Kalyan Kumar Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kalyan Kumar Das has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Koustuvmoni Bharadwaj
Mechanical Engineering Department, Assam Science and Technology University, Guwahati, India
2 shared publications - Krishna Bharadwaj
Agronomy Department, Assam Agricultural University - Zonal Research Station, Diphu, India
2 shared publications - Partha Protim Borthakur
Department of Mechanical Engineering, Dibrugarh University, Dibrugarh 786004, India
2 shared publications - Rupam Deka
Department of Mechanical Engineering, Dibrugarh University, Dibrugarh 786004, India
2 shared publications - Chinmoy Jit Sarma
Assam Energy Institute, Sivasagar, A Centre of Rajiv Gandhi Institute of Petroleum Technology, Sivasagar 785663, Assam, India
1 shared publication - Madhurjya Saikia
Department of Mechanical Engineering, Institute of Engineering and Technology, Dibrugarh University, Dibrugarh 786004, Assam, India
1 shared publication
Latest Publications
- 21 May 2026
- Published by Springer Nature
- p. 349-359
Numerical Investigation of the Influence of Roof Pitch on the Natural Ventilation Efficiency
- 21 May 2026
- Published by Springer Nature
- p. 349-359
Numerical Investigation of the Influence of Roof Pitch on the Natural Ventilation Efficiency
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Error Analysis in Detection of Soil Moisture Using Triad Spectroscopy Sensor
Soil moisture value is critical to the global hydrological cycle and impacts agriculture, environmental science, urban planning, forestry, and more. Traditional methods of measuring soil moisture, though well established, are time consuming, labor intensive, requires installation and maintenance of equipment, expensive and gives low resolution outputs. This calls for the requirement of a soil moisture calculation method which is instantaneous, portable, economic and efficient. Spectroscopy has emerged as a promising solution since it can deliver valuable insights into the composition, structure, and properties of materials across diverse fields. In this study, a spectroscopic sensor was employed to analyze soil samples, and its readings were compared with soil moisture values determined through the conventional gravimetric method. By applying different regression approaches, a relationship between the sensor output and soil moisture was established, aiming to minimize errors, such as mean absolute error (MAE), mean bias error (MBE), and root mean square error (RMSE). The findings revealed that a third-order polynomial regression equation at 705 nm wavelength provided the most accurate results, with error values of MAE, MBE, and RMSE being 0.38, 0.06, and 0.5, respectively. This outcome demonstrates that combining the spectroscopic sensor with the derived equation can offer an instantaneous, noncontact method for soil moisture estimation. Compared to the lengthy and labor-intensive gravimetric process, this approach provides a rapid and practical solution for soil moisture assessment in various applications.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Error Analysis in Detection of Soil Moisture Using Triad Spectroscopy Sensor
Soil moisture value is critical to the global hydrological cycle and impacts agriculture, environmental science, urban planning, forestry, and more. Traditional methods of measuring soil moisture, though well established, are time consuming, labor intensive, requires installation and maintenance of equipment, expensive and gives low resolution outputs. This calls for the requirement of a soil moisture calculation method which is instantaneous, portable, economic and efficient. Spectroscopy has emerged as a promising solution since it can deliver valuable insights into the composition, structure, and properties of materials across diverse fields. In this study, a spectroscopic sensor was employed to analyze soil samples, and its readings were compared with soil moisture values determined through the conventional gravimetric method. By applying different regression approaches, a relationship between the sensor output and soil moisture was established, aiming to minimize errors, such as mean absolute error (MAE), mean bias error (MBE), and root mean square error (RMSE). The findings revealed that a third-order polynomial regression equation at 705 nm wavelength provided the most accurate results, with error values of MAE, MBE, and RMSE being 0.38, 0.06, and 0.5, respectively. This outcome demonstrates that combining the spectroscopic sensor with the derived equation can offer an instantaneous, noncontact method for soil moisture estimation. Compared to the lengthy and labor-intensive gravimetric process, this approach provides a rapid and practical solution for soil moisture assessment in various applications.
