Justin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Justin Kim has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Maria Wu
George Washington University School of Medicine and Health Sciences
3 shared publicationsRishika Bheem
George Washington University School of Medicine and Health Sciences
3 shared publicationsSasa Ivanovic
Yale School of Medicine
3 shared publicationsAriana Adnani
George Washington University School of Medicine and Health Sciences
2 shared publications- Brendan Sweeney
George Washington University School of Medicine and Health Sciences
2 shared publications Danielle Davison
George Washington University Medical Faculty Associates
2 shared publications
Latest Publications
- 10 February 2026
- Published by SAGE Publications in Journal of Intensive Care Medicine
Authors' Response to Letter to the Editor
- 10 February 2026
- Published by SAGE Publications in Journal of Intensive Care Medicine
Authors' Response to Letter to the Editor
- 5 September 2025
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 41 (4) , 344-351
Midline Catheters as an Alternative for Central Venous Catheters in Venous Pressure Monitoring: A Single Center Experience
Purpose: Midline catheters (ML) are long peripheral intravenous catheters placed in an upper extremity above the antecubital fossa via the basilic, cephalic, or brachial veins. These provide safe and comfortable long-term vascular access for critically ill patients. Central venous pressures (CVP) are obtained from central venous catheters (CVC) and are often used as resuscitation parameters. Given the proximity of ML to the axillary vein, we investigated if midline venous pressure (MVP) is comparable to CVP. Methods: This is an observational study conducted in adult critical care patients at a tertiary academic center. Inclusion criteria were patients with a CVC in the subclavian or internal jugular veins and a ML in place as part of standard ICU care. Pressure measurements were recorded from both catheters every 15 min over a 60-min period. Demographic, clinical, and physiological data points were collected. Continuous variables were analyzed using the t-test. Pearson correlation was used to evaluate the relationship between the paired variables. Results: We enrolled 50 patients with 5 pressure measurements taken per patient (n = 250). The mean MVP and CVP were 10.6 ± 6.4 mm Hg and 9.1 ± 6.3 mm Hg, respectively ( P < .001). In Bland Altman analysis, the mean bias was −1.48 ± 3.99 mm Hg with limits of agreement of −9.3 mm Hg to 6.3 mm Hg. The Pearson correlation coefficient was 0.8 ( P < .001). Conclusions: Our study investigated MVP as a correlate of CVP. Our results show a mean bias of −1.48 ± 3.99 mm Hg and a strong positive Pearson correlation coefficient of 0.8 between the MVP and the CVP. The large limits of agreement indicate MVP and CVP are not interchangeable. Despite this, clinically significant pressure values from CVCs and MLs trend similarly.
- 5 September 2025
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 41 (4) , 344-351
Midline Catheters as an Alternative for Central Venous Catheters in Venous Pressure Monitoring: A Single Center Experience
Purpose: Midline catheters (ML) are long peripheral intravenous catheters placed in an upper extremity above the antecubital fossa via the basilic, cephalic, or brachial veins. These provide safe and comfortable long-term vascular access for critically ill patients. Central venous pressures (CVP) are obtained from central venous catheters (CVC) and are often used as resuscitation parameters. Given the proximity of ML to the axillary vein, we investigated if midline venous pressure (MVP) is comparable to CVP. Methods: This is an observational study conducted in adult critical care patients at a tertiary academic center. Inclusion criteria were patients with a CVC in the subclavian or internal jugular veins and a ML in place as part of standard ICU care. Pressure measurements were recorded from both catheters every 15 min over a 60-min period. Demographic, clinical, and physiological data points were collected. Continuous variables were analyzed using the t-test. Pearson correlation was used to evaluate the relationship between the paired variables. Results: We enrolled 50 patients with 5 pressure measurements taken per patient (n = 250). The mean MVP and CVP were 10.6 ± 6.4 mm Hg and 9.1 ± 6.3 mm Hg, respectively ( P < .001). In Bland Altman analysis, the mean bias was −1.48 ± 3.99 mm Hg with limits of agreement of −9.3 mm Hg to 6.3 mm Hg. The Pearson correlation coefficient was 0.8 ( P < .001). Conclusions: Our study investigated MVP as a correlate of CVP. Our results show a mean bias of −1.48 ± 3.99 mm Hg and a strong positive Pearson correlation coefficient of 0.8 between the MVP and the CVP. The large limits of agreement indicate MVP and CVP are not interchangeable. Despite this, clinically significant pressure values from CVCs and MLs trend similarly.
