 100 pixel-sized mask, for example, the positron beam morphology can be significantly reconstructed with a peak signal-to-noise ratio of ∼40 dB, even at half the sampling rate compared to pixel scanning. It explores a promising approach for positron beam diagnosis with an ultra-high resolution and fast sampling rates.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Single-pixel positron beam diagnosis via compressive sampling
The morphology is a crucial indicator for diagnosing a low-energy, low-brightness particle beam. However, conventional positron beam diagnosis, based on the pixel scanning principle, is limited by physical constraints, such as the resolution of detector pixels. Here, we have presented a novel slow positron diagnosis method using compressive sampling. With a 100 × 100 pixel-sized mask, for example, the positron beam morphology can be significantly reconstructed with a peak signal-to-noise ratio of ∼40 dB, even at half the sampling rate compared to pixel scanning. It explores a promising approach for positron beam diagnosis with an ultra-high resolution and fast sampling rates.
- 29 July 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 212, 111459
Investigating the properties of ortho-positronium in liquid scintillators under oxygen quenching
- 29 July 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 212, 111459
Investigating the properties of ortho-positronium in liquid scintillators under oxygen quenching
- Open Access
Effect of Vacancy Behavior on Precipitate Formation in a Reduced-Activation V−Cr−Mn Medium-Entropy Alloy
In this work, we studied the evolution of vacancy-like defects and the formation of brittle precipitates in a reduced-activation V−Cr−Mn medium-entropy alloy. The evolution of local electronic circumstances around Cr and Mn enrichments, the vacancy defects, and the CrMn3 precipitates were characterized by using scanning electron microscopy with energy-dispersive spectroscopy, X-ray diffraction, and positron annihilation spectroscopy. The microstructure measurements showed that the Mn and Cr enrichments in the as-cast sample significantly evolved with temperature, i.e., from 400 °C, the Cr/Mn-segregated regions gradually dissolved into the matrix and then disappeared, and from 900 °C to 1000 °C, they existed as CrMn3 precipitates. The crystallite size of the phase corresponding to CrMn3 precipitates was about 29.4 nm at 900 °C and 43.7 nm at 1000 °C. The positron annihilation lifetime results demonstrated that the vacancies mediated the migration of Cr and Mn, and Cr and Mn segregation finally led to the formation of CrMn3 precipitates. The coincidence Doppler broadening results showed that the characteristic peak moved to the low-momentum direction, due to an increase in the size of the vacancy defects at the interface and the formation of CrMn3 precipitates.
Open AccessEffect of Vacancy Behavior on Precipitate Formation in a Reduced-Activation V−Cr−Mn Medium-Entropy Alloy
In this work, we studied the evolution of vacancy-like defects and the formation of brittle precipitates in a reduced-activation V−Cr−Mn medium-entropy alloy. The evolution of local electronic circumstances around Cr and Mn enrichments, the vacancy defects, and the CrMn3 precipitates were characterized by using scanning electron microscopy with energy-dispersive spectroscopy, X-ray diffraction, and positron annihilation spectroscopy. The microstructure measurements showed that the Mn and Cr enrichments in the as-cast sample significantly evolved with temperature, i.e., from 400 °C, the Cr/Mn-segregated regions gradually dissolved into the matrix and then disappeared, and from 900 °C to 1000 °C, they existed as CrMn3 precipitates. The crystallite size of the phase corresponding to CrMn3 precipitates was about 29.4 nm at 900 °C and 43.7 nm at 1000 °C. The positron annihilation lifetime results demonstrated that the vacancies mediated the migration of Cr and Mn, and Cr and Mn segregation finally led to the formation of CrMn3 precipitates. The coincidence Doppler broadening results showed that the characteristic peak moved to the low-momentum direction, due to an increase in the size of the vacancy defects at the interface and the formation of CrMn3 precipitates.