CMChloe Miller

Chloe Miller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chloe Miller has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Age‐Related Decreases in Colonic Neurokinin A Content and Release Monitored Using Electrochemical Immunosensors

    by Chloe Miller, Mark Yeoman, Bhavik Anil Patel

    Background: Aging increases the risk of bowel dysfunction and reduced quality of life. Although Neurokinin A (NKA)‐mediated smooth muscle contraction declines with age, it is unclear whether this reflects altered NKA content and/or release. This study examined age‐related changes in colonic NKA content and release and assessed whether changes correlated with fecal NKA. Methods: An electrochemical immunosensor was developed and characterized for NKA detection. Distal colon tissue and fecal pellets were collected from 5‐ and 22‐month‐old female C57BL6J mice. Basal and mechanically evoked tissue NKA release was recorded in the presence and absence of ondansetron. NKA content in tissue and fecal pellets were measured. Results: Sensor fabrication was validated by electrochemical and EDX analyses. The immunosensor detected NKA with a detection limit of 2.76 pM and high selectivity. Basal and mechanically evoked NKA release were significantly reduced with age. Ondansetron inhibited mechanically stimulated NKA release in 5‐month‐old but not 22‐month‐old colons. Tissue NKA content declined with age. The proportion of total NKA released decreased from 65% ± 22% in young tissue to 30% ± 23% in aged tissue. Fecal NKA levels were similarly reduced in older mice. Conclusions: Reduced NKA release with aging is associated with lower tissue content. The electrochemical immunosensor provides a simple, cost‐effective method for NKA quantification and could be adapted for other gastrointestinal neuropeptides. The decrease in fecal NKA levels supports further investigation of fecal NKA as a noninvasive marker of age‐related changes in bowel function.

  • Voltammetry Zoo: A 3D-Printed Electrode Laboratory Activity for Teaching Electrochemistry in Secondary Education

    by Diva B. Patel, Rora Whisby, Joshua Leonard, Ricoveer S. Shergill, Oliver Keattch, Chloe L. Miller, Bhavik A. Patel

    Electrochemistry is often perceived as a conceptually challenging topic, particularly at the secondary school level, due to the abstract nature of processes occurring at the electrode–solution interface. To address this, we present the “Voltammetry Zoo”, an inquiry-based laboratory activity that uses low-cost, 3D-printed animal-shaped electrodes to introduce key electrochemical concepts in an engaging and accessible manner. Electrodes fabricated from carbon black–polylactic acid (CB/PLA) were designed to have a similar surface area but differing geometries, enabling students to investigate how electrode shape influences electrochemical response using cyclic voltammetry of ferrocenemethanol. Students compare current responses across different electrode designs, encouraging hypothesis-driven learning and the exploration of structure–function relationships. Experimental results show a strong positive correlation between anodic peak current and electrode perimeter, while peak-to-peak separation remains independent of geometry. Additional activities, including scan rate analysis and copper electrodeposition, provide visual and quantitative insights into diffusion-controlled processes and electroactive surface regions. Classroom implementation with secondary school students demonstrated high levels of engagement and accessibility, although conceptual understanding of voltammetry varied, highlighting opportunities for further instructional scaffolding. Overall, this activity integrates digital fabrication, visualization, and electrochemical analysis to support student understanding of mass transport, electron transfer, and the influence of electrode design on analytical signals.

  • Open Access

    Development of a High-Sensitivity Electrochemical Immunoassay Using a Fully 3D-Printed Electrocatalytic Microelectrode Probe Platform

    by Niamh Docherty, Chloe L. Miller, Alexandra Dobrea, Daniel Macdonald, Alisdair Gordon, Susan Pang, Ying Fu, Melanie Jimenez, Damion K. Corrigan, Bhavik Anil Patel