- 23 July 2024
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 40 (1) , 47-53
Midline Catheters as an Alternative for Central Venous Catheters in Venous Oxygen Saturation Monitoring: A Single Center Experience
Background: Central venous oxygen saturation (ScvO2) obtained from a central venous catheter (CVC) is often used to approximate oxygen delivery in critically ill patients. Despite their importance in administering medications and monitoring oxygen delivery, the use of CVCs can be associated with significant complications. Midline catheters are inserted via a peripheral vein above the antecubital fossa and provide a safe alternative to CVCs. This study aimed to determine the equivalence of ScvO2 and midline catheter oxygen saturation (SmO2) in critically ill patients. Methods: This was a single-center observational study of critically ill adult patients who had concurrently placed CVCs (internal jugular and subclavian) and midline catheters as part of standard ICU care. Venous oxygen saturation and lactate levels were measured from both catheters using the Abbott point-of-care i-STAT analyzer. Demographic and ICU admission data were collected. Continuous variables were compared using the paired t-test. Pearson's correlation was used to evaluate the linear correlation between ScvO2 and SmO2. The systematic error (bias) was calculated using Bland-Altman analysis. Receiver operating characteristic curves were constructed to evaluate the sensitivities and specificities for different values of SmO2 to predict ScvO2. Results: Forty-eight patients (n = 48) were enrolled in the study. The mean ScvO2 and SmO2 were 65.5% +/- 11.2% and 62.7% +/- 17.6% respectively (p = 0.1197). In the Bland-Altman analysis, the mean bias between ScvO2 and SmO2 was 2.8% +/- 12.3% with 95% limits of agreement of −21.3% to 26.9%. More than 60% of the ScvO2 and SmO2 values diverged by ≥ 5%. Conclusions: The difference between the mean SmO2 and ScvO2 was not statistically significant and the mean bias between SmO2 and ScvO2 is low. Despite this, the substantially large standard deviation and limits of agreement preclude the use of SmO2 as a direct surrogate of ScvO2.
- 23 July 2024
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 40 (1) , 47-53
Midline Catheters as an Alternative for Central Venous Catheters in Venous Oxygen Saturation Monitoring: A Single Center Experience
Background: Central venous oxygen saturation (ScvO2) obtained from a central venous catheter (CVC) is often used to approximate oxygen delivery in critically ill patients. Despite their importance in administering medications and monitoring oxygen delivery, the use of CVCs can be associated with significant complications. Midline catheters are inserted via a peripheral vein above the antecubital fossa and provide a safe alternative to CVCs. This study aimed to determine the equivalence of ScvO2 and midline catheter oxygen saturation (SmO2) in critically ill patients. Methods: This was a single-center observational study of critically ill adult patients who had concurrently placed CVCs (internal jugular and subclavian) and midline catheters as part of standard ICU care. Venous oxygen saturation and lactate levels were measured from both catheters using the Abbott point-of-care i-STAT analyzer. Demographic and ICU admission data were collected. Continuous variables were compared using the paired t-test. Pearson's correlation was used to evaluate the linear correlation between ScvO2 and SmO2. The systematic error (bias) was calculated using Bland-Altman analysis. Receiver operating characteristic curves were constructed to evaluate the sensitivities and specificities for different values of SmO2 to predict ScvO2. Results: Forty-eight patients (n = 48) were enrolled in the study. The mean ScvO2 and SmO2 were 65.5% +/- 11.2% and 62.7% +/- 17.6% respectively (p = 0.1197). In the Bland-Altman analysis, the mean bias between ScvO2 and SmO2 was 2.8% +/- 12.3% with 95% limits of agreement of −21.3% to 26.9%. More than 60% of the ScvO2 and SmO2 values diverged by ≥ 5%. Conclusions: The difference between the mean SmO2 and ScvO2 was not statistically significant and the mean bias between SmO2 and ScvO2 is low. Despite this, the substantially large standard deviation and limits of agreement preclude the use of SmO2 as a direct surrogate of ScvO2.