- Open Access
- 29 December 2025
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- p. 10953-10965
CFD analysis of the impact of building shapes on the performance of wind-driven natural ventilation
The widespread use of natural ventilation in buildings is limited despite its numerous benefits, mainly due to the challenges associated with enhancing ventilation performance. This study employs numerical simulations to examine the influence of building shapes on ventilation performance in naturally ventilated building models. The wind-driven cross-ventilation through buildings with flat and pitched-roofs was investigated. Various building configurations were considered based on the position of openings in the building façades. To assess the natural ventilation efficiency of these configurations, numerical calculations were carried out to evaluate the normalised average velocity magnitude (V*), velocity homogeneity index (H), and air change rate (ACH). The results showed that a configuration with a windward opening near the ground and a leeward opening near the roof yielded the highest V* and H values for both flat and pitched-roof buildings. However, for the same configuration, V* and H were 17.69% and 13.24% higher in flat-roof buildings than in pitched-roof buildings. The highest ACH value in both flat-roof and pitched-roof buildings was obtained for the configuration with a windward opening at the mid-height of the building façade and a leeward opening near the ground. The ACH value for this configuration was 2.8% higher in flat-roof buildings than in pitched-roof buildings. These findings can support the design and optimisation of natural ventilation systems in buildings with improved ventilation performance.
- 29 December 2025
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- p. 10953-10965
Open AccessCFD analysis of the impact of building shapes on the performance of wind-driven natural ventilation
The widespread use of natural ventilation in buildings is limited despite its numerous benefits, mainly due to the challenges associated with enhancing ventilation performance. This study employs numerical simulations to examine the influence of building shapes on ventilation performance in naturally ventilated building models. The wind-driven cross-ventilation through buildings with flat and pitched-roofs was investigated. Various building configurations were considered based on the position of openings in the building façades. To assess the natural ventilation efficiency of these configurations, numerical calculations were carried out to evaluate the normalised average velocity magnitude (V*), velocity homogeneity index (H), and air change rate (ACH). The results showed that a configuration with a windward opening near the ground and a leeward opening near the roof yielded the highest V* and H values for both flat and pitched-roof buildings. However, for the same configuration, V* and H were 17.69% and 13.24% higher in flat-roof buildings than in pitched-roof buildings. The highest ACH value in both flat-roof and pitched-roof buildings was obtained for the configuration with a windward opening at the mid-height of the building façade and a leeward opening near the ground. The ACH value for this configuration was 2.8% higher in flat-roof buildings than in pitched-roof buildings. These findings can support the design and optimisation of natural ventilation systems in buildings with improved ventilation performance.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (8) , 1-4
Segregation of Municipal Solid Waste Based on Their Biodegradability Using Spectroscopy Sensor
The world today is facing a colossal increase in environmental pollution and degradation, resulting in ecological imbalance due to urbanization and development of smart cities. This necessitates the requirement for a robust waste management system, which can properly segregate waste based on its types and biodegradability. Segregating small nonbiodegradable waste from a heterogeneous mix of waste is a very big challenge. This letter proposes a rapid and efficient system to tackle this challenge where the system uses a spectroscopy sensor to collect information from the waste object and an algorithm to classify the nonbiodegradable waste materials from this heterogeneous mix of waste. Samples belonging to three object classes, namely, plastics, paper/ cardboard, and organic waste, were considered for testing the system, which uses regression model, confusion matrix, and an optimization technique to reduce error and obtain the best output closest to the ideal solution. This system gives the best output at 705 nm of wavelength with threshold values of 40.65 and 25.04. If the sensor output for a particular sample lies between 40.65 and 25.04, then it is a nonbiodegradable waste, whereas if the value lies above 40.65 or below 25.04, then it is a biodegradable waste. The experimental results demonstrate that the proposed system with the algorithm satisfactorily classifies the waste into biodegradable and nonbiodegradable waste.
- 12 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (8) , 1-4
Segregation of Municipal Solid Waste Based on Their Biodegradability Using Spectroscopy Sensor
The world today is facing a colossal increase in environmental pollution and degradation, resulting in ecological imbalance due to urbanization and development of smart cities. This necessitates the requirement for a robust waste management system, which can properly segregate waste based on its types and biodegradability. Segregating small nonbiodegradable waste from a heterogeneous mix of waste is a very big challenge. This letter proposes a rapid and efficient system to tackle this challenge where the system uses a spectroscopy sensor to collect information from the waste object and an algorithm to classify the nonbiodegradable waste materials from this heterogeneous mix of waste. Samples belonging to three object classes, namely, plastics, paper/ cardboard, and organic waste, were considered for testing the system, which uses regression model, confusion matrix, and an optimization technique to reduce error and obtain the best output closest to the ideal solution. This system gives the best output at 705 nm of wavelength with threshold values of 40.65 and 25.04. If the sensor output for a particular sample lies between 40.65 and 25.04, then it is a nonbiodegradable waste, whereas if the value lies above 40.65 or below 25.04, then it is a biodegradable waste. The experimental results demonstrate that the proposed system with the algorithm satisfactorily classifies the waste into biodegradable and nonbiodegradable waste.