    Electrochemical biosensors are a promising route to point-of-care diagnostics, yet their translation is hindered by the need for electrode surface functionalization, which introduces variability, increases cost and production complexity, and limits scalability and stability. Additive manufacturing using conductive filaments for rapid fabrication of three-dimensional (3D) electrodes overcomes these limitations. This study evaluates composite filaments comprising polylactic acid (PLA), carbon black (CB), and multiwalled carbon nanotubes (MWCNTs) for fused filament fabrication (FFF) of electrochemical electrodes for indirect detection via TMB+ measurement. Both the filament composition and electrode size were directly compared to determine the most suitable electrode architecture for sensitive measurements in complex samples. As a key novelty, the electrode diameter was reduced from 1 mm to the microscale to investigate the influence of electrode size on electron transfer efficiency. To improve measurement consistency and throughput, a 3D-printed assay accessory ("The Consistent Dipper") was developed to guide electrode immersion and reduce movement during amperometric measurements. PLA/MWCNT microelectrodes exhibited increased current density and reduced background noise compared to carbon black filament electrodes. The MWCNT microelectrodes were subsequently applied to a cardiac troponin I (cTnI) electrochemical immunoassay and in undiluted human serum, a cTnI detection limit of 7.4 pg mL-1 was achieved, representing an approximately 19-fold improvement compared to PLA/MWCNT macroelectrodes (140 pg mL-1). Following optimization to reduce incubation times, a clinically relevant detection limit of 85 pg mL-1 was obtained within a total assay time of 1 h. By combining enhanced electrochemical performance with low-cost, flexible FFF-printed microelectrodes, this platform provides a scalable route to rapid immunodiagnostics. This study represents the first application of microscale 3D-printed PLA/MWCNT electrodes for clinical biomarker detection using a readily manufacturable sensor system.


  • Open Access

    Improving Conductivity of Reduced Infill 3D‐Printed Electrodes Through Tuning Infill Pattern and Orientation

    by Rora Wisby, Ricoveer Singh Shergill, Chloe Miller, Bhavik Anil Patel

    3D printing has been shown to be a highly effective approach for the reproducible manufacturing of composite carbon electrodes. Various printing parameters have been effectively shown to enhance the electrochemical performance of 3D‐printed electrodes through reducing contact resistance; however, most of these studies have been conducted using 100% infill electrodes. Our study explored how the infill pattern and printing orientation can impact the electrochemical performance of reduced infill carbon black/polylactic acid (CB/PLA) electrodes. We printed 30% infill CB/PLA electrodes in linear, grid, triangle, and wiggle infill patterns in both horizontal and vertical orientations and evaluated the performance using cyclic voltammetry, conductivity imaging, and contact angle measurements. CB/PLA electrodes made using a grid infill pattern in horizontal orientation and a linear infill pattern with vertical orientation had the highest current and lowest difference between the anodic and cathodic peak potentials for an inner‐sphere redox probe. This study provides vital insight that the choice of infill pattern is important when printing in different orientations. The findings presented have significant implications on effective choice of printing parameters when crafting 3D‐printed electrodes and electronic components.


  • 3D-Printed Microelectrodes for Biological Measurement

    by Zehao Xue, Kanisha Patel, Paankhuri Bhatia, Chloe L. Miller, Ricoveer Singh Shergill, Bhavik Anil Patel

    Microelectrodes are useful electrochemical sensors that can provide spatial biological monitoring. Carbon fiber has been by far the most widely used microelectrode; however, a vast number of different materials and modification strategies have been developed to broaden the scope of microelectrodes. Carbon composite electrodes provide a simple approach to making microelectrodes with a wide range of materials, but manufacturing strategies are complex. 3D printing can provide the ability to make microelectrodes with high precision. We used fused filament fabrication to print single strands of carbon black/polylactic acid (CB/PLA) and multiwall carbon nanotube/polylactic acid (MWCNT/PLA), which were then made into microelectrodes. Microelectrodes ranged from 70 μm in diameter to 400 μm in diameter and were assessed using standard redox probes. MWCNT/PLA electrodes exhibited greater sensitivity, a lower limit of detection, and stability for the measurement of serotonin (5-HT). Both CB/PLA and MWCNT/PLA microelectrodes were able to monitor 5-HT overflow from the ex vivo ileum tissue. MWCNT/PLA microelectrodes were utilized to show differences in 5-HT overflow from ex vivo ileum and colon following exposure to odorants present in spices. These findings highlight that any conductive thermoplastic material can be fabricated into a microelectrode. This simple strategy can utilize a wide range of materials to make 3D-printed microelectrodes for a diverse range of applications.